  "id": 2786,
  "url": "https://nnemf.org/research/2786-the-effect-of-postoperative-immobilization-on-the-healing",
  "title": "The effect of postoperative immobilization on the healing of radiofrequency heat probe modified tissue: assessment of tissue length, stiffness, and morphology.",
  "authors": [
    "Theodore F Schlegel",
    "Kenneth J Faber",
    "Andrew L Chen",
    "Richard J Hawkins"
  ],
  "journal": "Orthopedics",
  "year": "2008",
  "doi": "10.3928/01477447-20080201-30",
  "pmid": "19292208",
  "abstract": "The effect of postoperative immobilization on the length, stiffness, and structure of connective tissue after radiofrequency probe shrinkage was examined in a rabbit patellar tendon model. Tendon lengths were measured before, immediately following, and 2, 4, and 8 weeks following heat application, with the contralateral tendon as a control. The animals were randomly assigned to three groups. In Group I, the controls, the animals were allowed free caged activity for 8 weeks. In Groups II and III, the experimental limb was immobilized at 15 degrees of knee flexion for 2 and 4 weeks, respectively, after which the animals were allowed 6 and 4 weeks of free caged activity. Changes in tendon length, stiffness, and cross-sectional area were compared using repeated measures ANOVA and differences between groups examined using Tukey's post-hoc analysis. Patellar tendon lengths were increased in all 3 groups at 8 weeks (P< .001). Tissue elongation was less extensive in group III compared to group I at 8 weeks (P< .001), while tissue cross-sectional area was decreased in both groups II and III compared to group I at 8 weeks (P< .001). All groups demonstrated decreases in tensile strength when compared to controls (P< .001). These findings suggest that postoperative immobilization is important following thermal shrinkage of connective tissue, as early activity can lead to stretching of the heat-modified tissue.",
  "effect": "mixed",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "mixed",
    "evidenceLabel": "Low",
    "population": "Rabbits (rabbit patellar tendon model)",
    "sampleSize": "—",
    "exposure": "RF",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "In a rabbit patellar tendon model after radiofrequency probe shrinkage, patellar tendon lengths increased in all groups at 8 weeks. Elongation was less in the 4-week immobilization group versus free-activity controls, and cross-sectional area was decreased in both immobilization groups versus controls at 8 weeks. All groups showed decreases in tensile strength compared to controls.",
    "outcomes": [
      "Tendon length",
      "Tendon stiffness",
      "Tissue morphology/structure",
      "Cross-sectional area",
      "Tensile strength"
    ],
    "limitations": [
      "Sample size not reported in abstract",
      "Radiofrequency exposure parameters (e.g.",
      "frequency",
      "power",
      "SAR) not reported",
      "Animal model",
      "generalizability to humans unclear",
      "Control condition described as contralateral tendon and free-activity group",
      "details of control comparisons not fully specified in abstract"
    ],
    "keywords": [
      "radiofrequency heat probe",
      "thermal shrinkage",
      "postoperative immobilization",
      "rabbit model",
      "patellar tendon",
      "tendon length",
      "stiffness",
      "cross-sectional area",
      "tensile strength",
      "connective tissue"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"radiofrequency heat probe\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"Rabbits (rabbit patellar tendon model)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Tendon length\",\n    \"Tendon stiffness\",\n    \"Tissue morphology/structure\",\n    \"Cross-sectional area\",\n    \"Tensile strength\"\n  ],\n  \"main_findings\": \"In a rabbit patellar tendon model after radiofrequency probe shrinkage, patellar tendon lengths increased in all groups at 8 weeks. Elongation was less in the 4-week immobilization group versus free-activity controls, and cross-sectional area was decreased in both immobilization groups versus controls at 8 weeks. All groups showed decreases in tensile strength compared to controls.\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [\n    \"Sample size not reported in abstract\",\n    \"Radiofrequency exposure parameters (e.g., frequency, power, SAR) not reported\",\n    \"Animal model; generalizability to humans unclear\",\n    \"Control condition described as contralateral tendon and free-activity group; details of control comparisons not fully specified in abstract\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"radiofrequency heat probe\",\n    \"thermal shrinkage\",\n    \"postoperative immobilization\",\n    \"rabbit model\",\n    \"patellar tendon\",\n    \"tendon length\",\n    \"stiffness\",\n    \"cross-sectional area\",\n    \"tensile strength\",\n    \"connective tissue\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/19292208/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=2786",
  "updated": "2026-02-13 06:47:57"
}