Influence of magnetic field on aqueous two-phase extraction of horse ferritin in the polyethylene glycol/hydroxyethyl starch system.

Magdalena Zielińska-Dawidziak, Roman Błaszak, Dorota Piasecka-Kwiatkowska

PAPERpubmedAnalytica chimica acta2012OtherEffect: benefitEvidence: Low

Abstract

The presented experiments show the model of expectation of equine spleen ferritin extraction in a new aqueous two-phase system which was formed by mixing polyethylene glycol (PEG) and hydroxyethyl starch (HES). The tendency of the protein to migrate in the analyzed systems was dependent on the concentrations of HES and PEG as well as PEG molecular weight. The highest concentration of ferritin in the top phase (rich in PEG) was recorded in the system composed of 6% PEG 3000 and 3% HES. The obtained concentration was 0.88 mg mL(-1). The lowest concentration was 0.42 mg mL(-1) in the system composed of 5% PEG 6000 and 1% HES. Next the influence of the magnetic field on ferritin accumulation was analyzed. Selected samples were placed between homogeneous (S/S) or heterogeneous magnetic poles (N/S and S/N). It was observed that after the application of the magnetic field the extraction of ferritin into the PEG rich phase increased in every examined system. That increase was as high as 1.67-fold ferritin concentration in the PEG phase as compared with the total concentration of ferritin in the system before separation. Introduction of the magnetic field to two-phase extraction systems is shown as an effective method of changing the partition coefficient of ferritin.

AI evidence extraction

At a glance
Study type
Other
Effect direction
benefit
Population
—
Sample size
—
Exposure
magnetic field applied during aqueous two-phase extraction (homogeneous or heterogeneous magnetic poles)
Evidence strength
Low
Confidence: 74% · Peer-reviewed: yes

Main findings

Ferritin migration depended on PEG and HES concentrations and PEG molecular weight, with the highest ferritin concentration in the PEG-rich phase reported for 6% PEG 3000 and 3% HES (0.88 mg/mL) and the lowest for 5% PEG 6000 and 1% HES (0.42 mg/mL). When selected samples were placed between homogeneous (S/S) or heterogeneous (N/S, S/N) magnetic poles, ferritin extraction into the PEG-rich phase increased in every examined system, with increases reported up to 1.67-fold compared with the total ferritin concentration before separation.

Outcomes measured

  • Ferritin concentration in PEG-rich (top) phase
  • Ferritin partitioning/partition coefficient in PEG/HES aqueous two-phase system

Limitations

  • Magnetic field characteristics (e.g.
  • field strength
  • frequency/time variation) not reported in the abstract
  • No sample size/replication details provided in the abstract
  • In vitro/analytical system
  • not a health outcome study
View raw extracted JSON
{
  "study_type": "other",
  "exposure": {
    "band": null,
    "source": "magnetic field applied during aqueous two-phase extraction (homogeneous or heterogeneous magnetic poles)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "Ferritin concentration in PEG-rich (top) phase",
    "Ferritin partitioning/partition coefficient in PEG/HES aqueous two-phase system"
  ],
  "main_findings": "Ferritin migration depended on PEG and HES concentrations and PEG molecular weight, with the highest ferritin concentration in the PEG-rich phase reported for 6% PEG 3000 and 3% HES (0.88 mg/mL) and the lowest for 5% PEG 6000 and 1% HES (0.42 mg/mL). When selected samples were placed between homogeneous (S/S) or heterogeneous (N/S, S/N) magnetic poles, ferritin extraction into the PEG-rich phase increased in every examined system, with increases reported up to 1.67-fold compared with the total ferritin concentration before separation.",
  "effect_direction": "benefit",
  "limitations": [
    "Magnetic field characteristics (e.g., field strength, frequency/time variation) not reported in the abstract",
    "No sample size/replication details provided in the abstract",
    "In vitro/analytical system; not a health outcome study"
  ],
  "evidence_strength": "low",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "magnetic field",
    "aqueous two-phase extraction",
    "polyethylene glycol",
    "hydroxyethyl starch",
    "ferritin",
    "partition coefficient"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 3256

Influence of magnetic field on aqueous two-phase extraction of horse ferritin in the polyethylene glycol/hydroxyethyl starch system. · Non-native EMF