Magnetic field mapping by selective equipotential excitation.

Ouajdi Felfoul, Michelle Raimbert, Sylvain Martel

PAPERpubmedConference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference2006engineeringEffect: unclearEvidence: Insufficient

Abstract

A new magnetic field mapping method in MRI is presented. This technique is ideal for severe inhomogeneities where plane warp cannot be ignored. The present study employs a ferromagnetic ball to create a perturbation within the imaged volume. The magnetic moment and position of the device are acquired experimentally with a new technique that excites magnetic equipotentials within a volume. A three dimensional perturbation field is then reconstructed from which an accurate field map is acquired for any slice within the volume. This method is compared with phase imaging, which is commonly used to map the magnetic field perturbation. Preliminary investigations show that this method is accurate and provides field maps that do not suffer from distortion in the slice select and read direction. This method can help in the correction of susceptibility artifacts by providing an accurate map of the perturbing field generated by magnetic markers on medical instruments.

AI evidence extraction

At a glance
Study type
engineering
Effect direction
unclear
Population
โ€”
Sample size
โ€”
Exposure
MRI
Evidence strength
Insufficient
Confidence: 74% ยท Peer-reviewed: yes

Main findings

The study presents a magnetic field mapping method for MRI using selective excitation of magnetic equipotentials and a ferromagnetic ball to create a perturbation. Preliminary investigations indicate the method is accurate and yields field maps without distortion in the slice select and read directions, and it is compared against phase imaging.

Outcomes measured

  • Magnetic field mapping accuracy in MRI
  • Distortion in slice select and read directions
  • Correction of susceptibility artifacts
  • Reconstruction of 3D perturbation field from magnetic markers/ferromagnetic ball

Limitations

  • Only preliminary investigations are reported
  • No quantitative performance metrics or sample size are provided in the abstract
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": null,
    "source": "MRI",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "Magnetic field mapping accuracy in MRI",
    "Distortion in slice select and read directions",
    "Correction of susceptibility artifacts",
    "Reconstruction of 3D perturbation field from magnetic markers/ferromagnetic ball"
  ],
  "main_findings": "The study presents a magnetic field mapping method for MRI using selective excitation of magnetic equipotentials and a ferromagnetic ball to create a perturbation. Preliminary investigations indicate the method is accurate and yields field maps without distortion in the slice select and read directions, and it is compared against phase imaging.",
  "effect_direction": "unclear",
  "limitations": [
    "Only preliminary investigations are reported",
    "No quantitative performance metrics or sample size are provided in the abstract"
  ],
  "evidence_strength": "insufficient",
  "confidence": 0.74,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "MRI",
    "magnetic field mapping",
    "equipotential excitation",
    "ferromagnetic ball",
    "phase imaging",
    "susceptibility artifacts",
    "magnetic markers",
    "medical instruments"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 3463

Magnetic field mapping by selective equipotential excitation. ยท Non-native EMF