Exposure To Extremely Low-Frequency Magnetic Fields In Low- And Middle-Income Countries: An Overview

PAPERmanualRadiation protection dosimetry2020systematic reviewEffect: unclearEvidence: Low

Abstract

Exposure To Extremely Low-Frequency Magnetic Fields In Low- And Middle-Income Countries: An Overview Dan Baaken, Daniel Wollschläger, Theodoros Samaras, Joachim Schüz , Isabelle Deltour. Exposure To Extremely Low-Frequency Magnetic Fields In Low- And Middle-Income Countries: An Overview. Radiat Prot Dosimetry. 2020 Nov 24;ncaa172. doi: 10.1093/rpd/ncaa172. Abstract To compare extremely low-frequency magnetic field (ELF-MF) exposure in the general population in low- and middle-income countries (LMICs) with high-income countries (HIC), we carried out a systematic literature search resulting in 1483 potentially eligible articles; however, only 25 studies could be included in the qualitative synthesis. Studies showed large heterogeneity in design, exposure environment and exposure assessment. Exposure assessed by outdoor spot measurements ranged from 0.03 to 4μT. Average exposure by indoor spot measurements in homes ranged from 0.02 to 0.4μT. Proportions of homes exposed to a threshold of ≥0.3μT were many times higher in LMICs compared to HIC. Based on the limited data available, exposure to ELF-MF in LMICs appeared higher than in HIC, but a direct comparison is hampered by a lack of representative and systematic monitoring studies. Representative measurement studies on residential exposure to ELF-MF are needed in LMICs together with better standardisation in the reporting. pubmed.ncbi.nlm.nih.gov

AI evidence extraction

At a glance
Study type
systematic review
Effect direction
unclear
Population
General population in low- and middle-income countries (LMICs), compared with high-income countries (HICs)
Sample size
25
Exposure
ELF <1 MHz
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

A systematic literature search identified 1483 potentially eligible articles, with 25 studies included in qualitative synthesis. Outdoor spot measurements ranged from 0.03 to 4 µT and average indoor spot measurements in homes ranged from 0.02 to 0.4 µT. The proportion of homes with exposure ≥0.3 µT was reported as many times higher in LMICs than in HICs; however, direct comparison was limited by lack of representative and systematic monitoring studies.

Outcomes measured

  • ELF magnetic field exposure levels (µT)
  • Proportion of homes above exposure threshold (≥0.3 µT)

Limitations

  • Only 25 studies could be included from 1483 potentially eligible articles
  • Large heterogeneity in study design
  • exposure environment
  • and exposure assessment
  • Lack of representative and systematic monitoring studies hampers direct LMIC vs HIC comparisons
  • Need for better standardisation in reporting
View raw extracted JSON
{
  "study_type": "systematic_review",
  "exposure": {
    "band": "ELF",
    "source": "general population (residential/outdoor spot measurements)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": "General population in low- and middle-income countries (LMICs), compared with high-income countries (HICs)",
  "sample_size": 25,
  "outcomes": [
    "ELF magnetic field exposure levels (µT)",
    "Proportion of homes above exposure threshold (≥0.3 µT)"
  ],
  "main_findings": "A systematic literature search identified 1483 potentially eligible articles, with 25 studies included in qualitative synthesis. Outdoor spot measurements ranged from 0.03 to 4 µT and average indoor spot measurements in homes ranged from 0.02 to 0.4 µT. The proportion of homes with exposure ≥0.3 µT was reported as many times higher in LMICs than in HICs; however, direct comparison was limited by lack of representative and systematic monitoring studies.",
  "effect_direction": "unclear",
  "limitations": [
    "Only 25 studies could be included from 1483 potentially eligible articles",
    "Large heterogeneity in study design, exposure environment, and exposure assessment",
    "Lack of representative and systematic monitoring studies hampers direct LMIC vs HIC comparisons",
    "Need for better standardisation in reporting"
  ],
  "evidence_strength": "low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "extremely low-frequency",
    "ELF-MF",
    "magnetic fields",
    "exposure assessment",
    "spot measurements",
    "residential exposure",
    "low- and middle-income countries",
    "LMIC",
    "high-income countries",
    "HIC",
    "systematic literature search"
  ],
  "suggested_hubs": [
    {
      "slug": "exposure-assessment",
      "weight": 0.86,
      "reason": "Focuses on measurement-based assessment of ELF magnetic field exposure (indoor/outdoor spot measurements) and reporting/standardisation issues."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 1636

Exposure To Extremely Low-Frequency Magnetic Fields In Low- And Middle-Income Countries: An Overview · Non-native EMF