{
  "id": 3138,
  "url": "https://nnemf.org/research/3138-use-of-a-hip-arthroscopy-flexible-radiofrequency-device",
  "title": "Use of a hip arthroscopy flexible radiofrequency device for capsular release in frozen shoulder.",
  "authors": [
    "Stephen R Thompson",
    "Marie-Eve Lebel"
  ],
  "journal": "Arthroscopy techniques",
  "year": "2012",
  "doi": "10.1016/j.eats.2012.03.001",
  "pmid": "23766980",
  "abstract": "Adhesive capsulitis is a common and challenging condition to treat. Arthroscopic capsular release is usually contemplated when conservative treatment fails or when there is severe and/or chronic loss of range of motion. This procedure can be difficult to perform because of difficult access to the joint, poor visualization, and loss of working space from retraction of the joint capsule. The articular surfaces and the axillary nerve are also at higher risk of injury. Arthroscopic scissors, shavers, and electrocautery are typically used to perform the capsular release. To perform a safer and more precise arthroscopic shoulder capsular release, a creative and innovative use of a flexible hip arthroscopy radiofrequency ablator is described.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "other",
    "studyTypeLabel": "Other",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "RF",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "The article describes an innovative technique using a flexible hip arthroscopy radiofrequency ablator to perform arthroscopic shoulder capsular release, aiming for a safer and more precise procedure.",
    "outcomes": [
      "Procedural technique for arthroscopic shoulder capsular release (frozen shoulder/adhesive capsulitis)",
      "Safety/precision of capsular release (descriptive)"
    ],
    "limitations": [
      "No study design",
      "quantitative results",
      "or comparative data are provided in the abstract",
      "No exposure parameters (e.g.",
      "frequency",
      "power",
      "duration) are reported",
      "Population and sample size are not stated"
    ],
    "keywords": [
      "adhesive capsulitis",
      "frozen shoulder",
      "arthroscopic capsular release",
      "radiofrequency ablator",
      "arthroscopy technique",
      "surgical device"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"other\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"medical radiofrequency ablator (arthroscopy device)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Procedural technique for arthroscopic shoulder capsular release (frozen shoulder/adhesive capsulitis)\",\n    \"Safety/precision of capsular release (descriptive)\"\n  ],\n  \"main_findings\": \"The article describes an innovative technique using a flexible hip arthroscopy radiofrequency ablator to perform arthroscopic shoulder capsular release, aiming for a safer and more precise procedure.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No study design, quantitative results, or comparative data are provided in the abstract\",\n    \"No exposure parameters (e.g., frequency, power, duration) are reported\",\n    \"Population and sample size are not stated\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"adhesive capsulitis\",\n    \"frozen shoulder\",\n    \"arthroscopic capsular release\",\n    \"radiofrequency ablator\",\n    \"arthroscopy technique\",\n    \"surgical device\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/23766980/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3138",
  "updated": "2026-02-13 07:10:14"
}