  "id": 2132,
  "url": "https://nnemf.org/research/2132-rf-exposure-assessment-of-baby-surveillance-devices-in",
  "title": "RF exposure assessment of baby surveillance devices in the frequency range 400 MHz-2.45",
  "authors": [],
  "journal": "",
  "year": "2018",
  "doi": "10.1002/bem.22113",
  "pmid": null,
  "abstract": "RF exposure assessment of baby surveillance devices in the frequency range 400 MHz-2.45 GHz Vermeeren G, Joseph W, Martens L. Radiofrequency exposure assessment of baby surveillance devices in the frequency range 400 MHz-2.45 GHz. Bioelectromagnetics. 2018 Apr;39(3):244-248. doi: 10.1002/bem.22113. No abstract Excerpts We investigated the exposure, in terms of both the peak spatial‐averaged specific absorption rate (SAR) in 10 g of tissue and the time-averaged root-mean-squared (RMS) electric (E) field, induced by baby monitors operating in a frequency range between 400 MHz and 2.45 GHz. We selected nine commercially available baby monitors ... Considering all investigated devices, the peak spatial SAR in 10 g ranged from 0.09 to 0.37 W/kg, which is 22.3- 5.4 times below the ICNIRP basic restriction. In summary, we measured the induced time-averaged root-mean-square electric field strength and the peak spatial-averaged specific absorption rate from the baby unit of nine commercially available devices and compared both with the ICNIRP guidelines. The communication technologies implemented in the baby monitors were: PMR446, continuous transmission at 864 MHz, DECT, and communication in the ISM band at 2450 MHz. The electric field was measured at a distance of 50 cm from the baby unit of the baby monitor. We measured the SAR in a flat phantom filled with head tissue simulating liquid and the baby unit touching the flat phantom. The maximum time-averaged root-mean-square electric field value closest to the ICNIRP reference level over all investigated devices was 1.51 V/m (for modern‐electronics DBS 3), which is 19.4 times below the ICNIRP reference level at 466 MHz. The peak spatial‐averaged SAR in 10 g of tissue was 0.37 W/kg in head simulating tissue (for Alecto-DBX-82), which is 5.4 times below the basic restriction of 2 W/kg as specified by ICNIRP. https://www.ncbi.nlm.nih.gov/pubmed/29492985 Note: The ICNIRP guidelines were designed to protect users only from short-term thermal effects.",
  "effect": "no_effect",
  "evidence": "low",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "no_effect",
    "evidenceLabel": "Low",
    "population": "—",
    "sampleSize": "9",
    "exposure": "RF baby monitor · 0.37 W/kg",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Nine commercially available baby monitors (400 MHz–2.45 GHz; PMR446, 864 MHz continuous transmission, DECT, and 2450 MHz ISM) were assessed. Peak spatial-averaged SAR in 10 g ranged from 0.09 to 0.37 W/kg, reported as 22.3–5.4 times below the ICNIRP basic restriction; the maximum measured time-averaged RMS E-field at 50 cm was 1.51 V/m, reported as 19.4 times below the ICNIRP reference level at 466 MHz.",
    "outcomes": [
      "Peak spatial-averaged SAR in 10 g tissue (W/kg)",
      "Time-averaged RMS electric field strength (V/m)",
      "Comparison with ICNIRP basic restrictions/reference levels"
    ],
    "limitations": [
      "No abstract provided",
      "information is from excerpts only",
      "E-field measurements were taken at a single stated distance (50 cm) from the baby unit",
      "SAR measurements used a flat phantom with head-tissue simulating liquid and the baby unit touching the phantom",
      "Only nine commercially available devices were selected",
      "selection criteria not described in provided text"
    ],
    "keywords": [
      "baby monitor",
      "baby surveillance devices",
      "radiofrequency",
      "RF exposure",
      "SAR",
      "10 g SAR",
      "RMS electric field",
      "PMR446",
      "DECT",
      "ISM 2450 MHz",
      "ICNIRP"
    ],
    "hubs": [
      {
        "slug": "who-icnirp",
        "weight": "0.7",
        "reason": "Study explicitly compares measured SAR and E-field values with ICNIRP basic restrictions/reference levels."
      }
    ],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"baby monitor\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": 0.37,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": 9,\n  \"outcomes\": [\n    \"Peak spatial-averaged SAR in 10 g tissue (W/kg)\",\n    \"Time-averaged RMS electric field strength (V/m)\",\n    \"Comparison with ICNIRP basic restrictions/reference levels\"\n  ],\n  \"main_findings\": \"Nine commercially available baby monitors (400 MHz–2.45 GHz; PMR446, 864 MHz continuous transmission, DECT, and 2450 MHz ISM) were assessed. Peak spatial-averaged SAR in 10 g ranged from 0.09 to 0.37 W/kg, reported as 22.3–5.4 times below the ICNIRP basic restriction; the maximum measured time-averaged RMS E-field at 50 cm was 1.51 V/m, reported as 19.4 times below the ICNIRP reference level at 466 MHz.\",\n  \"effect_direction\": \"no_effect\",\n  \"limitations\": [\n    \"No abstract provided; information is from excerpts only\",\n    \"E-field measurements were taken at a single stated distance (50 cm) from the baby unit\",\n    \"SAR measurements used a flat phantom with head-tissue simulating liquid and the baby unit touching the phantom\",\n    \"Only nine commercially available devices were selected; selection criteria not described in provided text\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"baby monitor\",\n    \"baby surveillance devices\",\n    \"radiofrequency\",\n    \"RF exposure\",\n    \"SAR\",\n    \"10 g SAR\",\n    \"RMS electric field\",\n    \"PMR446\",\n    \"DECT\",\n    \"ISM 2450 MHz\",\n    \"ICNIRP\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"who-icnirp\",\n      \"weight\": 0.78,\n      \"reason\": \"Study explicitly compares measured SAR and E-field values with ICNIRP basic restrictions/reference levels.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://www.ncbi.nlm.nih.gov/pubmed/29492985",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=2132",
  "updated": "2026-02-10 12:30:30"
}