Share

Characteristics of perceived electromagnetic hypersensitivity in the general population

PAPERmanual2018cross sectionalEffect: unclearEvidence: Low

Abstract

Characteristics of perceived electromagnetic hypersensitivity in the general population Gruber MJ, Palmquist E, Nordin S. Characteristics of perceived electromagnetic hypersensitivity in the general population. Scand J Psychol. 2018 May 9. doi: 10.1111/sjop.12449. Abstract Health problems evoked in the presence of electrical equipment is a concern, calling for better understanding for characteristics of electromagnetic hypersensitivity (EHS) in the general population. The present study investigated demographics, lifestyle factors, frequency and duration, coping strategies, proportion meeting clinical criteria for intolerance attributed to electromagnetic fields (EMF) and comorbidity. Using data from a large-scale population-based questionnaire study, we investigated persons with self-reported (n = 91) EHS in comparison to referents (n = 3,250). Middle age, female sex and poor perceived health was found to be associated with EHS. More than 50% in the EHS group reported having EMF-related symptoms more often than once a week, and the mean number of years experiencing EHS was 10.5. More than half of the EHS group reported that their symptoms started after a high-dose or long-term EMF exposure, that they actively tried to avoid EMF sources and that they mostly could affect the EMF environment. A minority of the EHS group had sought medical attention, been diagnosed by a physician or received treatment. Exhaustion syndrome, anxiety disorder, back/joint/muscle disorder, depression, functional somatic syndrome and migraine were comorbid with EHS. The results provide ground for future study of these characteristic features being risk factors for development of EHS and or consequences of EHS. ncbi.nlm.nih.gov

AI evidence extraction

At a glance
Study type
cross sectional
Effect direction
unclear
Population
General population (population-based questionnaire respondents); self-reported EHS cases vs referents
Sample size
3341
Exposure
electrical equipment / EMF sources (self-reported) · Mean 10.5 years experiencing EHS; >50% reported symptoms more often than once a week
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

In a population-based questionnaire, middle age, female sex, and poor perceived health were associated with self-reported EHS (n=91) compared with referents (n=3,250). Over half of the EHS group reported EMF-related symptoms more often than weekly and reported symptom onset after high-dose or long-term EMF exposure; avoidance of EMF sources was common, while medical consultation/diagnosis/treatment was reported by a minority. Several conditions (including exhaustion syndrome, anxiety disorder, depression, functional somatic syndrome, and migraine) were reported as comorbid with EHS.

Outcomes measured

  • Self-reported electromagnetic hypersensitivity (EHS) characteristics (frequency
  • duration
  • coping/avoidance)
  • Demographics and lifestyle factors associated with self-reported EHS
  • Proportion meeting clinical criteria for intolerance attributed to EMF
  • Healthcare seeking/diagnosis/treatment related to EHS
  • Comorbidities (exhaustion syndrome
  • anxiety disorder
  • back/joint/muscle disorder
  • depression
  • functional somatic syndrome
  • migraine)

Limitations

  • Exposure characteristics (frequency
  • intensity
  • SAR) not specified
  • relies on self-reported EHS and self-reported exposure history
  • Cross-sectional questionnaire design limits causal inference

Suggested hubs

  • who-icnirp (0.7)
    Addresses EHS/intolerance attributed to EMF in the general population, relevant to broader EMF health guidance discussions.
View raw extracted JSON
{
  "study_type": "cross_sectional",
  "exposure": {
    "band": null,
    "source": "electrical equipment / EMF sources (self-reported)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": "Mean 10.5 years experiencing EHS; >50% reported symptoms more often than once a week"
  },
  "population": "General population (population-based questionnaire respondents); self-reported EHS cases vs referents",
  "sample_size": 3341,
  "outcomes": [
    "Self-reported electromagnetic hypersensitivity (EHS) characteristics (frequency, duration, coping/avoidance)",
    "Demographics and lifestyle factors associated with self-reported EHS",
    "Proportion meeting clinical criteria for intolerance attributed to EMF",
    "Healthcare seeking/diagnosis/treatment related to EHS",
    "Comorbidities (exhaustion syndrome, anxiety disorder, back/joint/muscle disorder, depression, functional somatic syndrome, migraine)"
  ],
  "main_findings": "In a population-based questionnaire, middle age, female sex, and poor perceived health were associated with self-reported EHS (n=91) compared with referents (n=3,250). Over half of the EHS group reported EMF-related symptoms more often than weekly and reported symptom onset after high-dose or long-term EMF exposure; avoidance of EMF sources was common, while medical consultation/diagnosis/treatment was reported by a minority. Several conditions (including exhaustion syndrome, anxiety disorder, depression, functional somatic syndrome, and migraine) were reported as comorbid with EHS.",
  "effect_direction": "unclear",
  "limitations": [
    "Exposure characteristics (frequency, intensity, SAR) not specified; relies on self-reported EHS and self-reported exposure history",
    "Cross-sectional questionnaire design limits causal inference"
  ],
  "evidence_strength": "low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "electromagnetic hypersensitivity",
    "EHS",
    "self-reported symptoms",
    "questionnaire",
    "general population",
    "avoidance",
    "comorbidity",
    "intolerance attributed to EMF"
  ],
  "suggested_hubs": [
    {
      "slug": "who-icnirp",
      "weight": 0.2,
      "reason": "Addresses EHS/intolerance attributed to EMF in the general population, relevant to broader EMF health guidance discussions."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 2096

Characteristics of perceived electromagnetic hypersensitivity in the general population · Non-native EMF