  "id": 1640,
  "url": "https://nnemf.org/research/1640-environmental-radiofrequency-electromagnetic-field-levels-in-a-department",
  "title": "Environmental radiofrequency electromagnetic field levels in a department of pediatrics",
  "authors": [],
  "journal": "",
  "year": "2019",
  "doi": "10.1016/j.envres.2019.108894",
  "pmid": null,
  "abstract": "Environmental radiofrequency electromagnetic field levels in a department of pediatrics Besset D, Selmaoui B, Tourneux P, Leke A, Delanaud S, de Seze R, Stephan Blanchard E. Environmental radiofrequency electromagnetic field levels in a department of pediatrics. Environ Res. 2019 Nov 6:108894. doi: 10.1016/j.envres.2019.108894. Abstract Preterm neonates constitute a vulnerable population that is highly sensitive to its environment. Given the increased use of wireless communication devices (mobile and digital enhanced cordless telecommunications, WiFi networks, etc.), neonates hospitalized in a department of pediatrics are potentially exposed to radiofrequency electromagnetic fields (RF-EMF). Strikingly, data on RF-EMF levels in pediatric units have not previously been published. The objective of the present study was thus to quantify the RF-EMF levels in a 34-bed tertiary department of pediatrics with a neonatal critical care unit (NCCU) and a neonatal intensive care unit (NICU). To this end, we used triaxle antenna dosimeters to map the RF-EMF levels in the environment and to measure spot emissions from medical devices. In a first set of experiments, RF-EMF levels at 144 points in the staff area and in the children's rooms in the NCCU and NICU were evaluated over a 24-h period. In a second set of measurements performed in a Faraday chamber, we measured the RF-EMF levels emitted by the medical devices to which neonates are potentially exposed in the department of pediatrics. The RF-EMF levels were significantly higher in the NCCU than in the NICU (p < 0.05). Although the two units did not differ significantly with regard to the average maximum values, the single greatest value recorded in the NCCU (6 V/m GSM + UMTS 900 (UL) frequency band, in the staff area) was more than twice that recorded in the NICU (3.70 V/m in the UMTS 2100 (UL) frequency band, in the children's rooms). The NCCU and NICU did not differ significantly with regard to the time during which the RF-EMF level at each measurement point was more than two standard deviations above its mean. The RF-EMF level was significantly higher during the day than during the night (p < 0.001). The various medical devices used in the NICU did not emit detectable amounts of RF. Overall, RF-EMF levels in the NCCU and NICU were very low. It is probable that the RF-EMFs measured here were primarily generated by the parents' and staff members' activities, rather than by medical devices. However, a combination of low-level, chronic exposure with transient, elevated peak values in a vulnerable population of preterm neonates may be of particular concern. In a department of pediatrics, decreasing preterm neonates' exposure to RF-EMFs should primarily involve a limitation on the use of wireless communication devices by staff members and parents. https://www.ncbi.nlm.nih.gov/pubmed/31740038",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "Preterm neonates in a tertiary department of pediatrics (NCCU and NICU); environmental measurements in staff areas and children's rooms",
    "sampleSize": "—",
    "exposure": "RF wireless communication devices (mobile, DECT, WiFi) and medical devices (assessed) · 24-h measurements at 144 points; additional spot measurements in Faraday chamber",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "RF-EMF levels were significantly higher in the NCCU than in the NICU (p < 0.05), and higher during the day than during the night (p < 0.001). The greatest recorded value was 6 V/m (GSM+UMTS 900 UL) in the NCCU staff area versus 3.70 V/m (UMTS 2100 UL) in NICU children's rooms; medical devices tested in the NICU did not emit detectable RF. Overall, measured RF-EMF levels in both units were described as very low and were attributed primarily to parents’ and staff members’ wireless device use rather than medical devices.",
    "outcomes": [
      "Environmental RF-EMF levels (V/m) in NCCU and NICU",
      "Peak and average maximum RF-EMF values by unit and location",
      "Day vs night RF-EMF levels",
      "Detectable RF emissions from medical devices (Faraday chamber)"
    ],
    "limitations": [
      "Single-site study in one 34-bed tertiary pediatrics department",
      "Frequency bands and metrics beyond those explicitly reported are not detailed in the abstract",
      "No health outcomes assessed",
      "exposure characterization only"
    ],
    "keywords": [
      "RF-EMF",
      "pediatrics",
      "neonatal critical care unit",
      "neonatal intensive care unit",
      "preterm neonates",
      "environmental measurements",
      "dosimeters",
      "GSM",
      "UMTS",
      "WiFi",
      "DECT",
      "Faraday chamber"
    ],
    "hubs": [
      {
        "slug": "school-wi-fi",
        "weight": "0.7",
        "reason": "WiFi networks mentioned as a potential source, though setting is a hospital neonatal unit rather than a school."
      },
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Measurements include staff areas and suggest staff device use as a primary RF-EMF source."
      }
    ],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"wireless communication devices (mobile, DECT, WiFi) and medical devices (assessed)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"24-h measurements at 144 points; additional spot measurements in Faraday chamber\"\n  },\n  \"population\": \"Preterm neonates in a tertiary department of pediatrics (NCCU and NICU); environmental measurements in staff areas and children's rooms\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Environmental RF-EMF levels (V/m) in NCCU and NICU\",\n    \"Peak and average maximum RF-EMF values by unit and location\",\n    \"Day vs night RF-EMF levels\",\n    \"Detectable RF emissions from medical devices (Faraday chamber)\"\n  ],\n  \"main_findings\": \"RF-EMF levels were significantly higher in the NCCU than in the NICU (p < 0.05), and higher during the day than during the night (p < 0.001). The greatest recorded value was 6 V/m (GSM+UMTS 900 UL) in the NCCU staff area versus 3.70 V/m (UMTS 2100 UL) in NICU children's rooms; medical devices tested in the NICU did not emit detectable RF. Overall, measured RF-EMF levels in both units were described as very low and were attributed primarily to parents’ and staff members’ wireless device use rather than medical devices.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"Single-site study in one 34-bed tertiary pediatrics department\",\n    \"Frequency bands and metrics beyond those explicitly reported are not detailed in the abstract\",\n    \"No health outcomes assessed; exposure characterization only\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"RF-EMF\",\n    \"pediatrics\",\n    \"neonatal critical care unit\",\n    \"neonatal intensive care unit\",\n    \"preterm neonates\",\n    \"environmental measurements\",\n    \"dosimeters\",\n    \"GSM\",\n    \"UMTS\",\n    \"WiFi\",\n    \"DECT\",\n    \"Faraday chamber\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"school-wi-fi\",\n      \"weight\": 0.2,\n      \"reason\": \"WiFi networks mentioned as a potential source, though setting is a hospital neonatal unit rather than a school.\"\n    },\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.35,\n      \"reason\": \"Measurements include staff areas and suggest staff device use as a primary RF-EMF source.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://www.ncbi.nlm.nih.gov/pubmed/31740038",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=1640",
  "updated": "2026-02-10 12:16:56"
}