EMF biological effects
Share

Magnetic characterization of Mumetal® for passive shielding of stray fields down to the nano-Tesla level

Pasquale Arpaia, Philip Nicholas Burrows, Marco Buzio, Chetan Gohil, Mariano Pentella, Daniel Schulte

PAPERmanualNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment2021engineeringEffect: benefitEvidence: Moderate

Abstract

The luminosity of a particle collider is an extremely crucial performance parameter describing its capability of producing interactions in the collision point. However, imperfections in a collider can lead to luminosity loss. Among different imperfections, an important one is stray magnetic fields. For the Compact Linear Collider (CLIC), a collider being considered as one of the main options in Europe after the Large Hadron Collider, simulations showed an unprecedented sensitivity of the machine to fields on the order of 0.1 nT. Hence, such tight constraints require special design considerations to prevent performance loss. Different shielding techniques are available in the literature, typically relying on an active shielding strategy and capable of reducing the magnetic field amplitudes down to the nano-Tesla level. However, measuring fields with such amplitudes is challenging by using state-of-the-art commercially available sensors and therefore, a passive shielding strategy, consisting in enveloping sections of the beamline with a magnetic shield, is a more attractive option. For CLIC, Mumetal®, a Ni–Fe alloy with advertised relative permeability above 100,000, was chosen. In this paper, the DC and AC magnetic characterization of two samples of Mumetal®, one annealed in its final form and the other one non-annealed is presented, showcasing how the annealing results in a boost of the magnetic permeability of more than order of magnitude. As a case study, the shielding performance of a 1-mm thin layer of Mumetal® enveloping CLIC’s beamline is estimated. Effect: Positive

AI evidence extraction

At a glance
Study type
engineering
Effect direction
benefit
Population
—
Sample size
2
Exposure
stray magnetic fields
Evidence strength
Moderate
Confidence: 70% · Peer-reviewed: yes

Main findings

Annealing Mumetal® significantly increases its magnetic permeability by more than an order of magnitude. A 1-mm thin layer of annealed Mumetal® can effectively shield stray magnetic fields down to the nano-Tesla level around the CLIC beamline.

Outcomes measured

  • magnetic permeability
  • shielding performance

Limitations

  • Study focused on material characterization and simulation estimates
  • not in situ collider performance data.
  • Only two samples tested
  • limiting generalizability.
  • Shielding performance estimated rather than empirically measured in operational conditions.

Suggested hubs

  • occupational-exposure (0.7)
    Related to magnetic field exposure and shielding in particle accelerator environments.
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": null,
    "source": "stray magnetic fields",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": 2,
  "outcomes": [
    "magnetic permeability",
    "shielding performance"
  ],
  "main_findings": "Annealing Mumetal® significantly increases its magnetic permeability by more than an order of magnitude. A 1-mm thin layer of annealed Mumetal® can effectively shield stray magnetic fields down to the nano-Tesla level around the CLIC beamline.",
  "effect_direction": "benefit",
  "limitations": [
    "Study focused on material characterization and simulation estimates, not in situ collider performance data.",
    "Only two samples tested, limiting generalizability.",
    "Shielding performance estimated rather than empirically measured in operational conditions."
  ],
  "evidence_strength": "moderate",
  "confidence": 0.7,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "Mumetal",
    "magnetic shielding",
    "stray magnetic fields",
    "nano-Tesla",
    "Compact Linear Collider",
    "magnetic permeability",
    "passive shielding"
  ],
  "suggested_hubs": [
    {
      "slug": "occupational-exposure",
      "weight": 0.3,
      "reason": "Related to magnetic field exposure and shielding in particle accelerator environments."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 2733

Magnetic characterization of Mumetal® for passive shielding of stray fields down to the nano-Tesla level · Non-native EMF