  "id": 1159,
  "url": "https://nnemf.org/research/1159-comparison-of-elf-emfs-stimulation-with-current-stimulation",
  "title": "Comparison of ELF-EMFs stimulation with current stimulation on the regulation of LTP of SC-CA1 synapses in young rat hippocampus",
  "authors": [],
  "journal": "International journal of radiation biology",
  "year": "2021",
  "doi": "10.1080/09553002.2021.1928781",
  "pmid": "33970763",
  "abstract": "Comparison of ELF-EMFs stimulation with current stimulation on the regulation of LTP of SC-CA1 synapses in young rat hippocampus Yu Zheng, Wenjun Zhao, Xiaoxu Ma, Lei Dong, Lei Tian, Mei Zhou. Comparison of ELF-EMFs stimulation with current stimulation on the regulation of LTP of SC-CA1 synapses in young rat hippocampus. Int J Radiat Biol. 2021 May 10;1-21. doi: 10.1080/09553002.2021.1928781. Abstract Background: Long-term potentiation (LTP) is an important functional indicator for studying synaptic plasticity. Extremely low frequency electromagnetic fields (ELF-EMFs) are a physical means to regulate LTP. Time-varying magnetic fields induce induced currents. It is unknown which of the two parameters is the key factor when LTP is regulated by the magnetic field.New Method: A method is proposed for calculating the current value induced by ELF-EMFs. Then, a comparison of ELF-EMFs stimulation (100 Hz/2 mT and 200 Hz/2 mT) with current stimulation (0.1 μA and 0.2 μA) on the regulation of theta-burst or high-frequency stimulation (TBS/HFS)-LTP was performed. Results: The LTP after ELF-EMFs and μA current regulation was significantly reduced compared with the corresponding value in the control group. The regulatory effect of 100 Hz/2 mT ELF-EMFs on LTP was stronger than 200 Hz/2 mT. However, the regulatory level of the currents (0.1 μA, 0.2 μA) was similar; the effect of 0.1 μA current was similar to that of 100 Hz/2 mT ELF-EMFs, while 0.2 μA had a stronger regulatory effect than that of 200 Hz/2 mT on HFS-LTP.Comparison with Existing Methods: Most of the existing methods were used to calculate the induced current in human models, while a calculation model of the induced current in the rat brain slice induced by ELF-EMFs was established in this work, which is more accurate than the existing methods. Conclusions: This work demonstrated that both current and ELF EMFs stimulation reduced LTP. However, their effect was not exactly the same, indicating that the regulatory effect of ELF-EMFs on LTP is not entirely deriving from the induced current, since its magnetic mechanism might have played a certain role. https://pubmed.ncbi.nlm.nih.gov/33970763/",
  "effect": "harm",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "harm",
    "evidenceLabel": "Low",
    "population": "Young rat hippocampus (SC-CA1 synapses; brain slice model implied)",
    "sampleSize": "—",
    "exposure": "ELF <1 MHz",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "Compared with control, LTP after ELF-EMF stimulation (100 Hz/2 mT; 200 Hz/2 mT) and after microampere current stimulation (0.1 μA; 0.2 μA) was significantly reduced. The 100 Hz/2 mT ELF-EMF effect on LTP was stronger than 200 Hz/2 mT; current effects at 0.1 and 0.2 μA were described as similar overall, with 0.1 μA similar to 100 Hz/2 mT and 0.2 μA stronger than 200 Hz/2 mT for HFS-LTP.",
    "outcomes": [
      "Long-term potentiation (LTP) of SC-CA1 synapses",
      "TBS-LTP",
      "HFS-LTP",
      "Induced current calculation/modeling in rat brain slice"
    ],
    "limitations": [
      "Sample size not reported in provided abstract/metadata",
      "Exposure duration and detailed experimental conditions not reported in provided abstract/metadata",
      "Animal/brain-slice findings may not generalize to humans"
    ],
    "keywords": [
      "ELF-EMF",
      "extremely low frequency",
      "magnetic field",
      "100 Hz",
      "200 Hz",
      "2 mT",
      "induced current",
      "0.1 μA",
      "0.2 μA",
      "hippocampus",
      "SC-CA1",
      "synaptic plasticity",
      "long-term potentiation",
      "TBS",
      "HFS"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": \"laboratory stimulation (magnetic field) and induced/current stimulation\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"Young rat hippocampus (SC-CA1 synapses; brain slice model implied)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Long-term potentiation (LTP) of SC-CA1 synapses\",\n    \"TBS-LTP\",\n    \"HFS-LTP\",\n    \"Induced current calculation/modeling in rat brain slice\"\n  ],\n  \"main_findings\": \"Compared with control, LTP after ELF-EMF stimulation (100 Hz/2 mT; 200 Hz/2 mT) and after microampere current stimulation (0.1 μA; 0.2 μA) was significantly reduced. The 100 Hz/2 mT ELF-EMF effect on LTP was stronger than 200 Hz/2 mT; current effects at 0.1 and 0.2 μA were described as similar overall, with 0.1 μA similar to 100 Hz/2 mT and 0.2 μA stronger than 200 Hz/2 mT for HFS-LTP.\",\n  \"effect_direction\": \"harm\",\n  \"limitations\": [\n    \"Sample size not reported in provided abstract/metadata\",\n    \"Exposure duration and detailed experimental conditions not reported in provided abstract/metadata\",\n    \"Animal/brain-slice findings may not generalize to humans\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"ELF-EMF\",\n    \"extremely low frequency\",\n    \"magnetic field\",\n    \"100 Hz\",\n    \"200 Hz\",\n    \"2 mT\",\n    \"induced current\",\n    \"0.1 μA\",\n    \"0.2 μA\",\n    \"hippocampus\",\n    \"SC-CA1\",\n    \"synaptic plasticity\",\n    \"long-term potentiation\",\n    \"TBS\",\n    \"HFS\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"mechanisms-neurophysiology\",\n      \"weight\": 0.86,\n      \"reason\": \"Assesses ELF-EMF and current stimulation effects on hippocampal LTP (synaptic plasticity mechanism).\"\n    },\n    {\n      \"slug\": \"elf-emf\",\n      \"weight\": 0.8,\n      \"reason\": \"Uses extremely low frequency magnetic fields (100–200 Hz, 2 mT) and compares to induced/current stimulation.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/33970763/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=1159",