Share

Comparison of Intraocular Pressure Changes Due to Exposure to Mobile Phone Electromagnetics Radiations in Normal and Glaucoma Eye

PAPERmanual2020OtherEffect: mixedEvidence: Low

Abstract

Comparison of Intraocular Pressure Changes Due to Exposure to Mobile Phone Electromagnetics Radiations in Normal and Glaucoma Eye Saeed Shokoohi-Rad, Mohammad-Rez Ansari, Fatemeh Sabzi, Rahim Saffari, Parisa Rajaei, Farshid Karimi. Comparison of Intraocular Pressure Changes Due to Exposure to Mobile Phone Electromagnetics Radiations in Normal and Glaucoma Eye. Middle East Afr J Ophthalmol. 2020 Apr 29;27(1):10-13. doi: 10.4103/meajo.MEAJO_20_19. DOI: 10.4103/meajo.MEAJO_20_19 Abstract Purpose: The aim of this study is to investigate the effects of electromagnetic waves (EMWs) emitted by a mobile phone on the intraocular pressure (IOP) in the eyeball. Methods: This quasi-experimental study was conducted on 166 eyes from 83 individuals in the 40-70 age range who referred to "Khatam-al-Anbia Hospital, Mashhad, Iran" in 2016. There were two groups of participants, and the first one consisted of 41 participants who had normal eyes, whereas the second one comprised 42 participants who suffered from open-angle glaucoma disease. The IOP in both groups was measured and recorded by a specialist before and after talking 5 min on the cellphone with the help of the Goldman method. Statistical analysis such as paired t-test and analysis of variance was performed and all tests are statistically significant at (P < 0.05). For this purpose, the SPSS software (version 16) was applied. Results: IOP in the glaucoma eye (42 eyes) ipsilateral to mobile phone before and after the intervention was 18.64 ± 6.7 and 23.53 ± 6.3, respectively (P < 0.001). However, IOP in the control group (41 eyes) ipsilateral to mobile phone before and after the intervention was 12.95 ± 3.5 and 13.39 ± 2.8, respectively (P = 0.063). IOP change in the opposite glaucomatous eye to mobile phone in glaucoma group (39 eyes) and normal group (44 eyes) was not significantly different before and after the phone call (P = 0.065 and P = 0.85, respectively). Conclusion: We found that the acute effects of EMWs emitted from the mobile phones can significantly increase the IOP in glaucoma eye, while such changes were not observed in normal eyes. : ncbi.nlm.nih.gov

AI evidence extraction

At a glance
Study type
Other
Effect direction
mixed
Population
Individuals aged 40–70 years referred to Khatam-al-Anbia Hospital, Mashhad, Iran (2016); normal eyes vs open-angle glaucoma
Sample size
83
Exposure
mobile phone · 5 min phone call
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

In the glaucoma group, IOP in the eye ipsilateral to the mobile phone increased from 18.64 ± 6.7 to 23.53 ± 6.3 after a 5-minute phone call (P < 0.001). In the normal-eye group, ipsilateral IOP change was not statistically significant (12.95 ± 3.5 to 13.39 ± 2.8; P = 0.063), and contralateral eyes in both groups did not show significant pre/post differences.

Outcomes measured

  • Intraocular pressure (IOP)

Limitations

  • Quasi-experimental design (non-randomized)
  • Exposure characteristics (e.g.
  • phone model
  • frequency
  • SAR
  • distance) not reported in abstract
  • Short-term/acute exposure only (5 minutes)
  • Single-center sample
  • generalizability unclear
  • Outcome assessment timing limited to immediately before/after call
View raw extracted JSON
{
  "study_type": "other",
  "exposure": {
    "band": null,
    "source": "mobile phone",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "5 min phone call"
  },
  "population": "Individuals aged 40–70 years referred to Khatam-al-Anbia Hospital, Mashhad, Iran (2016); normal eyes vs open-angle glaucoma",
  "sample_size": 83,
  "outcomes": [
    "Intraocular pressure (IOP)"
  ],
  "main_findings": "In the glaucoma group, IOP in the eye ipsilateral to the mobile phone increased from 18.64 ± 6.7 to 23.53 ± 6.3 after a 5-minute phone call (P < 0.001). In the normal-eye group, ipsilateral IOP change was not statistically significant (12.95 ± 3.5 to 13.39 ± 2.8; P = 0.063), and contralateral eyes in both groups did not show significant pre/post differences.",
  "effect_direction": "mixed",
  "limitations": [
    "Quasi-experimental design (non-randomized)",
    "Exposure characteristics (e.g., phone model, frequency, SAR, distance) not reported in abstract",
    "Short-term/acute exposure only (5 minutes)",
    "Single-center sample; generalizability unclear",
    "Outcome assessment timing limited to immediately before/after call"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "mobile phone",
    "electromagnetic waves",
    "electromagnetic radiation",
    "intraocular pressure",
    "glaucoma",
    "open-angle glaucoma",
    "Goldmann method",
    "acute exposure"
  ],
  "suggested_hubs": [
    {
      "slug": "rf-health-effects",
      "weight": 0.78,
      "reason": "Assesses acute health-related outcome (IOP) after mobile phone EMW exposure."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 1498

Comparison of Intraocular Pressure Changes Due to Exposure to Mobile Phone Electromagnetics Radiations in Normal and Glaucoma Eye · Non-native EMF