  "title": "A mm-sized wirelessly powered and remotely controlled locomotive implant.",
  "authors": [
    "Daniel Pivonka",
    "Anatoly Yakovlev",
    "Ada S Y Poon",
    "Teresa Meng"
  ],
  "journal": "IEEE transactions on biomedical circuits and systems",
  "year": "2012",
  "doi": "10.1109/tbcas.2012.2232665",
  "pmid": "23853253",
  "abstract": "A wirelessly powered and controlled implantable device capable of locomotion in a fluid medium is presented. Two scalable low-power propulsion methods are described that achieve roughly an order of magnitude better performance than existing methods in terms of thrust conversion efficiency. The wireless prototype occupies 0.6 mm × 1 mm in 65 nm CMOS with an external 2 mm × 2 mm receive antenna. The IC consists of a matching network, a rectifier, a bandgap reference, a regulator, a demodulator, a digital controller, and high-current drivers that interface directly with the propulsion system. It receives 500 μW from a 2 W 1.86 GHz power signal at a distance of 5 cm. Asynchronous pulse-width modulation on the carrier allows for data rates from 2.5-25 Mbps with energy efficiency of 0.5 pJ/b at 10 Mbps. The received data configures the propulsion system drivers, which are capable of driving up to 2 mA at 0.2 V and can achieve speed of 0.53 cm/sec in a 0.06 T magnetic field.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "RF wireless power signal (implantable device) · 1860 MHz",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "A mm-scale implantable locomotive device was wirelessly powered and controlled. The prototype received 500 µW from a 2 W, 1.86 GHz power signal at 5 cm distance and supported 2.5–25 Mbps data rates via asynchronous PWM on the carrier; the propulsion drivers enabled locomotion up to 0.53 cm/s in a 0.06 T magnetic field.",
    "outcomes": [
      "Wireless power transfer performance (received power at distance)",
      "Implant device locomotion/propulsion performance (speed",
      "thrust conversion efficiency)",
      "Wireless data communication performance (data rate",
      "energy efficiency)"
    ],
    "limitations": [
      "No biological/health outcomes are reported in the abstract.",
      "No exposure metrics such as SAR or tissue heating are reported.",
      "Study context appears to be device engineering",
      "population/sample details are not provided."
    ],
    "keywords": [
      "wireless power transfer",
      "implantable device",
      "locomotion",
      "CMOS",
      "1.86 GHz",
      "RF power signal",
      "asynchronous PWM",
      "data rate",
      "energy efficiency",
      "magnetic field"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"wireless power signal (implantable device)\",\n    \"frequency_mhz\": 1860,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Wireless power transfer performance (received power at distance)\",\n    \"Implant device locomotion/propulsion performance (speed, thrust conversion efficiency)\",\n    \"Wireless data communication performance (data rate, energy efficiency)\"\n  ],\n  \"main_findings\": \"A mm-scale implantable locomotive device was wirelessly powered and controlled. The prototype received 500 µW from a 2 W, 1.86 GHz power signal at 5 cm distance and supported 2.5–25 Mbps data rates via asynchronous PWM on the carrier; the propulsion drivers enabled locomotion up to 0.53 cm/s in a 0.06 T magnetic field.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No biological/health outcomes are reported in the abstract.\",\n    \"No exposure metrics such as SAR or tissue heating are reported.\",\n    \"Study context appears to be device engineering; population/sample details are not provided.\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"wireless power transfer\",\n    \"implantable device\",\n    \"locomotion\",\n    \"CMOS\",\n    \"1.86 GHz\",\n    \"RF power signal\",\n    \"asynchronous PWM\",\n    \"data rate\",\n    \"energy efficiency\",\n    \"magnetic field\"\n  ],\n  \"suggested_hubs\": []\n}"
  },