Share

Electromagnetic Shielding of Building Walls: From Roman times to the present age

PAPERmanual2016exposure assessmentEffect: unclearEvidence: Insufficient

Abstract

Electromagnetic Shielding of Building Walls: From Roman times to the present age Davide Micheli, Paolo Gianola, Giorgio Bertin, Andrea Delfini, Roberto Pastore, Mario Marchetti, Roberto Diana. Electromagnetic Shielding of Building Walls: From Roman times to the present age. IEEE Antennas and Propagation Magazine. 58(5). Oct. 2016. Abstract We have investigated the electromagnetic (EM) shielding effectiveness (SE) of building walls built in different ages. The measurements were carried out in the city of Rome, analyzing different building typologies from Roman Empire historical ruins up to modern reinforced concrete and steel/glass buildings. The method consisted of a measurement performed by means of a portable two-port vector network analyzer (VNA) connected to a couple of light antennas located in opposite positions with respect to the middle wall. The explored frequencies were in the range of 0.7-5.0 GHz, which many countries have currently adopted for mobile-phone radio access network (RAN) and satellite positioning services. The SE measurements showed values of up to 100 dB, and the analysis of the results showed that ancient Romans building walls and steel/glass building structures have the highest shielding capability. A numerical simulation of the outdoor-to-indoor transition attenuation and a statistical analysis of the signal code power in the live RAN of Telecom Italia integrate the discussion of the results. ieeexplore.ieee.org

AI evidence extraction

At a glance
Study type
exposure assessment
Effect direction
unclear
Population
—
Sample size
—
Exposure
RF >3000 MHz
Evidence strength
Insufficient
Confidence: 74% · Peer-reviewed: yes

Main findings

Measurements in Rome across building typologies (from Roman ruins to modern reinforced concrete and steel/glass buildings) over 0.7–5.0 GHz found shielding effectiveness values up to 100 dB. The analysis reported that ancient Roman building walls and steel/glass building structures had the highest shielding capability.

Outcomes measured

  • Shielding effectiveness (SE) of building walls
  • Outdoor-to-indoor transition attenuation
  • Statistical analysis of signal code power in a live mobile-phone RAN
View raw extracted JSON
{
  "study_type": "exposure_assessment",
  "exposure": {
    "band": "RF",
    "source": "building walls (shielding/attenuation of outdoor-to-indoor signals)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "Shielding effectiveness (SE) of building walls",
    "Outdoor-to-indoor transition attenuation",
    "Statistical analysis of signal code power in a live mobile-phone RAN"
  ],
  "main_findings": "Measurements in Rome across building typologies (from Roman ruins to modern reinforced concrete and steel/glass buildings) over 0.7–5.0 GHz found shielding effectiveness values up to 100 dB. The analysis reported that ancient Roman building walls and steel/glass building structures had the highest shielding capability.",
  "effect_direction": "unclear",
  "limitations": [],
  "evidence_strength": "insufficient",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "electromagnetic shielding",
    "shielding effectiveness",
    "building walls",
    "outdoor-to-indoor attenuation",
    "vector network analyzer",
    "0.7-5.0 GHz",
    "mobile-phone RAN",
    "Rome",
    "steel/glass buildings",
    "reinforced concrete"
  ],
  "suggested_hubs": [
    {
      "slug": "exposure-assessment",
      "weight": 0.86,
      "reason": "Direct measurements of RF shielding effectiveness and outdoor-to-indoor attenuation across building types in the 0.7–5.0 GHz range relevant to mobile networks."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 1439

Electromagnetic Shielding of Building Walls: From Roman times to the present age · Non-native EMF