{
  "id": 3481,
  "url": "https://nnemf.org/research/3481-numerical-evaluation-of-radio-frequency-power-deposition-in",
  "title": "Numerical evaluation of radio frequency power deposition in human models during MRI.",
  "authors": [
    "M A Stuchly",
    "H Abrishamkar",
    "M L Strydom"
  ],
  "journal": "Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference",
  "year": "2006",
  "doi": "10.1109/iembs.2006.259880",
  "pmid": "17945576",
  "abstract": "Concerns have been expressed about safety of MRI examination of two groups of people, namely pregnant mothers and cardiac pacemaker bearers. The main uncertainty relates to excessive heating by pulsed radio frequency (RF) fields. To address these issues, numerical evaluations of the power deposition are performed for a 27-week old fetus in a simplified model of the mother, and a realistic model of a human torso with an in situ pacemaker including its leads. The evaluations are supplemented with organ dosimetry for a realistic model of the human torso. An ideal non-resonant and two resonant birdcage coils operating at 64 MHz (corresponding to 1.5 T MRI) are evaluated. All simulations are performed with the finite difference time domain (FDTD) method.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "Pregnant mothers (27-week fetus model) and cardiac pacemaker bearers (human torso model with in situ pacemaker and leads)",
    "sampleSize": "—",
    "exposure": "RF MRI · 64 MHz",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Numerical simulations evaluated RF power deposition for a 27-week fetus in a simplified maternal model and for a realistic human torso model with an in situ pacemaker and leads, with additional organ dosimetry for a realistic torso model. Simulations assessed an ideal non-resonant and two resonant birdcage coils operating at 64 MHz (1.5 T MRI) using the FDTD method.",
    "outcomes": [
      "Numerical evaluation of RF power deposition",
      "Organ dosimetry",
      "Excessive heating concern (context)"
    ],
    "limitations": [
      "No quantitative results (e.g.",
      "SAR",
      "temperature rise) reported in the abstract",
      "Model-based numerical evaluation",
      "real-world exposure conditions and validation not described in the abstract",
      "Sample size not applicable/unspecified"
    ],
    "keywords": [
      "MRI",
      "radio frequency",
      "power deposition",
      "heating",
      "pregnancy",
      "fetus",
      "pacemaker",
      "birdcage coil",
      "64 MHz",
      "1.5 T",
      "FDTD",
      "organ dosimetry"
    ],
    "hubs": [
      {
        "slug": "occupational-exposure",
        "weight": "0.7",
        "reason": "MRI-related RF exposure assessment may be relevant to clinical/technical settings, but the abstract focuses on patients rather than workers."
      }
    ],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"MRI\",\n    \"frequency_mhz\": 64,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"Pregnant mothers (27-week fetus model) and cardiac pacemaker bearers (human torso model with in situ pacemaker and leads)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Numerical evaluation of RF power deposition\",\n    \"Organ dosimetry\",\n    \"Excessive heating concern (context)\"\n  ],\n  \"main_findings\": \"Numerical simulations evaluated RF power deposition for a 27-week fetus in a simplified maternal model and for a realistic human torso model with an in situ pacemaker and leads, with additional organ dosimetry for a realistic torso model. Simulations assessed an ideal non-resonant and two resonant birdcage coils operating at 64 MHz (1.5 T MRI) using the FDTD method.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"No quantitative results (e.g., SAR, temperature rise) reported in the abstract\",\n    \"Model-based numerical evaluation; real-world exposure conditions and validation not described in the abstract\",\n    \"Sample size not applicable/unspecified\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"MRI\",\n    \"radio frequency\",\n    \"power deposition\",\n    \"heating\",\n    \"pregnancy\",\n    \"fetus\",\n    \"pacemaker\",\n    \"birdcage coil\",\n    \"64 MHz\",\n    \"1.5 T\",\n    \"FDTD\",\n    \"organ dosimetry\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"occupational-exposure\",\n      \"weight\": 0.2,\n      \"reason\": \"MRI-related RF exposure assessment may be relevant to clinical/technical settings, but the abstract focuses on patients rather than workers.\"\n    }\n  ]\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/17945576/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3481",
  "updated": "2026-02-13 07:23:51"
}