  "id": 2046,
  "url": "https://nnemf.org/research/2046-the-human-skin-as-a-sub-thz-receiver",
  "title": "The human skin as a sub-THz receiver - Does 5G pose a danger to it or not?",
  "authors": [],
  "journal": "",
  "year": "2018",
  "doi": "10.1016/j.envres.2018.01.032",
  "pmid": null,
  "abstract": "The human skin as a sub-THz receiver - Does 5G pose a danger to it or not? Betzalel N, Ben",
  "effect": "unclear",
  "evidence": "very_low",
  "extraction": {
    "studyType": "review",
    "studyTypeLabel": "Review",
    "effectDirection": "unclear",
    "evidenceLabel": "Very low",
    "population": "Human skin (modeled; prior experimental reflectance observations referenced)",
    "sampleSize": "—",
    "exposure": "RF >3000 MHz",
    "confidencePct": "66",
    "peerReviewed": "yes",
    "mainFindings": "The paper summarizes prior physical/experimental observations and introduces/uses a multi-layer skin electromagnetic model including a helical sweat duct segment; the presence of the sweat duct is reported to lead to high SAR in the skin in the extremely high frequency band. The authors state that implications for public health are unclear and raise a warning flag regarding unrestricted use of sub-THz/5G technologies before possible consequences are explored.",
    "outcomes": [
      "Skin reflectance in sub-THz region (dependence on perspiration/sweat duct conductivity)",
      "Circular dichroism in skin reflectance (interpreted as axial mode of helical antenna)",
      "Correlation of ECG parameters with sub-THz skin reflection coefficient",
      "Specific absorption rate (SAR) in skin in extremely high frequency band (simulation/modeling)",
      "Potential non-thermal biological effects (discussed as a concern)"
    ],
    "limitations": [
      "Full ramifications of the reported findings for human health are stated to be unclear",
      "Health consequences are discussed as concerns rather than demonstrated outcomes in this abstract",
      "Key quantitative exposure parameters (exact frequencies",
      "SAR values) are not provided in the abstract"
    ],
    "keywords": [
      "5G",
      "sub-THz",
      "mmWave",
      "extremely high frequency",
      "human skin",
      "sweat duct",
      "helical antenna",
      "reflectance",
      "circular dichroism",
      "SAR",
      "non-thermal effects",
      "FCC 24 GHz"
    ],
    "hubs": [
      {
        "slug": "5g-policy",
        "weight": "0.7",
        "reason": "Discusses FCC rules above 24 GHz for 5G and raises concerns about unrestricted sub-THz/5G deployment."
      }
    ],
    "raw": "{\n  \"study_type\": \"review\",\n  \"exposure\": {\n    \"band\": \"sub-THz / extremely high frequency (mmWave)\",\n    \"source\": \"5G wireless communications (base stations/devices)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"Human skin (modeled; prior experimental reflectance observations referenced)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Skin reflectance in sub-THz region (dependence on perspiration/sweat duct conductivity)\",\n    \"Circular dichroism in skin reflectance (interpreted as axial mode of helical antenna)\",\n    \"Correlation of ECG parameters with sub-THz skin reflection coefficient\",\n    \"Specific absorption rate (SAR) in skin in extremely high frequency band (simulation/modeling)\",\n    \"Potential non-thermal biological effects (discussed as a concern)\"\n  ],\n  \"main_findings\": \"The paper summarizes prior physical/experimental observations and introduces/uses a multi-layer skin electromagnetic model including a helical sweat duct segment; the presence of the sweat duct is reported to lead to high SAR in the skin in the extremely high frequency band. The authors state that implications for public health are unclear and raise a warning flag regarding unrestricted use of sub-THz/5G technologies before possible consequences are explored.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"Full ramifications of the reported findings for human health are stated to be unclear\",\n    \"Health consequences are discussed as concerns rather than demonstrated outcomes in this abstract\",\n    \"Key quantitative exposure parameters (exact frequencies, SAR values) are not provided in the abstract\"\n  ],\n  \"evidence_strength\": \"very_low\",\n  \"confidence\": 0.66,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"5G\",\n    \"sub-THz\",\n    \"mmWave\",\n    \"extremely high frequency\",\n    \"human skin\",\n    \"sweat duct\",\n    \"helical antenna\",\n    \"reflectance\",\n    \"circular dichroism\",\n    \"SAR\",\n    \"non-thermal effects\",\n    \"FCC 24 GHz\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"5g-policy\",\n      \"weight\": 0.86,\n      \"reason\": \"Discusses FCC rules above 24 GHz for 5G and raises concerns about unrestricted sub-THz/5G deployment.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://ieeexplore.ieee.org/document/8016593/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=2046",
  "updated": "2026-02-10 12:29:39"
}