  "abstract": "Electric Field Exposure Assessments and a Novel Control Method for Buildings Installed Nearby High-Voltage Lines Shemshadi A, Maleki AK. Electric Field Exposure Assessments and a Novel Control Method for Buildings Installed Nearby High-Voltage Lines. Indian J Occup Environ Med. 2019 May-Aug;23(2):63-67. doi: 10.4103/ijoem.IJOEM_215_18. Abstract This essay presents a review of new methods for electric field value assessment in high-voltage areas. For buildings that are placed near high-voltage transmission line corridor, two main scenarios are modeled using finite element method. A new approach to reduce electric field value is also simulated and the results are discussed in detail. The results are compared to related standards values. In some cases the improvement rate exceeds 65%. https://www.ncbi.nlm.nih.gov/pubmed/31619877",
  "effect": "benefit",
  "evidence": "low",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "benefit",
    "evidenceLabel": "Low",
    "population": "—",
    "sampleSize": "—",
    "exposure": "ELF <1 MHz",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "The paper reviews methods for assessing electric field values in high-voltage areas and models two building scenarios near a high-voltage transmission line corridor using a finite element method. A simulated control approach to reduce electric field values is presented, with reported improvement rates exceeding 65% in some cases, and results are compared with related standards values.",
    "outcomes": [
      "Electric field value assessment near high-voltage areas/buildings",
      "Electric field reduction/control method performance",
      "Comparison to standards values"
    ],
    "limitations": [
      "Described as an essay/review with simulations",
      "no human health outcomes reported in the abstract",
      "Key exposure parameters (e.g.",
      "line voltage",
      "field strengths",
      "measurement details) are not provided in the abstract"
    ],
    "keywords": [
      "electric field",
      "exposure assessment",
      "high-voltage",
      "transmission lines",
      "finite element method",
      "building",
      "control method",
      "standards"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Published in an occupational/environmental medicine journal and concerns exposure assessment near high-voltage lines."
      }
    ],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": \"high-voltage transmission lines\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Electric field value assessment near high-voltage areas/buildings\",\n    \"Electric field reduction/control method performance\",\n    \"Comparison to standards values\"\n  ],\n  \"main_findings\": \"The paper reviews methods for assessing electric field values in high-voltage areas and models two building scenarios near a high-voltage transmission line corridor using a finite element method. A simulated control approach to reduce electric field values is presented, with reported improvement rates exceeding 65% in some cases, and results are compared with related standards values.\",\n  \"effect_direction\": \"benefit\",\n  \"limitations\": [\n    \"Described as an essay/review with simulations; no human health outcomes reported in the abstract\",\n    \"Key exposure parameters (e.g., line voltage, field strengths, measurement details) are not provided in the abstract\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"electric field\",\n    \"exposure assessment\",\n    \"high-voltage\",\n    \"transmission lines\",\n    \"finite element method\",\n    \"building\",\n    \"control method\",\n    \"standards\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.6,\n      \"reason\": \"Published in an occupational/environmental medicine journal and concerns exposure assessment near high-voltage lines.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://www.ncbi.nlm.nih.gov/pubmed/31619877",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=1685",
  "updated": "2026-02-10 12:17:28"
}