{
  "id": 1738,
  "url": "https://nnemf.org/research/1738-statistical-approach-for-human-electromagnetic-exposure-assessment-in",
  "title": "Statistical approach for human electromagnetic exposure assessment in future wireless ATTO-cell networks",
  "authors": [],
  "journal": "",
  "year": "2019",
  "doi": "10.1093/rpd/ncy120",
  "pmid": null,
  "abstract": "Statistical approach for human electromagnetic exposure assessment in future wireless ATTO-cell networks Shikhantsov S, Thielens A, Vermeeren G, Demeester P, Martens L, Torfs G, Joseph W. Statistical approach for human electromagnetic exposure assessment in future wireless ATTO-cell networks. Radiat Prot Dosimetry. 2019 May 1;183(3):326-331. doi: 10.1093/rpd/ncy120. Abstract In this article, we study human electromagnetic exposure to the radiation of an ultra dense network of nodes integrated in a floor denoted as ATTO-cell floor, or ATTO-floor. ATTO-cells are a prospective 5G wireless networking technology, in which humans are exposed by several interfering sources. To numerically estimate this exposure we propose a statistical approach based on a set of finite difference time domain simulations. It accounts for variations of antenna phases and makes use of a large number of exposure evaluations, based on a relatively low number of required simulations. The exposure was expressed in peak-spatial 10-g SAR average (psSAR10g). The results show an average exposure level of ~4.9 mW/kg and reaching 7.6 mW/kg in 5% of cases. The maximum psSAR10g value found in the studied numerical setup equals around 21.2 mW/kg. Influence of the simulated ATTO-floor size on the resulting exposure was examined. All obtained exposure levels are far below 4 W/kg ICNIRP basic restriction for general public in limbs (and 20 W/kg basic restriction for occupational exposure), which makes ATTO-floor a potential low-exposure 5 G candidate. : https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6543880/",
  "effect": "no_effect",
  "evidence": "low",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "no_effect",
    "evidenceLabel": "Low",
    "population": "—",
    "sampleSize": "—",
    "exposure": "RF 5G ATTO-cell (ultra-dense network integrated in floor) · 0.0049 W/kg",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "Using a statistical approach based on a set of finite difference time domain simulations accounting for antenna phase variations, estimated psSAR10g averaged ~4.9 mW/kg, reached 7.6 mW/kg in 5% of cases, and had a maximum around 21.2 mW/kg in the studied numerical setup. The authors report these exposure levels are far below ICNIRP basic restrictions (4 W/kg for general public in limbs; 20 W/kg for occupational exposure).",
    "outcomes": [
      "peak-spatial 10-g SAR average (psSAR10g)"
    ],
    "limitations": [
      "Numerical/simulation-based exposure estimation (finite difference time domain) rather than measurements in humans",
      "Results pertain to the studied numerical setup",
      "generalizability to other ATTO-floor configurations not stated"
    ],
    "keywords": [
      "ATTO-cell",
      "ATTO-floor",
      "5G",
      "ultra dense network",
      "exposure assessment",
      "FDTD",
      "SAR",
      "psSAR10g",
      "ICNIRP"
    ],
    "hubs": [
      {
        "slug": "who-icnirp",
        "weight": "0.7",
        "reason": "Abstract explicitly compares estimated SAR to ICNIRP basic restrictions."
      },
      {
        "slug": "5g-policy",
        "weight": "0.7",
        "reason": "Study concerns a prospective 5G wireless networking technology (ATTO-cells) and evaluates exposure relative to limits."
      }
    ],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"5G ATTO-cell (ultra-dense network integrated in floor)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": 0.0049,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"peak-spatial 10-g SAR average (psSAR10g)\"\n  ],\n  \"main_findings\": \"Using a statistical approach based on a set of finite difference time domain simulations accounting for antenna phase variations, estimated psSAR10g averaged ~4.9 mW/kg, reached 7.6 mW/kg in 5% of cases, and had a maximum around 21.2 mW/kg in the studied numerical setup. The authors report these exposure levels are far below ICNIRP basic restrictions (4 W/kg for general public in limbs; 20 W/kg for occupational exposure).\",\n  \"effect_direction\": \"no_effect\",\n  \"limitations\": [\n    \"Numerical/simulation-based exposure estimation (finite difference time domain) rather than measurements in humans\",\n    \"Results pertain to the studied numerical setup; generalizability to other ATTO-floor configurations not stated\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"ATTO-cell\",\n    \"ATTO-floor\",\n    \"5G\",\n    \"ultra dense network\",\n    \"exposure assessment\",\n    \"FDTD\",\n    \"SAR\",\n    \"psSAR10g\",\n    \"ICNIRP\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"who-icnirp\",\n      \"weight\": 0.6,\n      \"reason\": \"Abstract explicitly compares estimated SAR to ICNIRP basic restrictions.\"\n    },\n    {\n      \"slug\": \"5g-policy\",\n      \"weight\": 0.45,\n      \"reason\": \"Study concerns a prospective 5G wireless networking technology (ATTO-cells) and evaluates exposure relative to limits.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6543880/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=1738",
  "updated": "2026-02-10 12:18:00"
}