The Effectiveness of a Conductive Patch and a Conductive Bed Pad in Reducing Induced Human Body Voltage Via the Application of Earth Ground
Abstract
Voltage induced on a human body by capacitive coupling to the external environment was measured using a high-impedance measurement head. The body was then earth grounded by means of a Conductive Patch and a Conductive Bed Pad. Each method reduced the coupled 60Hz mains voltage by a factor of at least 70. This result, along with the measurement of the voltage drop across an in-line resistance in the Conductive Patch provided evidence of a simplified electrical network model of the human body.
AI evidence extraction
Main findings
Voltage induced on a human body via capacitive coupling was measured, then the body was earth grounded using a conductive patch and a conductive bed pad. Each grounding method reduced coupled 60 Hz mains voltage by a factor of at least 70. A measured voltage drop across an in-line resistance in the conductive patch was reported as evidence supporting a simplified electrical network model of the human body.
Outcomes measured
- Induced human body voltage (60 Hz mains)
- Voltage drop across in-line resistance (conductive patch)
Limitations
- Sample size and participant characteristics not stated in abstract
- Study design details (controls
- blinding
- measurement conditions) not described in abstract
- Only 60 Hz mains voltage reduction reported
- broader exposure conditions not addressed
Suggested hubs
- occupational-exposure (0.7)Study concerns 60 Hz mains-related induced body voltage, which can be relevant to occupational/indoor electrical environments, though no workplace setting is specified.
View raw extracted JSON
{
"study_type": "exposure_assessment",
"exposure": {
"band": "ELF",
"source": "mains electricity / capacitive coupling to external environment",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": "human body (unspecified participants)",
"sample_size": null,
"outcomes": [
"Induced human body voltage (60 Hz mains)",
"Voltage drop across in-line resistance (conductive patch)"
],
"main_findings": "Voltage induced on a human body via capacitive coupling was measured, then the body was earth grounded using a conductive patch and a conductive bed pad. Each grounding method reduced coupled 60 Hz mains voltage by a factor of at least 70. A measured voltage drop across an in-line resistance in the conductive patch was reported as evidence supporting a simplified electrical network model of the human body.",
"effect_direction": "benefit",
"limitations": [
"Sample size and participant characteristics not stated in abstract",
"Study design details (controls, blinding, measurement conditions) not described in abstract",
"Only 60 Hz mains voltage reduction reported; broader exposure conditions not addressed"
],
"evidence_strength": "very_low",
"confidence": 0.66,
"peer_reviewed_likely": "unknown",
"keywords": [
"earthing",
"grounding",
"conductive patch",
"conductive bed pad",
"induced body voltage",
"capacitive coupling",
"60 Hz",
"mains voltage",
"ELF"
],
"suggested_hubs": [
{
"slug": "occupational-exposure",
"weight": 0.2,
"reason": "Study concerns 60 Hz mains-related induced body voltage, which can be relevant to occupational/indoor electrical environments, though no workplace setting is specified."
}
]
}AI can be wrong. Always verify against the paper.
Comments
Log in to comment.
No comments yet.
NNEMF synthesis
Synthesis pending.