  "title": "Recovery of small-sized blood vessels in ischemic bone under static magnetic field.",
  "authors": [
    "Shenzhi Xu",
    "Naohide Tomita",
    "Ken Ikeuchi",
    "Yoshito Ikada"
  ],
  "journal": "Evidence-based complementary and alternative medicine : eCAM",
  "year": "2007",
  "doi": "10.1093/ecam/nel055",
  "pmid": "17342242",
  "abstract": "Effects of static magnetic field (SMF) on the vascularization in bone were evaluated using an ischemic bone model, where rat femoral artery was ligated. Magnetized and unmagnetized samarium-cobalt rods were implanted transcortically into the middle diaphysis of the ischemic femurs. Collateral circulation was evaluated by injection of microspheres into the abdominal aorta at the third week after ligation. It was found that the bone implanted with a magnetized rod showed a larger amount of trapped microspheres than that with an unmagnetized rod at the proximal and the distal region (P < 0.05 proximal region). There were no significant differences at the middle and the distal region. This tendency was similar to that of the bone mineral density in the SMF-exposed ischemic bone.",
  "effect": "mixed",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "mixed",
    "evidenceLabel": "Low",
    "population": "Rats with ischemic femur (femoral artery ligation model)",
    "sampleSize": "—",
    "exposure": "static implanted magnetized samarium-cobalt rod · 3 weeks after femoral artery ligation (assessment timepoint)",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "In an ischemic rat femur model, bones implanted with a magnetized samarium-cobalt rod showed a larger amount of trapped microspheres than bones with an unmagnetized rod in proximal and distal regions (reported as significant in the proximal region, P<0.05). No significant differences were observed at the middle and distal regions. A similar tendency was reported for bone mineral density in SMF-exposed ischemic bone.",
    "outcomes": [
      "Collateral circulation in ischemic bone (microsphere trapping)",
      "Bone mineral density"
    ],
    "limitations": [
      "Sample size not reported in abstract",
      "Static magnetic field strength/exposure level not reported",
      "Significance reporting appears inconsistent across regions (e.g.",
      "distal described as larger but also described as not significantly different)",
      "Animal ischemic bone model",
      "generalizability to humans not addressed in abstract"
    ],
    "keywords": [
      "static magnetic field",
      "ischemic bone",
      "rat model",
      "femoral artery ligation",
      "samarium-cobalt magnet",
      "vascularization",
      "collateral circulation",
      "microspheres",
      "bone mineral density"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"static\",\n    \"source\": \"implanted magnetized samarium-cobalt rod\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"3 weeks after femoral artery ligation (assessment timepoint)\"\n  },\n  \"population\": \"Rats with ischemic femur (femoral artery ligation model)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Collateral circulation in ischemic bone (microsphere trapping)\",\n    \"Bone mineral density\"\n  ],\n  \"main_findings\": \"In an ischemic rat femur model, bones implanted with a magnetized samarium-cobalt rod showed a larger amount of trapped microspheres than bones with an unmagnetized rod in proximal and distal regions (reported as significant in the proximal region, P<0.05). No significant differences were observed at the middle and distal regions. A similar tendency was reported for bone mineral density in SMF-exposed ischemic bone.\",\n  \"effect_direction\": \"mixed\",\n  \"limitations\": [\n    \"Sample size not reported in abstract\",\n    \"Static magnetic field strength/exposure level not reported\",\n    \"Significance reporting appears inconsistent across regions (e.g., distal described as larger but also described as not significantly different)\",\n    \"Animal ischemic bone model; generalizability to humans not addressed in abstract\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"static magnetic field\",\n    \"ischemic bone\",\n    \"rat model\",\n    \"femoral artery ligation\",\n    \"samarium-cobalt magnet\",\n    \"vascularization\",\n    \"collateral circulation\",\n    \"microspheres\",\n    \"bone mineral density\"\n  ],\n  \"suggested_hubs\": [\n    {\n      \"slug\": \"animal-studies\",\n      \"weight\": 0.9,\n      \"reason\": \"Rat ischemic bone model evaluating effects of static magnetic field exposure.\"\n    }\n  ]\n}"
  },