{
  "id": 2674,
  "url": "https://nnemf.org/research/2674-experimental-study-of-stress-reactions-induced-by-low",
  "title": "Experimental Study of Stress Reactions Induced by Low-Intensity Microwave Radiation",
  "authors": [
    "Izmestieva OS, Kolganova OI, Chibisova OF et al."
  ],
  "journal": "Biological Bulletin of the Russian Academy of Sciences",
  "year": "2024",
  "doi": "10.1134/s1062359024701802",
  "pmid": null,
  "abstract": "Category: Experimental Biology Tags: microwave radiation, electromagnetic fields, stress response, mice, hematopoietic system, adaptation, bioeffects DOI: 10.1134/s1062359024701802 URL: https://link.springer.com/article/10.1134/S1062359024701802 Overview This study investigated how exposure to low-intensity microwave radiation affects the blood system and immune-related organs in mice. Researchers examined several physiological indicators, including: - Number of myelokaryocytes (bone marrow cells) in the femur 🦴 - Level of colony-forming units-spleen (CFU-S) in exo and endotests 🔬 - Hemolytic resistance of erythrocytes 🧬 - Mass and cellularity of the thymus 🫀 Mice were exposed to monochromatic pulsed electromagnetic fields in the 2.27-2.78 GHz frequency range, with an average power flux density of 60 μW/cm² and doses ranging from 0.086 to 0.86 J/g. Findings The study found that repeated exposure to electromagnetic fields caused cumulative biological effects. These effects led to the development of a \"stress-like\" adaptive reaction in the animals, as reflected by changes in the measured blood system and immune organ indicators. Conclusion The experiments demonstrate that repeated low-intensity microwave radiation induces stress reactions and physiological adaptation in mice. The connection between electromagnetic field exposure and biological stress responses highlights the importance of continued research into EMF-related health risks and mechanisms of adaptation.",
  "effect": "harm",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "harm",
    "evidenceLabel": "Low",
    "population": "Mice",
    "sampleSize": "—",
    "exposure": "microwave 1000–3000 MHz",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Repeated exposure to monochromatic pulsed electromagnetic fields (2.27–2.78 GHz; average power flux density 60 μW/cm²; doses 0.086–0.86 J/g) produced cumulative biological effects in mice, described as a “stress-like” adaptive reaction reflected by changes in measured hematopoietic and immune-organ indicators.",
    "outcomes": [
      "Number of myelokaryocytes in femur bone marrow",
      "Colony-forming units-spleen (CFU-S) in exo and endotests",
      "Hemolytic resistance of erythrocytes",
      "Thymus mass and cellularity",
      "Stress-like adaptive reaction / stress response indicators in blood and immune-related organs"
    ],
    "limitations": [
      "Sample size not reported in the provided abstract",
      "Exposure duration/schedule not reported in the provided abstract",
      "No quantitative results or effect sizes provided in the provided abstract",
      "Animal study",
      "human health implications not directly assessed"
    ],
    "keywords": [
      "microwave radiation",
      "electromagnetic fields",
      "pulsed EMF",
      "2.27–2.78 GHz",
      "power flux density",
      "60 μW/cm²",
      "dose",
      "0.086–0.86 J/g",
      "mice",
      "stress response",
      "adaptation",
      "hematopoietic system",
      "bone marrow",
      "CFU-S",
      "erythrocytes",
      "thymus"
    ],
    "hubs": [
      {
        "slug": "who-icnirp",
        "weight": "0.7",
        "reason": "Animal bioeffects study relevant to broader EMF health-risk evidence base often considered in guideline discussions."
      }
    ],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"microwave\",\n    \"source\": null,\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"Mice\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Number of myelokaryocytes in femur bone marrow\",\n    \"Colony-forming units-spleen (CFU-S) in exo and endotests\",\n    \"Hemolytic resistance of erythrocytes\",\n    \"Thymus mass and cellularity\",\n    \"Stress-like adaptive reaction / stress response indicators in blood and immune-related organs\"\n  ],\n  \"main_findings\": \"Repeated exposure to monochromatic pulsed electromagnetic fields (2.27–2.78 GHz; average power flux density 60 μW/cm²; doses 0.086–0.86 J/g) produced cumulative biological effects in mice, described as a “stress-like” adaptive reaction reflected by changes in measured hematopoietic and immune-organ indicators.\",\n  \"effect_direction\": \"harm\",\n  \"limitations\": [\n    \"Sample size not reported in the provided abstract\",\n    \"Exposure duration/schedule not reported in the provided abstract\",\n    \"No quantitative results or effect sizes provided in the provided abstract\",\n    \"Animal study; human health implications not directly assessed\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"microwave radiation\",\n    \"electromagnetic fields\",\n    \"pulsed EMF\",\n    \"2.27–2.78 GHz\",\n    \"power flux density\",\n    \"60 μW/cm²\",\n    \"dose\",\n    \"0.086–0.86 J/g\",\n    \"mice\",\n    \"stress response\",\n    \"adaptation\",\n    \"hematopoietic system\",\n    \"bone marrow\",\n    \"CFU-S\",\n    \"erythrocytes\",\n    \"thymus\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"who-icnirp\",\n      \"weight\": 0.2,\n      \"reason\": \"Animal bioeffects study relevant to broader EMF health-risk evidence base often considered in guideline discussions.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://link.springer.com/article/10.1134/S1062359024701802",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=2674",
  "updated": "2026-02-12 19:23:49"
}