Share

Whole-body exposures to radiofrequency-electromagnetic energy can cause DNA damage in mouse spermatozoa via an oxidative mechanism

PAPERmanual2019Animal studyEffect: mixedEvidence: Low

Abstract

Whole-body exposures to radiofrequency-electromagnetic energy can cause DNA damage in mouse spermatozoa via an oxidative mechanism Houston BJ, Nixon B, McEwan KE, Martin JH, King BV, Aitken RJ, De Iuliis GN. Whole-body exposures to radiofrequency-electromagnetic energy can cause DNA damage in mouse spermatozoa via an oxidative mechanism. Sci Rep. 2019 Nov 25;9(1):17478. doi: 10.1038/s41598-019-53983-9. Abstract Artificially generated radiofrequency-electromagnetic energy (RF-EME) is now ubiquitous in our environment owing to the utilization of mobile phone and Wi-Fi based communication devices. While several studies have revealed that RF-EME is capable of eliciting biological stress, particularly in the context of the male reproductive system, the mechanistic basis of this biophysical interaction remains largely unresolved. To extend these studies, here we exposed unrestrained male mice to RF-EME generated via a dedicated waveguide (905 MHz, 2.2 W/kg) for 12 h per day for a period of 1, 3 or 5 weeks. The testes of exposed mice exhibited no evidence of gross histological change or elevated stress, irrespective of the RF-EME exposure regimen. By contrast, 5 weeks of RF- EME exposure adversely impacted the vitality and motility profiles of mature epididymal spermatozoa. These spermatozoa also experienced increased mitochondrial generation of reactive oxygen species after 1 week of exposure, with elevated DNA oxidation and fragmentation across all exposure periods. Notwithstanding these lesions, RF-EME exposure did not impair the fertilization competence of spermatozoa nor their ability to support early embryonic development. This study supports the utility of male germ cells as sensitive tools with which to assess the biological impacts of whole-body RF-EME exposure. : nature.com

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
mixed
Population
Unrestrained male mice
Sample size
—
Exposure
RF · 905 MHz · 2.2 W/kg · 12 h/day for 1, 3, or 5 weeks
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Male mice were exposed whole-body to RF-EME (905 MHz, 2.2 W/kg) 12 h/day for 1, 3, or 5 weeks. Testes showed no gross histological change or elevated stress across regimens, but 5 weeks exposure adversely affected sperm vitality and motility; sperm showed increased mitochondrial ROS after 1 week and elevated DNA oxidation and fragmentation across all exposure periods. Despite these lesions, fertilization competence and ability to support early embryonic development were not impaired.

Outcomes measured

  • Testis histology/gross histological change
  • Testicular stress (unspecified)
  • Sperm vitality
  • Sperm motility
  • Mitochondrial reactive oxygen species (ROS) generation in spermatozoa
  • Sperm DNA oxidation
  • Sperm DNA fragmentation
  • Fertilization competence
  • Support of early embryonic development

Limitations

  • Sample size not reported in provided abstract/metadata
  • Exposure source context (e.g.
  • phone/Wi-Fi vs laboratory generator) not specified beyond a dedicated waveguide
  • Details of outcome measurement methods and statistical results not provided in the abstract
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": "RF",
    "source": null,
    "frequency_mhz": 905,
    "sar_wkg": 2.2,
    "duration": "12 h/day for 1, 3, or 5 weeks"
  },
  "population": "Unrestrained male mice",
  "sample_size": null,
  "outcomes": [
    "Testis histology/gross histological change",
    "Testicular stress (unspecified)",
    "Sperm vitality",
    "Sperm motility",
    "Mitochondrial reactive oxygen species (ROS) generation in spermatozoa",
    "Sperm DNA oxidation",
    "Sperm DNA fragmentation",
    "Fertilization competence",
    "Support of early embryonic development"
  ],
  "main_findings": "Male mice were exposed whole-body to RF-EME (905 MHz, 2.2 W/kg) 12 h/day for 1, 3, or 5 weeks. Testes showed no gross histological change or elevated stress across regimens, but 5 weeks exposure adversely affected sperm vitality and motility; sperm showed increased mitochondrial ROS after 1 week and elevated DNA oxidation and fragmentation across all exposure periods. Despite these lesions, fertilization competence and ability to support early embryonic development were not impaired.",
  "effect_direction": "mixed",
  "limitations": [
    "Sample size not reported in provided abstract/metadata",
    "Exposure source context (e.g., phone/Wi-Fi vs laboratory generator) not specified beyond a dedicated waveguide",
    "Details of outcome measurement methods and statistical results not provided in the abstract"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "radiofrequency",
    "RF-EME",
    "whole-body exposure",
    "mouse",
    "spermatozoa",
    "DNA damage",
    "DNA fragmentation",
    "DNA oxidation",
    "oxidative stress",
    "reactive oxygen species",
    "male reproductive system",
    "905 MHz",
    "SAR 2.2 W/kg"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 1629

Whole-body exposures to radiofrequency-electromagnetic energy can cause DNA damage in mouse spermatozoa via an oxidative mechanism · Non-native EMF