  "id": 3489,
  "url": "https://nnemf.org/research/3489-determination-of-blood-longitudinal-relaxation-time-t1-at",
  "title": "Determination of blood longitudinal relaxation time (T1) at high magnetic field strengths.",
  "authors": [
    "Mircea C Dobre",
    "Kâmil Uğurbil",
    "Malgorzata Marjanska"
  ],
  "journal": "Magnetic resonance imaging",
  "year": "2007",
  "doi": "10.1016/j.mri.2006.10.020",
  "pmid": "17540286",
  "abstract": "In this study, a circulation system was used to measure T(1) values of bovine blood under physiological conditions at field strengths of 4.7, 7 and 9.4 T. Results show that T(1) increases linearly with magnetic field B(0) and can be described with the equation T(1)=129 ms/T B(0)+1167 ms for magnetic field strengths between 1.5 and 9.4 T.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "other",
    "studyTypeLabel": "Other",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "Bovine blood (circulating system)",
    "sampleSize": "—",
    "exposure": "MRI (static magnetic field B0)",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "Using a circulation system under physiological conditions, bovine blood T1 increased linearly with magnetic field strength (B0) across 4.7, 7, and 9.4 T. The relationship was described as T1 = 129 ms/T * B0 + 1167 ms for magnetic field strengths between 1.5 and 9.4 T.",
    "outcomes": [
      "Blood longitudinal relaxation time (T1)"
    ],
    "limitations": [
      "Sample size not reported in abstract",
      "Study uses bovine blood in a circulation system",
      "generalizability to humans not stated",
      "No health outcomes assessed",
      "outcome is a measurement parameter (T1)"
    ],
    "keywords": [
      "MRI",
      "static magnetic field",
      "B0",
      "T1 relaxation time",
      "blood",
      "high field strength",
      "4.7 T",
      "7 T",
      "9.4 T"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"other\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": \"MRI (static magnetic field B0)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": \"Bovine blood (circulating system)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Blood longitudinal relaxation time (T1)\"\n  ],\n  \"main_findings\": \"Using a circulation system under physiological conditions, bovine blood T1 increased linearly with magnetic field strength (B0) across 4.7, 7, and 9.4 T. The relationship was described as T1 = 129 ms/T * B0 + 1167 ms for magnetic field strengths between 1.5 and 9.4 T.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [\n    \"Sample size not reported in abstract\",\n    \"Study uses bovine blood in a circulation system; generalizability to humans not stated\",\n    \"No health outcomes assessed; outcome is a measurement parameter (T1)\"\n  ],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"MRI\",\n    \"static magnetic field\",\n    \"B0\",\n    \"T1 relaxation time\",\n    \"blood\",\n    \"high field strength\",\n    \"4.7 T\",\n    \"7 T\",\n    \"9.4 T\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/17540286/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3489",
  "updated": "2026-02-13 07:23:56"
}