  "title": "Effects of monopolar radiofrequency heating on intradiscal pressure in sheep.",
  "authors": [
    "Ronald J Podhajsky",
    "Anna Belous",
    "Kristin Johnson",
    "Donald H Maul",
    "Philip M Finch"
  ],
  "journal": "The spine journal : official journal of the North American Spine Society",
  "year": "2007",
  "doi": "10.1016/j.spinee.2006.04.019",
  "pmid": "17321974",
  "abstract": "BACKGROUND CONTEXT: No previous study has assessed the effect of monopolar radiofrequency (RF) heating on intradiscal pressure. PURPOSE: To determine the decrease in lumbar intradiscal pressure after monopolar RF heating. STUDY DESIGN/SETTING: Intradiscal pressure was measured in sheep lumbar discs treated with monopolar RF heating. METHODS: Two monopolar RF heat treatments at 90 degrees C were applied for 2 minutes each to lumbar intervertebral discs of sheep. Intradiscal pressure was measured in live sheep at 0, 7, 14, 21, and 28 days posttreatment. Pressure measurements were taken with a microtip pressure transducer. Electrodes were inserted but not activated in separate discs as a sham control. In vitro sheep spine of different age groups, loading conditions, and electrode orientations were similarly heat treated and intradiscal pressures were measured. RESULTS: Intradiscal pressure was significantly reduced 1 week after monopolar RF heating and remained stable through the 4-week observation period. The RF electrode orientation, the age, and the type of disc loading have significant effects on the amount of initial intradiscal pressure reduction. CONCLUSIONS: Monopolar RF heating can reduce intradiscal pressure in the lumbar spine of sheep.",
  "effect": "benefit",
  "evidence": "low",
  "extraction": {
    "studyType": "animal",
    "studyTypeLabel": "Animal study",
    "effectDirection": "benefit",
    "evidenceLabel": "Low",
    "population": "Sheep (lumbar intervertebral discs; in vivo and in vitro sheep spine)",
    "sampleSize": "—",
    "exposure": "RF medical/therapeutic radiofrequency heating (monopolar RF) · Two treatments at 90°C for 2 minutes each",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "In live sheep, intradiscal pressure was significantly reduced 1 week after monopolar RF heating and remained stable through 4 weeks. In vitro experiments indicated that electrode orientation, age group, and disc loading type significantly affected the magnitude of the initial pressure reduction.",
    "outcomes": [
      "Lumbar intradiscal pressure (measured at 0",
      "7",
      "14",
      "21",
      "and 28 days posttreatment)"
    ],
    "limitations": [
      "Sample size not reported in abstract",
      "RF exposure parameters (e.g.",
      "frequency",
      "power",
      "SAR) not reported",
      "Animal model (sheep) and in vitro components may limit generalizability to humans",
      "Follow-up limited to 4 weeks in vivo"
    ],
    "keywords": [
      "radiofrequency heating",
      "monopolar RF",
      "intradiscal pressure",
      "lumbar disc",
      "sheep",
      "sham control",
      "in vivo",
      "in vitro"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"animal\",\n  \"exposure\": {\n    \"band\": \"RF\",\n    \"source\": \"medical/therapeutic radiofrequency heating (monopolar RF)\",\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": \"Two treatments at 90°C for 2 minutes each\"\n  },\n  \"population\": \"Sheep (lumbar intervertebral discs; in vivo and in vitro sheep spine)\",\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Lumbar intradiscal pressure (measured at 0, 7, 14, 21, and 28 days posttreatment)\"\n  ],\n  \"main_findings\": \"In live sheep, intradiscal pressure was significantly reduced 1 week after monopolar RF heating and remained stable through 4 weeks. In vitro experiments indicated that electrode orientation, age group, and disc loading type significantly affected the magnitude of the initial pressure reduction.\",\n  \"effect_direction\": \"benefit\",\n  \"limitations\": [\n    \"Sample size not reported in abstract\",\n    \"RF exposure parameters (e.g., frequency, power, SAR) not reported\",\n    \"Animal model (sheep) and in vitro components may limit generalizability to humans\",\n    \"Follow-up limited to 4 weeks in vivo\"\n  ],\n  \"evidence_strength\": \"low\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"radiofrequency heating\",\n    \"monopolar RF\",\n    \"intradiscal pressure\",\n    \"lumbar disc\",\n    \"sheep\",\n    \"sham control\",\n    \"in vivo\",\n    \"in vitro\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/17321974/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3514",
  "updated": "2026-02-13 07:24:12"
}