Influence of pulsed electric field treatments on the volatile compounds of milk in comparison with pasteurized processing.
Abstract
Effects of pulsed electric field (PEF) treatments on the volatile profiles of milk were studied and compared with pasteurized treatment of high temperature short time (HTST) (75 °C, 15 s). Volatile compounds were extracted by solid-phase micro-extraction (SPME) and identified by gas chromatography/mass spectrometry (GC-MS) and gas chromatography-olfactometry (GC-O). A total of 37 volatile compounds were determined by GC-MS, and 19 volatile compounds were considered to be major contributors to the characteristic flavor of milk samples. PEF treatment resulted in an increase in aldehydes. Milk treated with PEF at 30 kV/cm showed the highest content of pentanal, hexanal, and nonanal, while heptanal and decanal contents were lower than in pasteurized milk, but higher than in raw milk. All the methyl ketones detected in PEF milk were lower than in pasteurized milk. No significant differences in acids (acetic acid, butanoic acid, hexanoic acid, octanoic acid, and decanoic acid), lactones, and alcohols were observed between pasteurized and PEF-treated samples; however, 2(5H)-furanone was only detected in PEF-treated milk. Although GC-MS results showed that there were some volatile differences between pasteurized and PEF-treated milk, GC-O data showed no significant difference between the 2 samples.
AI evidence extraction
Main findings
PEF-treated milk showed changes in volatile composition versus HTST pasteurized milk, including increased aldehydes and lower methyl ketones; some compounds (e.g., 2(5H)-furanone) were detected only in PEF-treated milk. Despite GC-MS differences, GC-olfactometry indicated no significant difference between pasteurized and PEF-treated samples.
Outcomes measured
- Milk volatile compound profile (GC-MS)
- Odor-active compounds / sensory-relevant volatiles (GC-O)
Limitations
- Sample size not reported in abstract
- PEF parameters incompletely reported (only field strength noted
- other settings/duration not stated)
- Outcomes limited to volatile profiles/GC-O
- broader health or safety outcomes not assessed
View raw extracted JSON
{
"study_type": "other",
"exposure": {
"band": null,
"source": "pulsed electric field (PEF) food processing",
"frequency_mhz": null,
"sar_wkg": null,
"duration": null
},
"population": null,
"sample_size": null,
"outcomes": [
"Milk volatile compound profile (GC-MS)",
"Odor-active compounds / sensory-relevant volatiles (GC-O)"
],
"main_findings": "PEF-treated milk showed changes in volatile composition versus HTST pasteurized milk, including increased aldehydes and lower methyl ketones; some compounds (e.g., 2(5H)-furanone) were detected only in PEF-treated milk. Despite GC-MS differences, GC-olfactometry indicated no significant difference between pasteurized and PEF-treated samples.",
"effect_direction": "mixed",
"limitations": [
"Sample size not reported in abstract",
"PEF parameters incompletely reported (only field strength noted; other settings/duration not stated)",
"Outcomes limited to volatile profiles/GC-O; broader health or safety outcomes not assessed"
],
"evidence_strength": "low",
"confidence": 0.74,
"peer_reviewed_likely": "yes",
"keywords": [
"pulsed electric field",
"PEF",
"milk",
"pasteurization",
"HTST",
"volatile compounds",
"SPME",
"GC-MS",
"GC-olfactometry",
"aldehydes",
"methyl ketones"
],
"suggested_hubs": []
}AI can be wrong. Always verify against the paper.
Comments
Log in to comment.
No comments yet.
NNEMF synthesis
Synthesis pending.