Share

A new approach for explanation of specimen rupture under high electric field.

I M Mikhailovskij, N Wanderka, V E Storizhko, V A Ksenofontov, T I Mazilova

PAPERpubmedUltramicroscopy2009engineeringEffect: unclearEvidence: Insufficient

Abstract

Failure of needle-shaped specimens under the action of high electric fields is one of the most serious problems in many field-ionization devices and methods. It was shown that the length of what was removed during discharge part of specimens in most of the cases was several orders greater than that of an initial radius of the specimen apex. Experimental results obtained in this work indicate that electrical breakdown in field-ion microscopes is initiated by the impact of nanoparticles detached from a point anode in a high electric field. A new approach for explanation of an observed specimen failure in a high electric field was proposed, where the formation and expansion of the cathode plasma play the key role in the mechanical rupture and melting of field-ion tips. The expanding plasma behaves as a dynamic capacitor plate characterized by a high velocity and increasing field strength at the specimen tip. The field rise rate at a constant voltage in a dynamic plasma-to-tip capacitor is of the order of >10(20)V/m/s. The present experimental data along with the ecton model of the vacuum breakdown allow the results to be discussed as a mechanical sample failure under the action of the superhigh positive field pulse induced by the cathode plasma expansion.

AI evidence extraction

At a glance
Study type
engineering
Effect direction
unclear
Population
—
Sample size
—
Exposure
field-ion microscope / field-ionization device
Evidence strength
Insufficient
Confidence: 78% · Peer-reviewed: yes

Main findings

Experimental results indicate that electrical breakdown in field-ion microscopes is initiated by impact of nanoparticles detached from a point anode in a high electric field. The authors propose that cathode plasma formation and expansion drives mechanical rupture and melting by acting like a dynamic capacitor plate that increases field strength at the specimen tip, with a reported field rise rate at constant voltage of >10^20 V/m/s.

Outcomes measured

  • Specimen rupture/failure of needle-shaped tips under high electric field
  • Mechanical rupture and melting of field-ion tips
  • Electrical breakdown initiation mechanisms in field-ion microscopes

Limitations

  • No biological/health outcomes assessed (materials/device failure context)
  • Sample size and quantitative breakdown/failure rates are not provided in the abstract
  • Exposure parameters such as frequency or time course beyond qualitative descriptions are not specified
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": null,
    "source": "field-ion microscope / field-ionization device",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "Specimen rupture/failure of needle-shaped tips under high electric field",
    "Mechanical rupture and melting of field-ion tips",
    "Electrical breakdown initiation mechanisms in field-ion microscopes"
  ],
  "main_findings": "Experimental results indicate that electrical breakdown in field-ion microscopes is initiated by impact of nanoparticles detached from a point anode in a high electric field. The authors propose that cathode plasma formation and expansion drives mechanical rupture and melting by acting like a dynamic capacitor plate that increases field strength at the specimen tip, with a reported field rise rate at constant voltage of >10^20 V/m/s.",
  "effect_direction": "unclear",
  "limitations": [
    "No biological/health outcomes assessed (materials/device failure context)",
    "Sample size and quantitative breakdown/failure rates are not provided in the abstract",
    "Exposure parameters such as frequency or time course beyond qualitative descriptions are not specified"
  ],
  "evidence_strength": "insufficient",
  "confidence": 0.78,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "high electric field",
    "field-ion microscope",
    "vacuum breakdown",
    "cathode plasma expansion",
    "nanoparticles",
    "specimen rupture",
    "ecton model",
    "dynamic capacitor",
    "field pulse"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 2830

A new approach for explanation of specimen rupture under high electric field. · Non-native EMF