  "title": "[Realization of mobile phone based wireless blood pressure monitoring system and its preliminary implementation].",
  "authors": [
    "Shuo Wang",
    "Eenhao Gong",
    "Yang Yu",
    "Jing Liu"
  ],
  "journal": "Zhongguo yi liao qi xie za zhi = Chinese journal of medical instrumentation",
  "year": "2011",
  "doi": null,
  "pmid": "22379764",
  "abstract": "A novel system which could measure blood pressure wirelessly through mobile phone has been proposed and developed. It consisted of a blood pressure signal recorder based on MCU (Micro Control Unit), which could transmit measured data via Bluetooth, and a software embedded on mobile phone, which could calculate the value of blood pressure and the rate of heart beat. The measurement results could easily be stored in text documents or in picture format. Detailed scheme and design of each module in the system was illustrated and experiments were conducted to demonstrate the reliability and stability of the device. A series of new conceptual explorations into blood pressure related issues were conducted with this system, including the variational blood pressure at different time periods in a day, the effect of posture on the measurement results and the impact of movements on blood pressure.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "RF 100–3000 MHz",
    "confidencePct": "66",
    "peerReviewed": "yes",
    "mainFindings": "A mobile phone–based wireless blood pressure monitoring system using Bluetooth transmission was developed. Experiments were conducted to demonstrate the device's reliability and stability, and the system was used to explore variations in blood pressure by time of day, posture, and movement.",
    "outcomes": [
      "blood pressure measurement (wireless)",
      "heart beat rate calculation",
      "device reliability and stability"
    ],
    "limitations": [
      "No sample size or participant characteristics reported in the abstract.",
      "No quantitative performance metrics or statistical results provided in the abstract.",
      "Exposure parameters (e.g.",
      "frequency",
      "power",
      "SAR) not described."
    ],
    "keywords": [
      "mobile phone",
      "wireless",
      "Bluetooth",
      "blood pressure monitoring",
      "MCU",
      "heart rate",
      "device design",
      "reliability",
      "stability"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"mobile phone\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"blood pressure measurement (wireless)\",\n    \"heart beat rate calculation\",\n    \"device reliability and stability\"\n  ],\n  \"main_findings\": \"A mobile phone–based wireless blood pressure monitoring system using Bluetooth transmission was developed. Experiments were conducted to demonstrate the device's reliability and stability, and the system was used to explore variations in blood pressure by time of day, posture, and movement.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No sample size or participant characteristics reported in the abstract.\",\n    \"No quantitative performance metrics or statistical results provided in the abstract.\",\n    \"Exposure parameters (e.g., frequency, power, SAR) not described.\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.66,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"mobile phone\",\n    \"wireless\",\n    \"Bluetooth\",\n    \"blood pressure monitoring\",\n    \"MCU\",\n    \"heart rate\",\n    \"device design\",\n    \"reliability\",\n    \"stability\"\n  ],\n  \"suggested_hubs\": []\n}"
  },