Effect of RF EMF from mobile phones on nickel release from orthodontic brackets: An in vitro study

PAPERmanual2018In vitro studyEffect: harmEvidence: Low

Abstract

Effect of RF EMF from mobile phones on nickel release from orthodontic brackets: An in vitro study Seyed Mohammad S, Mortazavi J, Paknahad M, Khaleghi I, Eghlidospour M. Effect of radiofrequency electromagnetic fields (RF-EMFS) from mobile phones on nickel release from orthodontic brackets: An in vitro study. International Orthodontics, Available online 12 July 2018. Summary Background The worldwide dramatic increase in the use of cell phones has generated great concerns about their potential adverse health effects. Objective The aim of the present study was to evaluate the effects of radiofrequency electromagnetic fields (RF- EMFs) emitted from mobile phones on the level of nickel release from orthodontic brackets. Methods Twenty stainless steel brackets were divided randomly into experimental and control groups (n = 10). Brackets were immersed in artificial saliva at 37 °C for 6 months. Experimental group were exposed to GSM 900 MHz RF-EMFs emitted from a mobile phone stimulator for 4 hours. The specific absorption rate (SAR) was 2.287 W/kg. The concentration of nickel in the artificial saliva in both groups was evaluated by using the cold-vapour atomic absorption spectrometry. The Mann-Whitney test was used to assess significant differences in nickel release between the exposed and non-exposed groups. Results The mean nickel levels in the exposed and non-exposed groups were 11.95 and 2.89 μg/l, respectively. This difference between the concentrations of nickel in the artificial saliva of these groups was statistically significant (P = 0.001). Conclusion Exposure to RF-EMFs emitted from mobile phones can lead to human exposure to higher levels of nickel in saliva in patients with orthodontic appliances. As nickel exposure can lead to allergic reaction in humans and considering this point that about 10-20% of the population can be hypersensitive to nickel, further studies are needed to evaluate the effects of radiofrequency electromagnetic fields (RF-EMFs) emitted from common devices such as mobile phones or Wi-Fi routers on the level of nickel release from orthodontic brackets. sciencedirect.com

AI evidence extraction

At a glance
Study type
In vitro study
Effect direction
harm
Population
—
Sample size
20
Exposure
RF mobile phone · 900 MHz · 2.287 W/kg · 4 hours
Evidence strength
Low
Confidence: 78% · Peer-reviewed: unknown

Main findings

Twenty stainless steel orthodontic brackets were immersed in artificial saliva for 6 months; the exposed group (GSM 900 MHz, SAR 2.287 W/kg, 4 hours) had higher mean nickel levels in saliva (11.95 μg/L) than the non-exposed group (2.89 μg/L), with a statistically significant difference (P = 0.001).

Outcomes measured

  • Nickel release from orthodontic brackets (nickel concentration in artificial saliva
  • μg/L)

Limitations

  • In vitro study using artificial saliva and brackets
  • findings may not directly translate to in vivo patient exposure.
  • Small sample size (n=20
  • 10 per group).
  • Exposure described as 4 hours using a mobile phone stimulator
  • other real-world usage patterns/devices not assessed.
View raw extracted JSON
{
  "study_type": "in_vitro",
  "exposure": {
    "band": "RF",
    "source": "mobile phone",
    "frequency_mhz": 900,
    "sar_wkg": 2.287,
    "duration": "4 hours"
  },
  "population": null,
  "sample_size": 20,
  "outcomes": [
    "Nickel release from orthodontic brackets (nickel concentration in artificial saliva, μg/L)"
  ],
  "main_findings": "Twenty stainless steel orthodontic brackets were immersed in artificial saliva for 6 months; the exposed group (GSM 900 MHz, SAR 2.287 W/kg, 4 hours) had higher mean nickel levels in saliva (11.95 μg/L) than the non-exposed group (2.89 μg/L), with a statistically significant difference (P = 0.001).",
  "effect_direction": "harm",
  "limitations": [
    "In vitro study using artificial saliva and brackets; findings may not directly translate to in vivo patient exposure.",
    "Small sample size (n=20; 10 per group).",
    "Exposure described as 4 hours using a mobile phone stimulator; other real-world usage patterns/devices not assessed."
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "unknown",
  "keywords": [
    "RF-EMF",
    "mobile phones",
    "GSM 900 MHz",
    "SAR",
    "nickel release",
    "orthodontic brackets",
    "artificial saliva",
    "in vitro"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 2065

Effect of RF EMF from mobile phones on nickel release from orthodontic brackets: An in vitro study · Non-native EMF