{
  "id": 3399,
  "url": "https://nnemf.org/research/3399-evaluation-of-the-genotoxicity-of-the-extremely-low",
  "title": "[Evaluation of the genotoxicity of the extremely low frequency-magnetic fields (ELF-MF) in workers exposed for professional reasons].",
  "authors": [
    "M Scaringi",
    "P Temperani",
    "P Rossi",
    "G Bravo",
    "F Gobba"
  ],
  "journal": "Giornale italiano di medicina del lavoro ed ergonomia",
  "year": "2007",
  "doi": null,
  "pmid": "18409756",
  "abstract": "Whether or not ELF-MF has genotoxic potential is a controversial issue. In the present study, we investigated the genotoxic effect using cytogenetic assays (CA - SCE - MN), in 109 workers exposed to ELF-MF. The mean value of occupational exposure in the whole group was 0.35 microT. According to the exposure level the workers were stratified in two different groups: low exposed (n. 39, TWA < or = 0.2 microT) and higher exposed (n. 70; TWA > 0.2 microT): the groups did not significantly differ for the examined variables. Due to these results we decided to re-evaluate the effect only considering the highest exposed workers: we selected 31 workers exposed to TWA levels exceeding 1 microT, and compared vs. the low exposed subjects: again, the difference in the groups examined were not significant. At multivariate regression analysis was also applied: no correlation was observed with cytogenetic biomarkers. The results of this study does not support the hypothesis of any direct genotoxic effect of ELF-MF, at least at the environmental levels currently found in an occupational settings.",
  "effect": "no_effect",
  "evidence": "low",
  "extraction": {
    "studyType": "cohort",
    "studyTypeLabel": "cohort",
    "effectDirection": "no_effect",
    "evidenceLabel": "Low",
    "population": "Workers occupationally exposed to extremely low frequency magnetic fields (ELF-MF)",
    "sampleSize": "109",
    "exposure": "ELF <1 MHz",
    "confidencePct": "78",
    "peerReviewed": "yes",
    "mainFindings": "In 109 workers (mean occupational exposure 0.35 microT), cytogenetic biomarkers (CA, SCE, MN) did not differ significantly between low-exposed (TWA ≤0.2 microT) and higher-exposed (TWA >0.2 microT) groups. A comparison of the highest-exposed subgroup (n=31; TWA >1 microT) versus low-exposed workers also found no significant differences, and multivariate regression showed no correlation between exposure and cytogenetic biomarkers.",
    "outcomes": [
      "Cytogenetic assays (CA)",
      "Sister chromatid exchange (SCE)",
      "Micronucleus test (MN)"
    ],
    "limitations": [
      "Frequency of ELF-MF not reported",
      "Exposure duration/time in job not reported",
      "Details of cytogenetic assay results (effect sizes/values) not provided in abstract",
      "Potential confounding control variables not specified beyond mention of multivariate regression"
    ],
    "keywords": [
      "ELF-MF",
      "extremely low frequency",
      "magnetic fields",
      "occupational exposure",
      "genotoxicity",
      "cytogenetics",
      "CA",
      "SCE",
      "micronucleus",
      "TWA",
      "microtesla"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "Study evaluates genotoxicity biomarkers in workers exposed to ELF magnetic fields at work."
      }
    ],
    "raw": "{\n  \"study_type\": \"cohort\",\n  \"exposure\": {\n    \"band\": \"ELF\",\n    \"source\": \"occupational\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"Workers occupationally exposed to extremely low frequency magnetic fields (ELF-MF)\",\n  \"sample_size\": 109,\n  \"outcomes\": [\n    \"Cytogenetic assays (CA)\",\n    \"Sister chromatid exchange (SCE)\",\n    \"Micronucleus test (MN)\"\n  ],\n  \"main_findings\": \"In 109 workers (mean occupational exposure 0.35 microT), cytogenetic biomarkers (CA, SCE, MN) did not differ significantly between low-exposed (TWA ≤0.2 microT) and higher-exposed (TWA >0.2 microT) groups. A comparison of the highest-exposed subgroup (n=31; TWA >1 microT) versus low-exposed workers also found no significant differences, and multivariate regression showed no correlation between exposure and cytogenetic biomarkers.\",\n  \"effect_direction\": \"no_effect\",\n  \"limitations\": [\n    \"Frequency of ELF-MF not reported\",\n    \"Exposure duration/time in job not reported\",\n    \"Details of cytogenetic assay results (effect sizes/values) not provided in abstract\",\n    \"Potential confounding control variables not specified beyond mention of multivariate regression\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.78,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"ELF-MF\",\n    \"extremely low frequency\",\n    \"magnetic fields\",\n    \"occupational exposure\",\n    \"genotoxicity\",\n    \"cytogenetics\",\n    \"CA\",\n    \"SCE\",\n    \"micronucleus\",\n    \"TWA\",\n    \"microtesla\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.95,\n      \"reason\": \"Study evaluates genotoxicity biomarkers in workers exposed to ELF magnetic fields at work.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/18409756/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3399",
  "updated": "2026-02-13 07:21:58"
}