  "id": 1688,
  "url": "https://nnemf.org/research/1688-self-organizing-maps-classification-with-application-to-the",
  "title": "Self-organizing maps classification with application to the low-frequency magnetic field emitted by portable computers",
  "authors": [],
  "journal": "",
  "year": "2017",
  "doi": "10.1109/icatcct.2017.8389155",
  "pmid": null,
  "abstract": "Self-organizing maps classification with application to the low-frequency magnetic field emitted by portable computers",
  "effect": "mixed",
  "evidence": "low",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "mixed",
    "evidenceLabel": "Low",
    "population": "portable computer users (implied)",
    "sampleSize": "18",
    "exposure": "ELF <1 MHz",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "ELF magnetic field emissions were measured for 18 portable computers (9 laptops, 9 tablets) and classified using a Self-Organizing Map to identify typical emission levels. The authors state that some measured emission levels were far above valid safety standards' limits and describe laptops as having higher peaks than tablets, with one tablet described as completely safe for use.",
    "outcomes": [
      "Extremely low-frequency (ELF) magnetic field emission levels near portable computers",
      "Classification of emission levels using Self-Organizing Maps",
      "Comparison of emission levels across device types (laptop vs tablet) and measurement positions (top vs bottom)"
    ],
    "limitations": [
      "Specific safety standard(s) and numeric limit values are not provided in the abstract/excerpts",
      "No quantitative exposure values (e.g.",
      "microtesla) are reported in the provided text",
      "Measurement protocol details (distance",
      "instrumentation",
      "frequency range within ELF",
      "averaging) are not described in the provided text",
      "Health outcomes are not measured",
      "discussion of risk/negative effects is inferential"
    ],
    "keywords": [
      "self-organizing map",
      "SOM",
      "classification",
      "extremely low-frequency",
      "ELF",
      "magnetic field",
      "portable computers",
      "laptop",
      "tablet",
      "exposure measurement",
      "safety standards"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Study concerns ELF magnetic field exposure assessment near devices; occupational context not specified but exposure assessment may be relevant."
      }
    ],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": \"portable computers (laptops and tablets)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"portable computer users (implied)\",\n  \"sample_size\": 18,\n  \"outcomes\": [\n    \"Extremely low-frequency (ELF) magnetic field emission levels near portable computers\",\n    \"Classification of emission levels using Self-Organizing Maps\",\n    \"Comparison of emission levels across device types (laptop vs tablet) and measurement positions (top vs bottom)\"\n  ],\n  \"main_findings\": \"ELF magnetic field emissions were measured for 18 portable computers (9 laptops, 9 tablets) and classified using a Self-Organizing Map to identify typical emission levels. The authors state that some measured emission levels were far above valid safety standards' limits and describe laptops as having higher peaks than tablets, with one tablet described as completely safe for use.\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [\n    \"Specific safety standard(s) and numeric limit values are not provided in the abstract/excerpts\",\n    \"No quantitative exposure values (e.g., microtesla) are reported in the provided text\",\n    \"Measurement protocol details (distance, instrumentation, frequency range within ELF, averaging) are not described in the provided text\",\n    \"Health outcomes are not measured; discussion of risk/negative effects is inferential\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"self-organizing map\",\n    \"SOM\",\n    \"classification\",\n    \"extremely low-frequency\",\n    \"ELF\",\n    \"magnetic field\",\n    \"portable computers\",\n    \"laptop\",\n    \"tablet\",\n    \"exposure measurement\",\n    \"safety standards\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.2,\n      \"reason\": \"Study concerns ELF magnetic field exposure assessment near devices; occupational context not specified but exposure assessment may be relevant.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://ieeexplore.ieee.org/document/8389155",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=1688",