  "title": "Spatial and temporal assessment of radiofrequency electromagnetic fields emitted by smart meters and smart meter banks in urban environments.",
  "authors": [
    "Sam Aerts",
    "Matthias Van den Bossche",
    "Ximena Vergara",
    "Simon Odie",
    "Leen Verloock",
    "Luc Martens",
    "Wout Joseph"
  ],
  "journal": "Environmental research",
  "year": "2020",
  "doi": "10.1016/j.envres.2020.109196",
  "pmid": "32032814",
  "abstract": "This paper describes radiofrequency (RF) electromagnetic field (EMF) measurements in the vicinity of single and banks of advanced metering infrastructure (AMI) smart meters. The measurements were performed in a meter testing and distribution facility as well as in-situ at five urban locations. The measurements consisted of gauging the RF environment at the place of assessment, evaluating the worst-case electric-field levels at various positions around the assessed AMI meter configuration (spatial assessment), which ranged from a single meter to a bank of 81 m, and calculating the duty cycle of the system, i.e. the fraction of time that the AMI meters were actually transmitting (12-h temporal assessment). Both in-situ and in the meter facility, the maximum field levels at 0.3 m from the meter configurations were 10-13 V/m for a single meter and 18-38 V/m for meter banks with 20-81 m. Furthermore, 6-min average duty cycles of 0.01% (1 m) up to 13% (81-m bank) were observed. Next, two general statistical models (one for a single meter and one for a meter bank) were constructed to predict the electric-field strength as a function of distance to any configuration of the assessed AMI meters. For all scenarios, the measured exposure levels (at a minimum distance of 0.3 m) were well below the maximum permissible exposure limits issued by the International Commission on Non-Ionizing Radiation Protection (ICNIRP), the U.S. Federal Communications Commission (FCC), and the Institute of Electrical and Electronics Engineers (IEEE). Indeed, the worst-case time-average exposure level at a distance of 0.3 m from an AMI installation was 5.39% of the FCC/IEEE and 9.43% of the ICNIRP reference levels.",
  "effect": "no_effect",
  "evidence": "moderate",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "no_effect",
    "evidenceLabel": "Moderate",
    "population": "—",
    "sampleSize": "—",
    "exposure": "RF smart meter · 12-h temporal assessment; 6-min average duty cycles reported",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "RF-EMF measurements around single AMI smart meters and banks (up to 81 meters) found maximum field levels at 0.3 m of 10–13 V/m for a single meter and 18–38 V/m for banks of 20–81 meters. Observed 6-min average duty cycles ranged from 0.01% (single meter) up to 13% (81-meter bank). For all scenarios, measured exposure levels at a minimum distance of 0.3 m were reported to be well below ICNIRP, FCC, and IEEE limits; the worst-case time-average exposure at 0.3 m was 5.39% of FCC/IEEE and 9.43% of ICNIRP reference levels.",
    "outcomes": [
      "Electric-field strength (V/m) around AMI smart meters and meter banks",
      "Duty cycle / fraction of time transmitting (temporal assessment)",
      "Comparison to ICNIRP",
      "FCC",
      "and IEEE maximum permissible exposure/reference levels",
      "Statistical models predicting electric-field strength as a function of distance"
    ],
    "limitations": [],
    "keywords": [
      "radiofrequency",
      "RF-EMF",
      "smart meters",
      "advanced metering infrastructure",
      "AMI",
      "meter banks",
      "urban environments",
      "electric-field strength",
      "duty cycle",
      "ICNIRP",
      "FCC",
      "IEEE",
      "exposure assessment"
    ],
    "hubs": [
      {
        "slug": "smart-meters",
        "weight": "0.7",
        "reason": "Direct RF-EMF measurements of AMI smart meters and smart meter banks, including duty cycle and comparison to exposure limits."
      },
      {
        "slug": "who-icnirp",
        "weight": "0.7",
        "reason": "Explicit comparison of measured levels to ICNIRP reference levels."
      }
    ],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"smart meter\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"12-h temporal assessment; 6-min average duty cycles reported\"\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Electric-field strength (V/m) around AMI smart meters and meter banks\",\n    \"Duty cycle / fraction of time transmitting (temporal assessment)\",\n    \"Comparison to ICNIRP, FCC, and IEEE maximum permissible exposure/reference levels\",\n    \"Statistical models predicting electric-field strength as a function of distance\"\n  ],\n  \"main_findings\": \"RF-EMF measurements around single AMI smart meters and banks (up to 81 meters) found maximum field levels at 0.3 m of 10–13 V/m for a single meter and 18–38 V/m for banks of 20–81 meters. Observed 6-min average duty cycles ranged from 0.01% (single meter) up to 13% (81-meter bank). For all scenarios, measured exposure levels at a minimum distance of 0.3 m were reported to be well below ICNIRP, FCC, and IEEE limits; the worst-case time-average exposure at 0.3 m was 5.39% of FCC/IEEE and 9.43% of ICNIRP reference levels.\",\n  \"effect_direction\": \"no_effect\",\n  \"limitations\": [],\n  \"evidence_strength\": \"moderate\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"radiofrequency\",\n    \"RF-EMF\",\n    \"smart meters\",\n    \"advanced metering infrastructure\",\n    \"AMI\",\n    \"meter banks\",\n    \"urban environments\",\n    \"electric-field strength\",\n    \"duty cycle\",\n    \"ICNIRP\",\n    \"FCC\",\n    \"IEEE\",\n    \"exposure assessment\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"smart-meters\",\n      \"weight\": 0.95,\n      \"reason\": \"Direct RF-EMF measurements of AMI smart meters and smart meter banks, including duty cycle and comparison to exposure limits.\"\n    },\n    {\n      \"slug\": \"who-icnirp\",\n      \"weight\": 0.6,\n      \"reason\": \"Explicit comparison of measured levels to ICNIRP reference levels.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/32032814/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=2417",
  "updated": "2026-02-09 13:19:57"
}