  "id": 2511,
  "url": "https://nnemf.org/research/2511-exposure-variability-between-1-or-6-minute-and",
  "title": "Exposure Variability Between 1- or 6-Minute and 30-Minute Averaging Time Lengths in Radiofrequency-Electromagnetic Field Exposure Monitoring",
  "authors": [
    "Bhatt CR, Henderson S, Sanagou M, Loughran S"
  ],
  "journal": "Bioelectromagnetics",
  "year": "2025",
  "doi": "10.1002/bem.70030",
  "pmid": null,
  "abstract": "Category: Bioelectromagnetics, Exposure Assessment Tags: radiofrequency, electromagnetic field, exposure monitoring, averaging time, exposure variability, quantile regression, health risk DOI: 10.1002/bem.70030 URL: https://onlinelibrary.wiley.com/doi/10.1002/bem.70030 Overview Different averaging time lengths (ATLs) are widely used in radiofrequency-electromagnetic field (RF-EMF) exposure monitoring. This study evaluated variability in RF-EMF exposure associated with the ATLs of 1- and 6-min normalised to 30-min data. Methods - RF-EMF exposures were collected in contiguous 1-min blocks over 30 min at four sites (two outdoor and two indoor). - 15 frequency bands of interest were analyzed. - Frequency-band and site-specific variability in exposure between the three ATLs was assessed. Findings - Variability in terms of relative deviation (in dB) between 1- or 6-min and 30-min were estimated. - The overall exposure variability (µW/m2) were compared between 1- or 6-min and 30-min blocks statistically using the quantile regression method. - An ATL of 1-min or 6-min was considered different from 30-min if a majority of respective sub-pair comparisons across different percentiles (P5, P25, P50, P75, P95) were significantly different. Conclusion The study largely showed that the exposure variability (i.e., relative deviation) of different ATLs was within +/- 3 dB. Further, the overall exposure variability between 1- or 6-min and 30-min ATLs showed inconsistent outcomes. Frequency bands of broadcast and most of the mobile services < 2 GHz demonstrated overall similar exposure variability for 1-min and 6-min ATLs. EMF Note: Consistent monitoring and accurate averaging time selections are crucial for understanding and managing health risks associated with RF-EMF exposure, as variability in exposure may affect risk assessments.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "RF · 30 min (contiguous 1-min blocks; comparisons of 1-, 6-, and 30-min averaging time lengths)",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "RF-EMF exposure variability (relative deviation) between 1- or 6-min and 30-min averaging time lengths was largely within ±3 dB. Comparisons of overall exposure variability (µW/m²) between 1- or 6-min and 30-min averaging time lengths showed inconsistent outcomes. Broadcast and most mobile service bands below 2 GHz showed overall similar exposure variability for 1-min and 6-min averaging time lengths.",
    "outcomes": [
      "RF-EMF exposure variability across averaging time lengths (1-",
      "6-",
      "vs 30-min)",
      "Relative deviation (dB) between averaging time lengths",
      "Overall exposure variability (µW/m²) across averaging time lengths",
      "Frequency-band and site-specific differences in exposure variability"
    ],
    "limitations": [],
    "keywords": [
      "radiofrequency",
      "RF-EMF",
      "exposure monitoring",
      "averaging time",
      "exposure variability",
      "quantile regression",
      "frequency bands",
      "indoor",
      "outdoor"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": null,\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"30 min (contiguous 1-min blocks; comparisons of 1-, 6-, and 30-min averaging time lengths)\"\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"RF-EMF exposure variability across averaging time lengths (1-, 6-, vs 30-min)\",\n    \"Relative deviation (dB) between averaging time lengths\",\n    \"Overall exposure variability (µW/m²) across averaging time lengths\",\n    \"Frequency-band and site-specific differences in exposure variability\"\n  ],\n  \"main_findings\": \"RF-EMF exposure variability (relative deviation) between 1- or 6-min and 30-min averaging time lengths was largely within ±3 dB. Comparisons of overall exposure variability (µW/m²) between 1- or 6-min and 30-min averaging time lengths showed inconsistent outcomes. Broadcast and most mobile service bands below 2 GHz showed overall similar exposure variability for 1-min and 6-min averaging time lengths.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"radiofrequency\",\n    \"RF-EMF\",\n    \"exposure monitoring\",\n    \"averaging time\",\n    \"exposure variability\",\n    \"quantile regression\",\n    \"frequency bands\",\n    \"indoor\",\n    \"outdoor\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://onlinelibrary.wiley.com/doi/10.1002/bem.70030",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=2511",
  "updated": "2026-02-12 19:21:56"
}