EMF biological effects
Share

Association of Exposure to Radio-Frequency Electromagnetic Field Radiation (RF-EMFR) Generated by Mobile Phone Base Stations with Glycated Hemoglobin (HbA1c) and Risk of Type 2 Diabetes Mellitus

Sultan Ayoub Meo, Yazeed Alsubaie, Zaid Almubarak, Hisham Almutawa, Yazeed AlQasem, Rana Muhammed Hasanato

PAPERmanualInt J Environ Res Public Health2015cross sectionalEffect: harmEvidence: Low

Abstract

Installation of mobile phone base stations in residential areas has initiated public debate about possible adverse effects on human health. This study aimed to determine the association of exposure to radio frequency electromagnetic field radiation (RF-EMFR) generated by mobile phone base stations with glycated hemoglobin (HbA1c) and occurrence of type 2 diabetes mellitus. For this study, two different elementary schools (school-1 and school-2) were selected. We recruited 159 students in total; 96 male students from school-1, with age range 12-16 years, and 63 male students with age range 12-17 years from school-2. Mobile phone base stations with towers existed about 200 m away from the school buildings. RF-EMFR was measured inside both schools. In school-1, RF-EMFR was 9.601 nW/cm² at frequency of 925 MHz, and students had been exposed to RF-EMFR for a duration of 6 h daily, five days in a week. In school-2, RF-EMFR was 1.909 nW/cm² at frequency of 925 MHz and students had been exposed for 6 h daily, five days in a week. 5-6 mL blood was collected from all the students and HbA1c was measured by using a Dimension Xpand Plus Integrated Chemistry System, Siemens. The mean HbA1c for the students who were exposed to high RF-EMFR was significantly higher (5.44 ± 0.22) than the mean HbA1c for the students who were exposed to low RF-EMFR (5.32 ± 0.34) (p = 0.007). Moreover, students who were exposed to high RF-EMFR generated by MPBS had a significantly higher risk of type 2 diabetes mellitus (p = 0.016) relative to their counterparts who were exposed to low RF-EMFR. It is concluded that exposure to high RF-EMFR generated by MPBS is associated with elevated levels of HbA1c and risk of type 2 diabetes mellitus.

AI evidence extraction

At a glance
Study type
cross sectional
Effect direction
harm
Population
Male elementary school students (ages 12–17) from two schools
Sample size
159
Exposure
RF mobile phone base station · 925 MHz · 6 h daily, five days a week
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

RF-EMFR measured inside school-1 was higher (9.601 nW/cm² at 925 MHz) than school-2 (1.909 nW/cm² at 925 MHz). Mean HbA1c was significantly higher in the higher-exposure school (5.44 ± 0.22) than in the lower-exposure school (5.32 ± 0.34) (p = 0.007), and the higher-exposure group had a significantly higher risk of type 2 diabetes mellitus (p = 0.016).

Outcomes measured

  • Glycated hemoglobin (HbA1c)
  • Risk/occurrence of type 2 diabetes mellitus

Limitations

  • Cross-sectional comparison between two schools
  • causality cannot be established
  • Exposure assessment limited to measurements inside schools
  • individual-level exposure variability not described
  • Only male students included
  • Potential confounding factors not described in the abstract
  • Type 2 diabetes mellitus outcome definition/diagnostic criteria not specified in the abstract

Suggested hubs

  • school-wi-fi (0.7)
    Study population is school-based with RF exposure measured inside schools (though source is base stations, not Wi‑Fi).
View raw extracted JSON
{
  "study_type": "cross_sectional",
  "exposure": {
    "band": "RF",
    "source": "mobile phone base station",
    "frequency_mhz": 925,
    "sar_wkg": null,
    "duration": "6 h daily, five days a week"
  },
  "population": "Male elementary school students (ages 12–17) from two schools",
  "sample_size": 159,
  "outcomes": [
    "Glycated hemoglobin (HbA1c)",
    "Risk/occurrence of type 2 diabetes mellitus"
  ],
  "main_findings": "RF-EMFR measured inside school-1 was higher (9.601 nW/cm² at 925 MHz) than school-2 (1.909 nW/cm² at 925 MHz). Mean HbA1c was significantly higher in the higher-exposure school (5.44 ± 0.22) than in the lower-exposure school (5.32 ± 0.34) (p = 0.007), and the higher-exposure group had a significantly higher risk of type 2 diabetes mellitus (p = 0.016).",
  "effect_direction": "harm",
  "limitations": [
    "Cross-sectional comparison between two schools; causality cannot be established",
    "Exposure assessment limited to measurements inside schools; individual-level exposure variability not described",
    "Only male students included",
    "Potential confounding factors not described in the abstract",
    "Type 2 diabetes mellitus outcome definition/diagnostic criteria not specified in the abstract"
  ],
  "evidence_strength": "low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "RF-EMFR",
    "radiofrequency",
    "mobile phone base stations",
    "school exposure",
    "HbA1c",
    "type 2 diabetes mellitus",
    "925 MHz"
  ],
  "suggested_hubs": [
    {
      "slug": "school-wi-fi",
      "weight": 0.35,
      "reason": "Study population is school-based with RF exposure measured inside schools (though source is base stations, not Wi‑Fi)."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 2725

Association of Exposure to Radio-Frequency Electromagnetic Field Radiation (RF-EMFR) Generated by Mobile Phone Base Stations with Glycated Hemoglobin (HbA1c) and Risk of Type 2 Diabetes Mellitus · Non-native EMF