  "id": 1397,
  "url": "https://nnemf.org/research/1397-radiofrequency-exposure-in-the-neonatal-medium-care-unit",
  "title": "Radiofrequency exposure in the Neonatal Medium Care Unit I",
  "authors": [],
  "journal": "",
  "year": "2017",
  "doi": null,
  "pmid": null,
  "abstract": "Radiofrequency exposure in the Neonatal Medium Care Unit I. Calvente, A. Vázquez-Pérez, M.F. Fernández, M.I. Núñez, A. Múñoz-Hoyos. Radiofrequency exposure in the Neonatal Medium Care Unit. Environmental Research, 152:66-72. January 2017. Highlights * The increasing use of RF-EMF suggests an urgent need for more research in this field. * Health consequences of RF-EMF exposure on infants are not well known. * Description of RF-EMF exposure is vital in further study mechanisms on infant health. * Considering newborns vulnerability, it is wise to adopt a prudent avoidance strategy. Abstract The aims of this study were to characterize electromagnetic fields of radiofrequency (RF-EMF) levels generated in a Neonatal Medium Care Unit and to analyze RF-EMF levels inside unit's incubators. Spot and long-term measurements were made with a dosimeter. The spot measurement mean was 1.51±0.48 V/m. Higher values were found in the proximity to the window and to the incubator evaluated. Mean field strength for the entire period of 17 h was 0.81 (±0.07) V/m and the maximum value was 1.58 V/m for long-term RF-EMF measurements in the incubator. Values found during the night period were higher than those found during the day period. It is important to consider RF-EMF exposure levels in neonatal care units, due to some evidence of adverse health effects found in children and adults. Characterization of RF-EMF exposure may be important to further investigate the mechanisms and underlying effects of electromagnetic fields (EMF) on infant health. A prudent avoidance strategy should be adopted because newborns are at a vulnerable stage of development and the actual impact of EMF on premature infants is unknown. http://www.sciencedirect.com/science/article/pii/S0013935116306570",
  "effect": "unclear",
  "evidence": "low",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "unclear",
    "evidenceLabel": "Low",
    "population": "Premature/newborn infants in a Neonatal Medium Care Unit (incubator measurements)",
    "sampleSize": "—",
    "exposure": "RF neonatal medium care unit / incubator environment · spot measurements and long-term measurements over 17 h",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Spot measurements had a mean field strength of 1.51±0.48 V/m, with higher values near a window and near the incubator evaluated. Long-term measurements inside an incubator over 17 h had a mean of 0.81±0.07 V/m and a maximum of 1.58 V/m; night values were higher than day values.",
    "outcomes": [
      "RF-EMF electric field strength (V/m) in neonatal care unit",
      "RF-EMF electric field strength (V/m) inside incubators",
      "Day vs night RF-EMF level differences"
    ],
    "limitations": [
      "No health outcomes were measured",
      "study focused on exposure characterization only.",
      "RF frequency details were not reported in the provided abstract.",
      "Sample size/number of units/incubators measured was not stated in the provided abstract."
    ],
    "keywords": [
      "RF-EMF",
      "radiofrequency exposure",
      "neonatal medium care unit",
      "incubator",
      "dosimeter",
      "spot measurements",
      "long-term measurements",
      "electric field strength",
      "V/m",
      "day-night variation"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"neonatal medium care unit / incubator environment\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"spot measurements and long-term measurements over 17 h\"\n  },\n  \"population\": \"Premature/newborn infants in a Neonatal Medium Care Unit (incubator measurements)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"RF-EMF electric field strength (V/m) in neonatal care unit\",\n    \"RF-EMF electric field strength (V/m) inside incubators\",\n    \"Day vs night RF-EMF level differences\"\n  ],\n  \"main_findings\": \"Spot measurements had a mean field strength of 1.51±0.48 V/m, with higher values near a window and near the incubator evaluated. Long-term measurements inside an incubator over 17 h had a mean of 0.81±0.07 V/m and a maximum of 1.58 V/m; night values were higher than day values.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No health outcomes were measured; study focused on exposure characterization only.\",\n    \"RF frequency details were not reported in the provided abstract.\",\n    \"Sample size/number of units/incubators measured was not stated in the provided abstract.\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"RF-EMF\",\n    \"radiofrequency exposure\",\n    \"neonatal medium care unit\",\n    \"incubator\",\n    \"dosimeter\",\n    \"spot measurements\",\n    \"long-term measurements\",\n    \"electric field strength\",\n    \"V/m\",\n    \"day-night variation\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"exposure-assessment\",\n      \"weight\": 0.9,\n      \"reason\": \"Study characterizes RF-EMF levels in a neonatal care unit and inside incubators using spot and long-term dosimetry.\"\n    },\n    {\n      \"slug\": \"medical-settings\",\n      \"weight\": 0.6,\n      \"reason\": \"Measurements were conducted in a neonatal care (hospital) environment.\"\n    }\n  ]\n}"
  },