Share

The Effect of High-Voltage Power Lines on Magnetic Orientation of Domestic Dogs

Iakovenko NS, Benediktová K, Adámková J, Hart V, Brinkeová H, Ježek M, Kučera T, Hanzal V, Nováková P, Burda H

PAPERmanualAnimals (Basel)2025Animal studyEffect: mixedEvidence: Low

Abstract

Category: Behavioral Neuroscience Tags: domestic dogs, magnetic orientation, high-voltage power lines, electromagnetic fields, geomagnetic field, animal behavior, health risk DOI: 10.3390/ani15243534 URL: mdpi.com Overview Domestic dogs are known to sense the geomagnetic field (GMF) and naturally align their bodies along its axis, with altered alignment during geomagnetic disturbances. This study explored whether anthropogenic magnetic fields (MF) from high-voltage power lines (PL) influence this magnetic alignment behavior in dogs. Methods - 36 dogs were observed, with behavior recorded under both north-south (NS) and east-west (EW) oriented power lines. - Control conditions excluded anthropogenic magnetic fields. - Each dog’s mean alignment angle was calculated from over 50 measurements in each scenario. - Grand Means (GMs) were derived and compared. Findings - Under control (geomagnetically calm) conditions, dogs showed a bimodal alignment (GM = 23°/203°). - Geomagnetic storms caused significant shifts in alignment and increased angular dispersion. - Under NS-oriented power lines, the bimodal pattern persisted (GM = 5°/185°). - Under EW-oriented lines, alignment became trimodal (nodes = 3, p = 0.042; GM = 103°/283°), with significant statistical differences compared to control (LME for linearized angles: p < 0.001). Conclusion - Dogs maintain directional alignment even when exposed to magnetic fields from power lines. - The orientation pattern corresponds to both the MF and direction of the power lines. - This demonstrates a possible complex impact involving both magnetic and non-magnetic cues in dogs' orientation behavior. - Importantly, this link between electromagnetic fields from power lines and behavioral alteration in dogs points to a significant interaction with bioelectric processes, supporting concerns about EMF exposure and its biological effects.

AI evidence extraction

At a glance
Study type
Animal study
Effect direction
mixed
Population
Domestic dogs
Sample size
36
Exposure
ELF
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

In control (geomagnetically calm) conditions, dogs showed a bimodal alignment (grand mean 23°/203°). Under north-south oriented power lines, the bimodal pattern persisted (grand mean 5°/185°), while under east-west oriented power lines alignment became trimodal (nodes=3, p=0.042) and differed statistically from control (LME p<0.001).

Outcomes measured

  • magnetic orientation/alignment behavior (body alignment angles
  • bimodal vs trimodal patterns)
  • changes in angular dispersion during geomagnetic storms

Limitations

  • Frequency and intensity/field strength of the power-line magnetic fields were not reported in the provided abstract.
  • Exposure duration and distance from power lines were not described in the provided abstract.
  • Control condition definition is brief
  • details on how anthropogenic magnetic fields were excluded are not provided in the provided abstract.
  • Potential confounding by non-magnetic cues is acknowledged but not resolved in the provided abstract.

Suggested hubs

  • power-lines (0.7)
    Study explicitly examines effects of high-voltage power lines (anthropogenic magnetic fields) on behavior.
View raw extracted JSON
{
  "study_type": "animal",
  "exposure": {
    "band": null,
    "source": "high-voltage power lines",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": "Domestic dogs",
  "sample_size": 36,
  "outcomes": [
    "magnetic orientation/alignment behavior (body alignment angles; bimodal vs trimodal patterns)",
    "changes in angular dispersion during geomagnetic storms"
  ],
  "main_findings": "In control (geomagnetically calm) conditions, dogs showed a bimodal alignment (grand mean 23°/203°). Under north-south oriented power lines, the bimodal pattern persisted (grand mean 5°/185°), while under east-west oriented power lines alignment became trimodal (nodes=3, p=0.042) and differed statistically from control (LME p<0.001).",
  "effect_direction": "mixed",
  "limitations": [
    "Frequency and intensity/field strength of the power-line magnetic fields were not reported in the provided abstract.",
    "Exposure duration and distance from power lines were not described in the provided abstract.",
    "Control condition definition is brief; details on how anthropogenic magnetic fields were excluded are not provided in the provided abstract.",
    "Potential confounding by non-magnetic cues is acknowledged but not resolved in the provided abstract."
  ],
  "evidence_strength": "low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "domestic dogs",
    "magnetic orientation",
    "high-voltage power lines",
    "electromagnetic fields",
    "geomagnetic field",
    "animal behavior",
    "geomagnetic storms"
  ],
  "suggested_hubs": [
    {
      "slug": "power-lines-elf",
      "weight": 0.9,
      "reason": "Study explicitly examines effects of high-voltage power lines (anthropogenic magnetic fields) on behavior."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 2471

The Effect of High-Voltage Power Lines on Magnetic Orientation of Domestic Dogs · Non-native EMF