{
  "id": 3433,
  "url": "https://nnemf.org/research/3433-development-of-a-patch-antenna-array-rf-coil",
  "title": "Development of a patch antenna array RF coil for ultra-high field MRI.",
  "authors": [
    "Manabu Nakajima",
    "Iwao Nakajima",
    "Shigeru Obayashi",
    "Yuji Nagai",
    "Takayuki Obata",
    "Yoshiyuki Hirano",
    "Hiroo Ikehira"
  ],
  "journal": "Magnetic resonance in medical sciences : MRMS : an official journal of Japan Society of Magnetic Resonance in Medicine",
  "year": "2007",
  "doi": "10.2463/mrms.6.231",
  "pmid": "18239360",
  "abstract": "In radiofrequency (RF) coil design for ultra-high-field magnetic resonance (MR) imaging, short RF wavelengths present various challenges to creating a big volume coil. When imaging a human body using an ultra-high magnetic field MR imaging system (magnetic flux density of 7 Tesla or more), short wavelength may induce artifacts from dielectric effect and other factors. To overcome these problems, we developed a patch antenna array coil (PAAC), which is a coil configured as a combination of patch antennas. We prototyped this type of coil for 7T proton MR imaging, imaged a monkey brain, and confirmed the coil's utility as an RF coil for ultra-high-field MR imaging.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "Monkey (brain imaging)",
    "sampleSize": "—",
    "exposure": "RF",
    "confidencePct": "66",
    "peerReviewed": "yes",
    "mainFindings": "The authors developed a patch antenna array coil (PAAC) for 7T proton MR imaging and used it to image a monkey brain, confirming its utility as an RF coil for ultra-high-field MR imaging.",
    "outcomes": [
      "RF coil design/performance for ultra-high-field MRI",
      "Imaging utility/feasibility (artifact reduction/coil utility)"
    ],
    "limitations": [
      "No quantitative performance metrics or comparisons are provided in the abstract.",
      "Sample size and experimental details (e.g.",
      "imaging parameters",
      "artifact measures) are not stated.",
      "No RF exposure metrics (e.g.",
      "frequency",
      "SAR) are reported in the abstract."
    ],
    "keywords": [
      "RF coil",
      "patch antenna array coil",
      "PAAC",
      "7T",
      "ultra-high-field MRI",
      "proton MR imaging",
      "dielectric effect",
      "artifacts",
      "monkey brain"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"MRI RF coil\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"Monkey (brain imaging)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"RF coil design/performance for ultra-high-field MRI\",\n    \"Imaging utility/feasibility (artifact reduction/coil utility)\"\n  ],\n  \"main_findings\": \"The authors developed a patch antenna array coil (PAAC) for 7T proton MR imaging and used it to image a monkey brain, confirming its utility as an RF coil for ultra-high-field MR imaging.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No quantitative performance metrics or comparisons are provided in the abstract.\",\n    \"Sample size and experimental details (e.g., imaging parameters, artifact measures) are not stated.\",\n    \"No RF exposure metrics (e.g., frequency, SAR) are reported in the abstract.\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.66,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"RF coil\",\n    \"patch antenna array coil\",\n    \"PAAC\",\n    \"7T\",\n    \"ultra-high-field MRI\",\n    \"proton MR imaging\",\n    \"dielectric effect\",\n    \"artifacts\",\n    \"monkey brain\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"mri-rf-coils\",\n      \"weight\": 0.9,\n      \"reason\": \"Engineering development of an RF coil (patch antenna array) for 7T MRI.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/18239360/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3433",
  "updated": "2026-02-13 07:22:23"
}