  "id": 1529,
  "url": "https://nnemf.org/research/1529-case-control-study-on-occupational-exposure-to-extremely",
  "title": "Case-control study on occupational exposure to extremely low-frequency electromagnetic fields and the association with acoustic neuroma",
  "authors": [],
  "journal": "Environmental research",
  "year": "2020",
  "doi": "10.1016/j.envres.2020.109621",
  "pmid": "32422481",
  "abstract": "Case-control study on occupational exposure to extremely low-frequency electromagnetic fields and the association with acoustic neuroma Carlberg M, Koppel T, Ahonen M, Hardell L. Case-control study on occupational exposure to extremely low- frequency electromagnetic fields and the association with acoustic neuroma. Environmental Research. Available online 7 May 2020, 109621 Highlights • Exposure to ELF-EMF has been classified as a possible human carcinogen by IARC. • Risk for acoustic neuroma was investigated for occupations with ELF-EMF exposure. • No increased risk for acoustic neuroma was found in any exposure category. Abstract Exposure to extremely low-frequency electromagnetic fields (ELF-EMF) was in 2002 classified as a possible human carcinogen, Group 2B, by the International Agency for Research on Cancer at WHO based on an increased risk for childhood leukemia. In case-control studies on brain and head tumours during 1997-2003 and 2007-2009 we assessed life-time occupations in addition to exposure to different agents. The INTEROCC ELF- EMF Job-Exposure Matrix was used for associating occupations with ELF-EMF exposure (μT) with acoustic neuroma. Cumulative exposure (μT-years), average exposure (μT) and maximum exposed job (μT) were calculated. No increased risk for acoustic neuroma was found in any category. For cumulative exposure in the highest exposure category 8.52+ μT years odds ratio (OR) = 1.2, 95 % confidence interval (CI) = 0.8-2.0, p linear trend = 0.37 was calculated. No statistically significant risks were found in the time windows 1-14 years, and 15+ years, respectively. In conclusion occupational ELF-EMF was not associated with an increased risk for acoustic neuroma. https://pubmed.ncbi.nlm.nih.gov/32422481/",
  "effect": "no_effect",
  "evidence": "low",
  "extraction": {
    "studyType": "case_control",
    "studyTypeLabel": "case control",
    "effectDirection": "no_effect",
    "evidenceLabel": "Low",
    "population": "—",
    "sampleSize": "—",
    "exposure": "ELF occupational · lifetime occupations; time windows 1–14 years and 15+ years",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "Using the INTEROCC ELF-EMF job-exposure matrix, no increased risk for acoustic neuroma was found in any exposure category. In the highest cumulative exposure category (8.52+ µT-years), OR was 1.2 (95% CI 0.8–2.0) with no significant linear trend (p=0.37), and no statistically significant risks were found in time windows 1–14 years and 15+ years.",
    "outcomes": [
      "acoustic neuroma"
    ],
    "limitations": [
      "Population characteristics and sample size not reported in the abstract.",
      "Exposure assessment based on a job-exposure matrix (INTEROCC) rather than individual measurements.",
      "Specific occupational categories and potential confounder adjustments not described in the abstract."
    ],
    "keywords": [
      "extremely low-frequency",
      "ELF-EMF",
      "occupational exposure",
      "job-exposure matrix",
      "INTEROCC",
      "acoustic neuroma",
      "case-control",
      "odds ratio"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Study evaluates occupational ELF-EMF exposure and acoustic neuroma risk using a job-exposure matrix."
      },
      {
        "slug": "who-icnirp",
        "weight": "0.7",
        "reason": "Abstract references IARC/WHO carcinogen classification context for ELF-EMF."
      }
    ],
    "raw": "{\n  \"study_type\": \"case_control\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": \"occupational\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"lifetime occupations; time windows 1–14 years and 15+ years\"\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"acoustic neuroma\"\n  ],\n  \"main_findings\": \"Using the INTEROCC ELF-EMF job-exposure matrix, no increased risk for acoustic neuroma was found in any exposure category. In the highest cumulative exposure category (8.52+ µT-years), OR was 1.2 (95% CI 0.8–2.0) with no significant linear trend (p=0.37), and no statistically significant risks were found in time windows 1–14 years and 15+ years.\",\n  \"effect_direction\": \"no_effect\",\n  \"limitations\": [\n    \"Population characteristics and sample size not reported in the abstract.\",\n    \"Exposure assessment based on a job-exposure matrix (INTEROCC) rather than individual measurements.\",\n    \"Specific occupational categories and potential confounder adjustments not described in the abstract.\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"extremely low-frequency\",\n    \"ELF-EMF\",\n    \"occupational exposure\",\n    \"job-exposure matrix\",\n    \"INTEROCC\",\n    \"acoustic neuroma\",\n    \"case-control\",\n    \"odds ratio\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.9,\n      \"reason\": \"Study evaluates occupational ELF-EMF exposure and acoustic neuroma risk using a job-exposure matrix.\"\n    },\n    {\n      \"slug\": \"who-icnirp\",\n      \"weight\": 0.35,\n      \"reason\": \"Abstract references IARC/WHO carcinogen classification context for ELF-EMF.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/32422481/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=1529",
  "updated": "2026-02-10 12:13:28"
}