  "id": 1175,
  "url": "https://nnemf.org/research/1175-activation-of-matrix-metalloproteinases-and-foxo3a-in-hacat",
  "title": "Activation of matrix metalloproteinases and FoxO3a in HaCaT keratinocytes by radiofrequency electromagnetic field exposure",
  "authors": [],
  "journal": "",
  "year": "2021",
  "doi": "10.1038/s41598-021",
  "pmid": null,
  "abstract": "Activation of matrix metalloproteinases and FoxO3a in HaCaT keratinocytes by radiofrequency electromagnetic field exposure Ju Hwan Kim, Dong-Jun Kang, Jun-Sang Bae, Jai Hyuen Lee, Sangbong Jeon, Hyung-Do Choi, Nam Kim, Hyung- Gun Kim, Hak Rim Kim. Activation of matrix metalloproteinases and FoxO3a in HaCaT keratinocytes by radiofrequency electromagnetic field exposure. Sci Rep. 2021 Apr 7;11(1):7680. doi: 10.1038/s41598-021- 87263-2. Abstract As the skin is the largest body organ and critically serves as a barrier, it is frequently exposed and could be physiologically affected by radiofrequency electromagnetic field (RF-EMF) exposure. In this study, we found that 1760 MHz RF-EMF (4.0 W/kg specific absorption rate for 2 h/day during 4 days) exposure could induce intracellular reactive oxygen species (ROS) production in HaCaT human keratinocytes using 2',7'- dichlorofluorescin diacetate fluorescent probe analysis. However, cell growth and viability were unaffected by RF-EMF exposure. Since oxidative stress in the skin greatly influences the skin-aging process, we analyzed the skin senescence-related factors activated by ROS generation. Matrix metalloproteinases 1, 3, and 7 (MMP1, MMP3, and MMP7), the main skin wrinkle-related proteins, were significantly increased in HaCaT cells after RF- EMF exposure. Additionally, the gelatinolytic activities of secreted MMP2 and MMP9 were also increased by RF- EMF exposure. FoxO3a (Ser318/321) and ERK1/2 (Thr 202/Tyr 204) phosphorylation levels were significantly increased by RF-EMF exposure. However, Bcl2 and Bax expression levels were not significantly changed, indicating that the apoptotic pathway was not activated in keratinocytes following RF-EMF exposure. In summary, our findings show that exposure to 1760 MHz RF-EMF induces ROS generation, leading to MMP activation and FoxO3a and ERK1/2 phosphorylation. These data suggest that RF-EMF exposure induces cellular senescence of skin cells through ROS induction in HaCaT human keratinocytes. Conclusion In conclusion, exposure to 1760 MHz RF-EMF at 4 W/kg SAR induced intracellular ROS generation, which then stimulated MMPs (MMP1, 2, 3, 7, and 9) and activated the ERK1/2 (phospho-ERK1/2) and FoxO3a (phospho- FoxO3a) signaling pathways in HaCaT cells. Our results suggest that these changes induced by RF-EMF exposure would contribute to skin-aging processes. : https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8027011/",
  "effect": "harm",
  "evidence": "low",
  "extraction": {
    "studyType": "in_vitro",
    "studyTypeLabel": "In vitro study",
    "effectDirection": "harm",
    "evidenceLabel": "Low",
    "population": "HaCaT human keratinocytes",
    "sampleSize": "—",
    "exposure": "RF · 1760 MHz · 4 W/kg · 2 h/day during 4 days",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "Exposure to 1760 MHz RF-EMF (SAR 4.0 W/kg; 2 h/day for 4 days) increased intracellular ROS in HaCaT keratinocytes, increased MMP1/3/7 levels and increased gelatinolytic activity of secreted MMP2 and MMP9, and increased phosphorylation of FoxO3a and ERK1/2. Cell growth/viability were unaffected and Bcl2/Bax expression was not significantly changed.",
    "outcomes": [
      "Intracellular reactive oxygen species (ROS) production",
      "Cell growth",
      "Cell viability",
      "MMP1",
      "MMP3",
      "MMP7 levels",
      "Gelatinolytic activity of secreted MMP2 and MMP9",
      "FoxO3a (Ser318/321) phosphorylation",
      "ERK1/2 (Thr202/Tyr204) phosphorylation",
      "Bcl2 expression",
      "Bax expression",
      "Apoptotic pathway activation",
      "Cellular senescence/skin-aging related factors"
    ],
    "limitations": [],
    "keywords": [
      "RF-EMF",
      "1760 MHz",
      "specific absorption rate",
      "SAR",
      "HaCaT",
      "keratinocytes",
      "ROS",
      "oxidative stress",
      "matrix metalloproteinases",
      "MMP1",
      "MMP2",
      "MMP3",
      "MMP7",
      "MMP9",
      "FoxO3a",
      "ERK1/2",
      "skin aging",
      "cellular senescence"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"in_vitro\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": null,\n    \"frequency_mhz\": 1760,\n    \"sar_wkg\": 4,\n    \"duration\": \"2 h/day during 4 days\"\n  },\n  \"population\": \"HaCaT human keratinocytes\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Intracellular reactive oxygen species (ROS) production\",\n    \"Cell growth\",\n    \"Cell viability\",\n    \"MMP1, MMP3, MMP7 levels\",\n    \"Gelatinolytic activity of secreted MMP2 and MMP9\",\n    \"FoxO3a (Ser318/321) phosphorylation\",\n    \"ERK1/2 (Thr202/Tyr204) phosphorylation\",\n    \"Bcl2 expression\",\n    \"Bax expression\",\n    \"Apoptotic pathway activation\",\n    \"Cellular senescence/skin-aging related factors\"\n  ],\n  \"main_findings\": \"Exposure to 1760 MHz RF-EMF (SAR 4.0 W/kg; 2 h/day for 4 days) increased intracellular ROS in HaCaT keratinocytes, increased MMP1/3/7 levels and increased gelatinolytic activity of secreted MMP2 and MMP9, and increased phosphorylation of FoxO3a and ERK1/2. Cell growth/viability were unaffected and Bcl2/Bax expression was not significantly changed.\",\n  \"effect_direction\": \"harm\",\n  \"limitations\": [],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"RF-EMF\",\n    \"1760 MHz\",\n    \"specific absorption rate\",\n    \"SAR\",\n    \"HaCaT\",\n    \"keratinocytes\",\n    \"ROS\",\n    \"oxidative stress\",\n    \"matrix metalloproteinases\",\n    \"MMP1\",\n    \"MMP2\",\n    \"MMP3\",\n    \"MMP7\",\n    \"MMP9\",\n    \"FoxO3a\",\n    \"ERK1/2\",\n    \"skin aging\",\n    \"cellular senescence\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8027011/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=1175",
  "updated": "2026-02-10 11:41:40"
}