  "id": 1400,
  "url": "https://nnemf.org/research/1400-numerical-compliance-testing-of-human-exposure-to-electromagnetic",
  "title": "Numerical compliance testing of human exposure to electromagnetic radiation from smart-watches",
  "authors": [],
  "journal": "",
  "year": "2016",
  "doi": null,
  "pmid": null,
  "abstract": "Numerical compliance testing of human exposure to electromagnetic radiation from smart-watches Hong SE, Lee AK, Kwon JH, Pack JK. Numerical compliance testing of human exposure to electromagnetic radiation from smart-watches. Phys Med Biol. 2016 Oct 7;61(19):6975-6992. Abstract In this study, we investigated the electromagnetic dosimetry for smart-watches. At present, the standard for compliance testing of body-mounted and handheld devices specifies the use of a flat phantom to provide conservative estimates of the peak spatial-averaged specific absorption rate (SAR). This means that the estimated SAR using a flat phantom should be higher than the SAR in the exposure part of an anatomical human-body model. To verify this, we numerically calculated the SAR for a flat phantom and compared it with the numerical calculation of the SAR for four anatomical human-body models of different ages. The numerical analysis was performed using the finite difference time domain method (FDTD). The smart-watch models were used in the three antennas: the shorted planar inverted-F antenna (PIFA), loop antenna, and monopole antenna. Numerical smart-watch models were implemented for cellular commutation and wireless local-area network operation at 835, 1850, and 2450 MHz. The peak spatial-averaged SARs of the smart-watch models are calculated for the flat phantom and anatomical human-body model for the wrist-worn and next to mouth positions. The results show that the flat phantom does not provide a consistent conservative SAR estimate. We concluded that the difference in the SAR results between an anatomical human-body model and a flat phantom can be attributed to the different phantom shapes and tissue structures. https://www.ncbi.nlm.nih.gov/pubmed/?term=27648862 These results show that the flat phantom does not always yield a conservative estimate of the spatial peak SAR for the implemented smart-watch model at all exposure scenarios. A conservative exposure estimate for limb- worn device can be obtained by applying a multiplication factor between 1.1 and 2.6 to conventionally estimated values.",
  "effect": "unclear",
  "evidence": "low",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "unclear",
    "evidenceLabel": "Low",
    "population": "—",
    "sampleSize": "—",
    "exposure": "RF 1000–3000 MHz",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "Using FDTD simulations at 835, 1850, and 2450 MHz for smart-watch antenna models, the flat phantom did not provide a consistent conservative estimate of spatial peak SAR compared with four anatomical human-body models across wrist-worn and next-to-mouth scenarios. The authors suggest a conservative exposure estimate for limb-worn devices could be obtained by applying a multiplication factor between 1.1 and 2.6 to conventionally estimated values.",
    "outcomes": [
      "Peak spatial-averaged specific absorption rate (SAR)",
      "Comparison of SAR estimates between flat phantom and anatomical human-body models",
      "Conservativeness of compliance testing approach for body-mounted/handheld devices"
    ],
    "limitations": [
      "Numerical study (simulation-based) rather than measurements in humans",
      "Specific results depend on modeled antenna types (PIFA",
      "loop",
      "monopole)",
      "frequencies (835/1850/2450 MHz)",
      "and exposure scenarios (wrist-worn",
      "next to mouth)",
      "Details of anatomical models (beyond age differences) and device parameters are not provided in the abstract"
    ],
    "keywords": [
      "smart-watch",
      "dosimetry",
      "SAR",
      "flat phantom",
      "anatomical human-body model",
      "FDTD",
      "PIFA",
      "loop antenna",
      "monopole antenna",
      "835 MHz",
      "1850 MHz",
      "2450 MHz",
      "compliance testing"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"smart-watch\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Peak spatial-averaged specific absorption rate (SAR)\",\n    \"Comparison of SAR estimates between flat phantom and anatomical human-body models\",\n    \"Conservativeness of compliance testing approach for body-mounted/handheld devices\"\n  ],\n  \"main_findings\": \"Using FDTD simulations at 835, 1850, and 2450 MHz for smart-watch antenna models, the flat phantom did not provide a consistent conservative estimate of spatial peak SAR compared with four anatomical human-body models across wrist-worn and next-to-mouth scenarios. The authors suggest a conservative exposure estimate for limb-worn devices could be obtained by applying a multiplication factor between 1.1 and 2.6 to conventionally estimated values.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"Numerical study (simulation-based) rather than measurements in humans\",\n    \"Specific results depend on modeled antenna types (PIFA, loop, monopole), frequencies (835/1850/2450 MHz), and exposure scenarios (wrist-worn, next to mouth)\",\n    \"Details of anatomical models (beyond age differences) and device parameters are not provided in the abstract\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"smart-watch\",\n    \"dosimetry\",\n    \"SAR\",\n    \"flat phantom\",\n    \"anatomical human-body model\",\n    \"FDTD\",\n    \"PIFA\",\n    \"loop antenna\",\n    \"monopole antenna\",\n    \"835 MHz\",\n    \"1850 MHz\",\n    \"2450 MHz\",\n    \"compliance testing\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"wearables\",\n      \"weight\": 0.9,\n      \"reason\": \"Study evaluates RF exposure/SAR from smart-watches (wearable device).\"\n    },\n    {\n      \"slug\": \"sar-compliance-testing\",\n      \"weight\": 0.85,\n      \"reason\": \"Focuses on compliance testing methodology and whether flat phantoms provide conservative SAR estimates.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://www.ncbi.nlm.nih.gov/pubmed/?term=27648862",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=1400",
  "updated": "2026-02-10 12:00:18"
}