  "id": 2732,
  "url": "https://nnemf.org/research/2732-the-effectiveness-of-a-conductive-patch-and-a",
  "title": "The Effectiveness of a Conductive Patch and a Conductive Bed Pad in Reducing Induced Human Body Voltage Via the Application of Earth Ground",
  "authors": [
    "Roger Applewhite"
  ],
  "journal": "European Biology and Bioelectromagnetics",
  "year": "2005",
  "doi": null,
  "pmid": null,
  "abstract": "Voltage induced on a human body by capacitive coupling to the external environment was measured using a high-impedance measurement head. The body was then earth grounded by means of a Conductive Patch and a Conductive Bed Pad. Each method reduced the coupled 60Hz mains voltage by a factor of at least 70. This result, along with the measurement of the voltage drop across an in-line resistance in the Conductive Patch provided evidence of a simplified electrical network model of the human body.",
  "effect": "benefit",
  "evidence": "very_low",
  "extraction": {
    "studyType": "exposure_assessment",
    "studyTypeLabel": "exposure assessment",
    "effectDirection": "benefit",
    "evidenceLabel": "Very low",
    "population": "human body (unspecified participants)",
    "sampleSize": "—",
    "exposure": "ELF <1 MHz",
    "confidencePct": "66",
    "peerReviewed": "unknown",
    "mainFindings": "Voltage induced on a human body via capacitive coupling was measured, then the body was earth grounded using a conductive patch and a conductive bed pad. Each grounding method reduced coupled 60 Hz mains voltage by a factor of at least 70. A measured voltage drop across an in-line resistance in the conductive patch was reported as evidence supporting a simplified electrical network model of the human body.",
    "outcomes": [
      "Induced human body voltage (60 Hz mains)",
      "Voltage drop across in-line resistance (conductive patch)"
    ],
    "limitations": [
      "Sample size and participant characteristics not stated in abstract",
      "Study design details (controls",
      "blinding",
      "measurement conditions) not described in abstract",
      "Only 60 Hz mains voltage reduction reported",
      "broader exposure conditions not addressed"
    ],
    "keywords": [
      "earthing",
      "grounding",
      "conductive patch",
      "conductive bed pad",
      "induced body voltage",
      "capacitive coupling",
      "60 Hz",
      "mains voltage",
      "ELF"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Study concerns 60 Hz mains-related induced body voltage, which can be relevant to occupational/indoor electrical environments, though no workplace setting is specified."
      }
    ],
    "raw": "{\n  \"study_type\": \"exposure_assessment\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": \"mains electricity / capacitive coupling to external environment\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"human body (unspecified participants)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Induced human body voltage (60 Hz mains)\",\n    \"Voltage drop across in-line resistance (conductive patch)\"\n  ],\n  \"main_findings\": \"Voltage induced on a human body via capacitive coupling was measured, then the body was earth grounded using a conductive patch and a conductive bed pad. Each grounding method reduced coupled 60 Hz mains voltage by a factor of at least 70. A measured voltage drop across an in-line resistance in the conductive patch was reported as evidence supporting a simplified electrical network model of the human body.\",\n  \"effect_direction\": \"benefit\",\n  \"limitations\": [\n    \"Sample size and participant characteristics not stated in abstract\",\n    \"Study design details (controls, blinding, measurement conditions) not described in abstract\",\n    \"Only 60 Hz mains voltage reduction reported; broader exposure conditions not addressed\"\n  ],\n  \"evidence_strength\": \"very_low\",\n  \"confidence\": 0.66,\n  \"peer_reviewed_likely\": \"unknown\",\n  \"keywords\": [\n    \"earthing\",\n    \"grounding\",\n    \"conductive patch\",\n    \"conductive bed pad\",\n    \"induced body voltage\",\n    \"capacitive coupling\",\n    \"60 Hz\",\n    \"mains voltage\",\n    \"ELF\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.2,\n      \"reason\": \"Study concerns 60 Hz mains-related induced body voltage, which can be relevant to occupational/indoor electrical environments, though no workplace setting is specified.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://earthinginstitute.net/wp-content/uploads/2019/12/Applewhite-Body-Voltage-study.pdf",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=2732",
  "updated": "2026-02-13 02:35:19"
}