{
  "id": 3385,
  "url": "https://nnemf.org/research/3385-position-independent-chemical-quantitation-with-passive-13-56",
  "title": "Position-independent chemical quantitation with passive 13.56-MHz radio frequency identification (RFID) sensors.",
  "authors": [
    "Radislav A Potyrailo",
    "Henri Mouquin",
    "William G Morris"
  ],
  "journal": "Talanta",
  "year": "2008",
  "doi": "10.1016/j.talanta.2007.06.023",
  "pmid": "18585123",
  "abstract": "Recently, we have demonstrated an attractive approach to adapt conventional radio frequency identification (RFID) tags for multianalyte chemical sensing. These RFID sensors could be very attractive as ubiquitous distributed remote sensor networks. However, critical to the wide acceptance of the demonstrated RFID sensors is the analyte-quantitation ability of these sensors in presence of possible repositioning errors between the RFID sensor and its pickup coil. In this study, we evaluate the capability for such position-independent analyte quantification using multivariate analysis tools. By measuring simultaneously several parameters of the complex impedance from such an RFID sensor and applying multivariate statistical analysis methods, we were able to compensate for the repositioning effects such as baseline signal offset and magnitude of sensor response to an analyte.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "RF RFID sensor · 13.56 MHz",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "The study evaluated position-independent analyte quantification for passive 13.56-MHz RFID chemical sensors. Simultaneous measurement of multiple complex-impedance parameters combined with multivariate statistical analysis was able to compensate for repositioning effects such as baseline signal offset and changes in response magnitude.",
    "outcomes": [
      "Position-independent analyte quantification",
      "Compensation for repositioning effects (baseline signal offset",
      "magnitude of sensor response) using multivariate analysis of complex impedance parameters"
    ],
    "limitations": [],
    "keywords": [
      "RFID",
      "13.56 MHz",
      "chemical sensing",
      "analyte quantification",
      "complex impedance",
      "multivariate analysis",
      "repositioning error",
      "pickup coil"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"RFID sensor\",\n    \"frequency_mhz\": 13.56,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Position-independent analyte quantification\",\n    \"Compensation for repositioning effects (baseline signal offset, magnitude of sensor response) using multivariate analysis of complex impedance parameters\"\n  ],\n  \"main_findings\": \"The study evaluated position-independent analyte quantification for passive 13.56-MHz RFID chemical sensors. Simultaneous measurement of multiple complex-impedance parameters combined with multivariate statistical analysis was able to compensate for repositioning effects such as baseline signal offset and changes in response magnitude.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"RFID\",\n    \"13.56 MHz\",\n    \"chemical sensing\",\n    \"analyte quantification\",\n    \"complex impedance\",\n    \"multivariate analysis\",\n    \"repositioning error\",\n    \"pickup coil\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/18585123/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3385",
  "updated": "2026-02-13 07:21:45"
}