  "id": 142,
  "url": "https://nnemf.org/research/142-iec-ieee-draft-international-standard-assessment-methods-of",
  "title": "IEC/IEEE Draft International Standard - Assessment methods of the human exposure to electric and magnetic fields from wireless power transfer systems IEC",
  "authors": [],
  "journal": "",
  "year": "2024",
  "doi": null,
  "pmid": null,
  "abstract": "IEC/IEEE Draft International Standard - Assessment methods of the human exposure to electric and magnetic fields from wireless power transfer systems IEC/IEEE Draft International Standard - Assessment methods of the human exposure to electric and magnetic fields from wireless power transfer systems - models, instrumentation, measurement and numerical methods and procedures (Frequency range of 1 kHz to 30 MHz). IEC/IEEE P63184/FDIS, June 2024 , vol., no., pp.1-153, 26 June 2024. Abstract The objective of this document is to specify the assessment methods to evaluate compliance of stationary and dynamic wireless power transfer (WPT) systems with electromagnetic human exposure guidelines (specific absorption rate (SAR), internal electric fields, or current density including contact currents). The frequency range covered by this document is from 1 kHz to 30 MHz. This version of the standard focuses on exposures from inductive WPT systems. Future versions will consider extended guidance for assessments of exposure from capacitive WPT systems. https://ieeexplore.ieee.org/document/10576682",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "policy",
    "studyTypeLabel": "policy",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "RF 1–100 MHz",
    "confidencePct": "74",
    "peerReviewed": "unknown",
    "mainFindings": "This draft international standard specifies assessment methods (models, instrumentation, measurement, numerical methods and procedures) to evaluate compliance of stationary and dynamic wireless power transfer systems with electromagnetic human exposure guidelines, including SAR, internal electric fields, and current density/contact currents, over 1 kHz to 30 MHz. It focuses on inductive WPT exposures; future versions are intended to extend guidance for capacitive WPT exposure assessments.",
    "outcomes": [
      "Compliance assessment methods for human exposure guidelines",
      "Specific absorption rate (SAR)",
      "Internal electric fields",
      "Current density",
      "Contact currents"
    ],
    "limitations": [
      "Document is a draft international standard (not a health-effects study)",
      "Focuses on inductive WPT systems",
      "capacitive WPT systems deferred to future versions"
    ],
    "keywords": [
      "IEC/IEEE",
      "international standard",
      "human exposure assessment",
      "wireless power transfer",
      "WPT",
      "inductive",
      "compliance",
      "SAR",
      "internal electric fields",
      "current density",
      "contact currents",
      "1 kHz to 30 MHz"
    ],
    "hubs": [
      {
        "slug": "who-icnirp",
        "weight": "0.7",
        "reason": "Standard addresses compliance with electromagnetic human exposure guidelines (e.g., SAR, internal electric fields, current density/contact currents)."
      }
    ],
    "raw": "{\n  \"study_type\": \"policy\",\n  \"exposure\": {\n    \"band\": \"unknown\",\n    \"source\": \"wireless power transfer (WPT) systems\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Compliance assessment methods for human exposure guidelines\",\n    \"Specific absorption rate (SAR)\",\n    \"Internal electric fields\",\n    \"Current density\",\n    \"Contact currents\"\n  ],\n  \"main_findings\": \"This draft international standard specifies assessment methods (models, instrumentation, measurement, numerical methods and procedures) to evaluate compliance of stationary and dynamic wireless power transfer systems with electromagnetic human exposure guidelines, including SAR, internal electric fields, and current density/contact currents, over 1 kHz to 30 MHz. It focuses on inductive WPT exposures; future versions are intended to extend guidance for capacitive WPT exposure assessments.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"Document is a draft international standard (not a health-effects study)\",\n    \"Focuses on inductive WPT systems; capacitive WPT systems deferred to future versions\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"unknown\",\n  \"keywords\": [\n    \"IEC/IEEE\",\n    \"international standard\",\n    \"human exposure assessment\",\n    \"wireless power transfer\",\n    \"WPT\",\n    \"inductive\",\n    \"compliance\",\n    \"SAR\",\n    \"internal electric fields\",\n    \"current density\",\n    \"contact currents\",\n    \"1 kHz to 30 MHz\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"who-icnirp\",\n      \"weight\": 0.55,\n      \"reason\": \"Standard addresses compliance with electromagnetic human exposure guidelines (e.g., SAR, internal electric fields, current density/contact currents).\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://ieeexplore.ieee.org/document/10576682",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=142",
  "updated": "2026-02-10 09:49:24"
}