  "id": 2846,
  "url": "https://nnemf.org/research/2846-delivery-of-patient-reported-outcome-instruments-by-automated",
  "title": "Delivery of Patient-Reported Outcome Instruments by Automated Mobile Phone Text Messaging.",
  "authors": [
    "Christopher A Anthony",
    "Ericka A Lawler",
    "Natalie A Glass",
    "Katelyn McDonald",
    "Apurva S Shah"
  ],
  "journal": "Hand (New York, N.Y.)",
  "year": "2017",
  "doi": "10.1177/1558944716672201",
  "pmid": "29091492",
  "abstract": "BACKGROUND: Patient-reported outcome (PRO) instruments allow patients to interpret their health and are integral in evaluating orthopedic treatments and outcomes. The purpose of this study was to define: (1) correlation between PROs collected by automated delivery of text messages on mobile phones compared with paper delivery; and (2) patient use characteristics of a technology platform utilizing automated delivery of text messages on mobile phones. METHODS: Paper versions of the 12-Item Short Form Health Survey (SF-12) and the short form of the Disabilities of the Arm, Shoulder and Hand (QuickDASH) were completed by patients in orthopedic hand and upper extremity clinics. Over the next 48 hours, the same patients also completed the mobile phone portion of the study outside of the clinic which included text message delivery of the SF-12 and QuickDASH, assigned in a random order. Correlations between paper and text message delivery of the 2 PROs were assessed. RESULTS: Among 72 patients, the intraclass correlation coefficient (ICC) between the written and mobile phone delivery of QuickDASH was 0.91 (95% confidence interval [CI], 0.85-0.95). The ICC between the paper and mobile phone delivery of the SF-12 physical health composite score was 0.88 (95% CI, 0.79-0.93) and 0.86 (95% CI, 0.75-0.92) for the SF-12 mental health composite score. CONCLUSIONS: We find that text message delivery using mobile phones permits valid assessment of SF-12 and QuickDASH scores. The findings suggest that software-driven automated delivery of text communication to patients via mobile phones may be a valid method to obtain other PRO scores in orthopedic patients.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "other",
    "studyTypeLabel": "Other",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "Patients in orthopedic hand and upper extremity clinics",
    "sampleSize": "72",
    "exposure": "mobile phone · text message delivery of PRO instruments over the next 48 hours",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "In 72 patients, agreement between paper and mobile phone text message delivery was high: QuickDASH ICC 0.91 (95% CI 0.85–0.95); SF-12 physical ICC 0.88 (95% CI 0.79–0.93); SF-12 mental ICC 0.86 (95% CI 0.75–0.92). Authors conclude text message delivery permits valid assessment of SF-12 and QuickDASH scores.",
    "outcomes": [
      "Correlation/agreement (intraclass correlation coefficient) between paper vs mobile phone text message delivery of QuickDASH",
      "Correlation/agreement (intraclass correlation coefficient) between paper vs mobile phone text message delivery of SF-12 physical health composite score",
      "Correlation/agreement (intraclass correlation coefficient) between paper vs mobile phone text message delivery of SF-12 mental health composite score",
      "Patient use characteristics of an automated text messaging platform (details not provided in abstract)"
    ],
    "limitations": [
      "No EMF/RF exposure metrics reported (e.g.",
      "frequency",
      "SAR",
      "field strength)",
      "Clinical/measurement validation study rather than a health-effects study",
      "Patient use characteristics mentioned but not described in the abstract"
    ],
    "keywords": [
      "patient-reported outcomes",
      "text messaging",
      "mobile phone",
      "SF-12",
      "QuickDASH",
      "orthopedic clinic",
      "instrument validation",
      "intraclass correlation"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"other\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"mobile phone\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"text message delivery of PRO instruments over the next 48 hours\"\n  },\n  \"population\": \"Patients in orthopedic hand and upper extremity clinics\",\n  \"sample_size\": 72,\n  \"outcomes\": [\n    \"Correlation/agreement (intraclass correlation coefficient) between paper vs mobile phone text message delivery of QuickDASH\",\n    \"Correlation/agreement (intraclass correlation coefficient) between paper vs mobile phone text message delivery of SF-12 physical health composite score\",\n    \"Correlation/agreement (intraclass correlation coefficient) between paper vs mobile phone text message delivery of SF-12 mental health composite score\",\n    \"Patient use characteristics of an automated text messaging platform (details not provided in abstract)\"\n  ],\n  \"main_findings\": \"In 72 patients, agreement between paper and mobile phone text message delivery was high: QuickDASH ICC 0.91 (95% CI 0.85–0.95); SF-12 physical ICC 0.88 (95% CI 0.79–0.93); SF-12 mental ICC 0.86 (95% CI 0.75–0.92). Authors conclude text message delivery permits valid assessment of SF-12 and QuickDASH scores.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No EMF/RF exposure metrics reported (e.g., frequency, SAR, field strength)\",\n    \"Clinical/measurement validation study rather than a health-effects study\",\n    \"Patient use characteristics mentioned but not described in the abstract\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"patient-reported outcomes\",\n    \"text messaging\",\n    \"mobile phone\",\n    \"SF-12\",\n    \"QuickDASH\",\n    \"orthopedic clinic\",\n    \"instrument validation\",\n    \"intraclass correlation\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/29091492/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=2846",
  "updated": "2026-02-13 06:54:08"
}