Share

Assessment of exposure to RF EMF from smart meters in GB; part II) numerical assessment of SAR within human body

PAPERmanual2017exposure assessmentEffect: no_effectEvidence: Low

Abstract

Assessment of exposure to RF EMF from smart meters in GB; part II) numerical assessment of SAR within human body Qureshi MRA, Alfadhl Y, Chen X, Peyman A, Maslanyj M, Mann S. Assessment of exposure to radio frequency electromagnetic fields from smart utility meters in GB; part II) numerical assessment of induced SAR within the human body. Bioelectromagnetics. 2017 Nov 16. Abstract Human body exposure to radiofrequency electromagnetic waves emitted from smart meters was assessed using various exposure configurations. Specific energy absorption rate distributions were determined using three anatomically realistic human models. Each model was assigned with age- and frequency-dependent dielectric properties representing a collection of age groups. Generalized exposure conditions involving standing and sleeping postures were assessed for a home area network operating at 868 and 2,450 MHz. The smart meter antenna was fed with 1 W power input which is an overestimation of what real devices typically emit (15 mW max limit). The highest observed whole body specific energy absorption rate value was 1.87 mW kg-1, within the child model at a distance of 15 cm from a 2,450 MHz device. The higher values were attributed to differences in dimension and dielectric properties within the model. Specific absorption rate (SAR) values were also estimated based on power density levels derived from electric field strength measurements made at various distances from smart meter devices. All the calculated SAR values were found to be very small in comparison to International Commission on Non-Ionizing Radiation Protection limits for public exposure. ncbi.nlm.nih.gov Also see: Health Experts Caution About Smart Meters

AI evidence extraction

At a glance
Study type
exposure assessment
Effect direction
no_effect
Population
—
Sample size
3
Exposure
RF 100–1000 MHz
Evidence strength
Low
Confidence: 78% · Peer-reviewed: yes

Main findings

Numerical simulations using three anatomically realistic human models assessed SAR for home area network smart meter exposures at 868 and 2,450 MHz under standing and sleeping configurations. With a 1 W antenna feed (noted as an overestimate vs a 15 mW max limit), the highest whole-body SAR reported was 1.87 mW/kg in the child model at 15 cm from a 2,450 MHz device; calculated SAR values were described as very small compared with ICNIRP public exposure limits.

Outcomes measured

  • Specific absorption rate (SAR) distributions
  • Whole-body SAR
  • Comparison to ICNIRP public exposure limits

Limitations

  • Antenna feed power set to 1 W
  • stated to be an overestimation relative to typical smart meter emissions (15 mW max limit)
  • Numerical modeling study
  • results depend on model assumptions (anatomical models
  • dielectric properties
  • exposure configurations)
  • Only three human models were used

Suggested hubs

  • smart-meters (0.7)
    Study assesses RF EMF exposure and SAR from smart utility meters.
View raw extracted JSON
{
  "study_type": "exposure_assessment",
  "exposure": {
    "band": "RF",
    "source": "smart meter",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": 3,
  "outcomes": [
    "Specific absorption rate (SAR) distributions",
    "Whole-body SAR",
    "Comparison to ICNIRP public exposure limits"
  ],
  "main_findings": "Numerical simulations using three anatomically realistic human models assessed SAR for home area network smart meter exposures at 868 and 2,450 MHz under standing and sleeping configurations. With a 1 W antenna feed (noted as an overestimate vs a 15 mW max limit), the highest whole-body SAR reported was 1.87 mW/kg in the child model at 15 cm from a 2,450 MHz device; calculated SAR values were described as very small compared with ICNIRP public exposure limits.",
  "effect_direction": "no_effect",
  "limitations": [
    "Antenna feed power set to 1 W, stated to be an overestimation relative to typical smart meter emissions (15 mW max limit)",
    "Numerical modeling study; results depend on model assumptions (anatomical models, dielectric properties, exposure configurations)",
    "Only three human models were used"
  ],
  "evidence_strength": "low",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "smart meters",
    "radiofrequency electromagnetic fields",
    "RF EMF",
    "SAR",
    "whole-body SAR",
    "home area network",
    "868 MHz",
    "2450 MHz",
    "ICNIRP",
    "numerical assessment",
    "human models"
  ],
  "suggested_hubs": [
    {
      "slug": "smart-meters",
      "weight": 0.95,
      "reason": "Study assesses RF EMF exposure and SAR from smart utility meters."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 2215

Assessment of exposure to RF EMF from smart meters in GB; part II) numerical assessment of SAR within human body · Non-native EMF