{
  "id": 2860,
  "url": "https://nnemf.org/research/2860-influence-of-growth-rate-and-magnetic-field-on",
  "title": "Influence of Growth Rate and Magnetic Field on Microstructure and Properties of Directionally Solidified Ag-Cu Eutectic Alloy.",
  "authors": [
    "Xiaowei Zuo",
    "Congcong Zhao",
    "Lin Zhang",
    "Engang Wang"
  ],
  "journal": "Materials (Basel, Switzerland)",
  "year": "2016",
  "doi": "10.3390/ma9070569",
  "pmid": "28773691",
  "abstract": "We report the influence of growth rate and external magnetic field on the eutectic lamellar spacing and properties of directionally-solidified Ag-Cu eutectic alloys. The results indicated that the relationship between the lamellar spacing of directionally-solidified Ag-Cu alloys and the growth rate matched the prediction of the Jackson-Hunt model, and the constant was 5.8 µm³/s. The increasing external magnetic field during solidification tilted the growth direction of the lamellar eutectics, and coarsened the eutectic lamellar spacing. These decreased the microhardness and strength of Ag-Cu alloys, but increased their electrical conductivity. The competitive strengthening contributions between the refinement of the eutectic lamellar spacing and the change in growth direction of the eutectics resulted in higher strength in the as-rolled sample with a 0.8 T magnetic field than with other samples, which was confirmed from higher relieved deformation energy using differential scanning calorimetry.",
  "effect": "mixed",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "mixed",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "external magnetic field during solidification",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "In directionally solidified Ag-Cu eutectic alloys, increasing external magnetic field during solidification tilted the growth direction of lamellar eutectics and coarsened eutectic lamellar spacing. These changes decreased microhardness and strength but increased electrical conductivity. An as-rolled sample with a 0.8 T magnetic field showed higher strength than other samples, supported by higher relieved deformation energy on differential scanning calorimetry.",
    "outcomes": [
      "eutectic lamellar spacing",
      "growth direction/tilting of lamellar eutectics",
      "microhardness",
      "strength",
      "electrical conductivity",
      "relieved deformation energy (differential scanning calorimetry)"
    ],
    "limitations": [
      "Magnetic field frequency/waveform not described (only field strength mentioned).",
      "No sample size or detailed experimental design information provided in the abstract.",
      "Findings are for material microstructure/properties",
      "no biological/health outcomes assessed."
    ],
    "keywords": [
      "Ag-Cu eutectic alloy",
      "directional solidification",
      "growth rate",
      "external magnetic field",
      "lamellar spacing",
      "microhardness",
      "strength",
      "electrical conductivity",
      "Jackson-Hunt model",
      "differential scanning calorimetry"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"external magnetic field during solidification\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"eutectic lamellar spacing\",\n    \"growth direction/tilting of lamellar eutectics\",\n    \"microhardness\",\n    \"strength\",\n    \"electrical conductivity\",\n    \"relieved deformation energy (differential scanning calorimetry)\"\n  ],\n  \"main_findings\": \"In directionally solidified Ag-Cu eutectic alloys, increasing external magnetic field during solidification tilted the growth direction of lamellar eutectics and coarsened eutectic lamellar spacing. These changes decreased microhardness and strength but increased electrical conductivity. An as-rolled sample with a 0.8 T magnetic field showed higher strength than other samples, supported by higher relieved deformation energy on differential scanning calorimetry.\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [\n    \"Magnetic field frequency/waveform not described (only field strength mentioned).\",\n    \"No sample size or detailed experimental design information provided in the abstract.\",\n    \"Findings are for material microstructure/properties; no biological/health outcomes assessed.\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"Ag-Cu eutectic alloy\",\n    \"directional solidification\",\n    \"growth rate\",\n    \"external magnetic field\",\n    \"lamellar spacing\",\n    \"microhardness\",\n    \"strength\",\n    \"electrical conductivity\",\n    \"Jackson-Hunt model\",\n    \"differential scanning calorimetry\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"engineering-materials-processing\",\n      \"weight\": 0.9,\n      \"reason\": \"Study examines effects of an external magnetic field (0.8 T mentioned) on alloy solidification microstructure and properties.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/28773691/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=2860",
  "updated": "2026-02-13 06:54:18"
}