  "id": 3352,
  "url": "https://nnemf.org/research/3352-enhanced-detection-resonance-frequency-shift-of-a-piezoelectric",
  "title": "Enhanced Detection Resonance Frequency Shift of a Piezoelectric Microcantilever Sensor by a DC Bias Electric Field in Humidity Detection.",
  "authors": [
    "Qing Zhu",
    "Wan Y Shih",
    "Wei-Heng Shih"
  ],
  "journal": "Sensors and actuators. B, Chemical",
  "year": "2009",
  "doi": "10.1016/j.snb.2009.01.035",
  "pmid": "20161253",
  "abstract": "We have examined the relative longitudinal flexural resonance frequency shift of a PMN-PT/tin PEMS with a DC bias electric field, E, in humidity detection. We showed that the relative resonance frequency shift could be enhanced by applying an E to the PMN-PT layer during detection. A maximum enhancement of more than three times in resonance frequency shift was observed at E = -6 kV/cm as compared to the resonance frequency shift without a bias field. The maximal relative resonance frequency shift at E = -6 kV/cm was about 1000 times larger than could be accounted for by mass loading alone.",
  "effect": "benefit",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "benefit",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "DC bias electric field (applied to PMN-PT layer in a piezoelectric microcantilever sensor)",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Applying a DC bias electric field to the PMN-PT layer during humidity detection enhanced the relative longitudinal flexural resonance frequency shift of the PMN-PT/tin PEMS. The maximum enhancement was reported as more than threefold at E = -6 kV/cm compared with no bias field, and the maximal shift at this field was about 1000 times larger than could be explained by mass loading alone.",
    "outcomes": [
      "Longitudinal flexural resonance frequency shift (relative)",
      "Humidity detection sensitivity/enhancement"
    ],
    "limitations": [
      "No sample size or number of devices/replicates reported in the abstract",
      "No details on humidity range",
      "experimental conditions",
      "or statistical analysis provided in the abstract",
      "Mechanistic attribution beyond mass loading is not fully detailed in the abstract"
    ],
    "keywords": [
      "piezoelectric microcantilever sensor",
      "PMN-PT",
      "PEMS",
      "DC bias electric field",
      "humidity detection",
      "resonance frequency shift",
      "mass loading"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"DC bias electric field (applied to PMN-PT layer in a piezoelectric microcantilever sensor)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Longitudinal flexural resonance frequency shift (relative)\",\n    \"Humidity detection sensitivity/enhancement\"\n  ],\n  \"main_findings\": \"Applying a DC bias electric field to the PMN-PT layer during humidity detection enhanced the relative longitudinal flexural resonance frequency shift of the PMN-PT/tin PEMS. The maximum enhancement was reported as more than threefold at E = -6 kV/cm compared with no bias field, and the maximal shift at this field was about 1000 times larger than could be explained by mass loading alone.\",\n  \"effect_direction\": \"benefit\",\n  \"limitations\": [\n    \"No sample size or number of devices/replicates reported in the abstract\",\n    \"No details on humidity range, experimental conditions, or statistical analysis provided in the abstract\",\n    \"Mechanistic attribution beyond mass loading is not fully detailed in the abstract\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"piezoelectric microcantilever sensor\",\n    \"PMN-PT\",\n    \"PEMS\",\n    \"DC bias electric field\",\n    \"humidity detection\",\n    \"resonance frequency shift\",\n    \"mass loading\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/20161253/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3352",
  "updated": "2026-02-13 07:19:34"
}