  "id": 3171,
  "url": "https://nnemf.org/research/3171-development-of-a-prototype-of-the-tele-localisation",
  "title": "Development of a prototype of the tele-localisation system in radiotherapy using personal digital assistant via wireless communication.",
  "authors": [
    "Vincent Wing-Cheung Wu",
    "Fuk-hay Tang",
    "Wai-kwan Cheung",
    "Kit-chi Chan"
  ],
  "journal": "Journal of medical imaging and radiation oncology",
  "year": "2013",
  "doi": "10.1111/1754-9485.12016",
  "pmid": "23374563",
  "abstract": "In localisation of radiotherapy treatment field, the oncologist is present at the simulator to approve treatment details produced by the therapist. Problems may arise if the oncologist is not available and the patient requires urgent treatment. The development of a tele-localisation system is a potential solution, where the oncologist uses a personal digital assistant (PDA) to localise the treatment field on the image sent from the simulator through wireless communication and returns the information to the therapist after his or her approval. Our team developed the first tele-localisation prototype, which consisted of a server workstation (simulator) for the administration of digital imaging and communication in medicine localisation images including viewing and communication with the PDA via a Wi-Fi network; a PDA (oncologist's site) installed with the custom-built programme that synchronises with the server workstation and performs treatment field editing. Trial tests on accuracy and speed of the prototype system were conducted on 30 subjects with the treatment regions covering the neck, skull, chest and pelvis. The average time required in performing the localisation using the PDA was less than 1.5 min, with the blocked field longer than the open field. The transmission speed of the four treatment regions was similar. The average physical distortion of the images was within 4.4% and the accuracy of field size indication was within 5.3%. Compared with the manual method, the tele-localisation system presented with an average deviation of 5.5%. The prototype system fulfilled the planned objectives of tele-localisation procedure with reasonable speed and accuracy.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "30",
    "exposure": "RF 100–3000 MHz",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "A tele-localisation prototype using a PDA connected to a server workstation via a Wi-Fi network was tested on 30 subjects across neck, skull, chest, and pelvis regions. Average localisation time using the PDA was under 1.5 minutes; average image physical distortion was within 4.4%, field size indication accuracy within 5.3%, and average deviation versus the manual method was 5.5%.",
    "outcomes": [
      "Localisation time using PDA",
      "Transmission speed",
      "Image physical distortion",
      "Accuracy of field size indication",
      "Deviation vs manual method"
    ],
    "limitations": [
      "No health outcomes assessed",
      "study focuses on technical performance (speed/accuracy).",
      "Wi-Fi exposure parameters (e.g.",
      "frequency",
      "power",
      "SAR",
      "duration) not reported.",
      "Population characteristics and selection criteria not described in the abstract."
    ],
    "keywords": [
      "tele-localisation",
      "radiotherapy",
      "personal digital assistant",
      "PDA",
      "wireless communication",
      "Wi-Fi",
      "DICOM",
      "treatment field localisation",
      "prototype",
      "accuracy",
      "speed"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"wi-fi\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": 30,\n  \"outcomes\": [\n    \"Localisation time using PDA\",\n    \"Transmission speed\",\n    \"Image physical distortion\",\n    \"Accuracy of field size indication\",\n    \"Deviation vs manual method\"\n  ],\n  \"main_findings\": \"A tele-localisation prototype using a PDA connected to a server workstation via a Wi-Fi network was tested on 30 subjects across neck, skull, chest, and pelvis regions. Average localisation time using the PDA was under 1.5 minutes; average image physical distortion was within 4.4%, field size indication accuracy within 5.3%, and average deviation versus the manual method was 5.5%.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No health outcomes assessed; study focuses on technical performance (speed/accuracy).\",\n    \"Wi-Fi exposure parameters (e.g., frequency, power, SAR, duration) not reported.\",\n    \"Population characteristics and selection criteria not described in the abstract.\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"tele-localisation\",\n    \"radiotherapy\",\n    \"personal digital assistant\",\n    \"PDA\",\n    \"wireless communication\",\n    \"Wi-Fi\",\n    \"DICOM\",\n    \"treatment field localisation\",\n    \"prototype\",\n    \"accuracy\",\n    \"speed\"\n  ],\n  \"suggested_hubs\": []\n}"
  },