  "title": "Ultrafast volumetric B1 (+) mapping for improved radiofrequency shimming in 3 tesla body MRI.",
  "authors": [
    "Alois M Sprinkart",
    "Kay Nehrke",
    "Frank Träber",
    "Wolfgang Block",
    "Jürgen Gieseke",
    "Georg Schmitz",
    "Winfried A Willinek",
    "Hans Schild",
    "Peter Börnert"
  ],
  "journal": "Journal of magnetic resonance imaging : JMRI",
  "year": "2014",
  "doi": "10.1002/jmri.24438",
  "pmid": "24924914",
  "abstract": "PURPOSE: To evaluate the use of the recently proposed ultrafast B1 (+) mapping approach DREAM (Dual Refocusing Echo Acquisition Mode) for a refinement of patient adaptive radiofrequency (RF) shimming. MATERIALS AND METHODS: Volumetric DREAM B1 (+) calibration scans centered in the upper abdomen were acquired in 20 patients and three volunteers with written informed consent at a clinical dual source 3 Tesla (T) MR system. Based on these data, RF transmit settings were optimized by central-slice based RF-shimming (CS-RF shim) and by a refined, multi-slice adaptive approach (MS-RF shim). Simulations were performed to compare flip angle accuracy and B1 (+) homogeneity (cv = stddev/mean) achieved by CS-RF shim versus MS-RF shim for transversal and coronal slices, and for volume shimming on the spine. RESULTS: By MS-RF shim, mean deviation from nominal flip angle was reduced to less than 11% in all slices, all targets, and all subjects. Relative improvements in B1 (+) cv (MS-RF shim versus CS-RF) were up to 14%/39%/47% in transversal slices/coronal slices/ spine area. CONCLUSION: Volumetric information about B1 (+) can be used to further improve the accuracy and homogeneity of the B1 (+) field yielding higher diagnostic confidence, and will also be of value for various quantitative methods which are sensitive to flip angle imperfections.",
  "effect": "benefit",
  "evidence": "low",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "benefit",
    "evidenceLabel": "Low",
    "population": "20 patients and three volunteers",
    "sampleSize": "23",
    "exposure": "RF",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Using multi-slice adaptive RF shimming (MS-RF shim) based on volumetric DREAM B1+ calibration scans, mean deviation from nominal flip angle was reduced to less than 11% across slices/targets/subjects. Relative improvements in B1+ homogeneity (cv) for MS-RF shim versus central-slice RF shimming were reported up to 14% (transversal), 39% (coronal), and 47% (spine area).",
    "outcomes": [
      "B1+ mapping performance (DREAM)",
      "Flip angle accuracy (deviation from nominal)",
      "B1+ homogeneity (coefficient of variation",
      "cv)",
      "Performance of RF shimming approaches (CS-RF shim vs MS-RF shim)"
    ],
    "limitations": [],
    "keywords": [
      "B1+ mapping",
      "DREAM",
      "Dual Refocusing Echo Acquisition Mode",
      "radiofrequency shimming",
      "RF transmit settings",
      "3 Tesla",
      "body MRI",
      "flip angle",
      "B1+ homogeneity",
      "upper abdomen"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"MRI\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"20 patients and three volunteers\",\n  \"sample_size\": 23,\n  \"outcomes\": [\n    \"B1+ mapping performance (DREAM)\",\n    \"Flip angle accuracy (deviation from nominal)\",\n    \"B1+ homogeneity (coefficient of variation, cv)\",\n    \"Performance of RF shimming approaches (CS-RF shim vs MS-RF shim)\"\n  ],\n  \"main_findings\": \"Using multi-slice adaptive RF shimming (MS-RF shim) based on volumetric DREAM B1+ calibration scans, mean deviation from nominal flip angle was reduced to less than 11% across slices/targets/subjects. Relative improvements in B1+ homogeneity (cv) for MS-RF shim versus central-slice RF shimming were reported up to 14% (transversal), 39% (coronal), and 47% (spine area).\",\n  \"effect_direction\": \"benefit\",\n  \"limitations\": [],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"B1+ mapping\",\n    \"DREAM\",\n    \"Dual Refocusing Echo Acquisition Mode\",\n    \"radiofrequency shimming\",\n    \"RF transmit settings\",\n    \"3 Tesla\",\n    \"body MRI\",\n    \"flip angle\",\n    \"B1+ homogeneity\",\n    \"upper abdomen\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"mri-rf\",\n      \"weight\": 0.9,\n      \"reason\": \"Study evaluates RF (B1+) mapping and RF shimming methods in a 3T clinical MRI system.\"\n    }\n  ]\n}"
  },