{
  "id": 3531,
  "url": "https://nnemf.org/research/3531-measurement-of-bioelectric-currents-based-on-the-coupling",
  "title": "Measurement of bioelectric currents based on the coupling of electric and magnetic field.",
  "authors": [
    "Zhang Hongmiao",
    "Liu Jun",
    "Yang Shaohua",
    "Lou Zhengguo",
    "Li Guang"
  ],
  "journal": "Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference",
  "year": "2005",
  "doi": "10.1109/iembs.2005.1617105",
  "pmid": "17282874",
  "abstract": "A method based on magneto-acoustic technique is developed to measure bioelectric currents non-invasively. Theoretically, vibrations of particles in the medium are produced due to the Lorentz force when oscillatory currents flow through medium in a steady magnetic field. These vibrations contain information of the bioelectric currents and can be detected by surface contact detector. An experimental setup is presented to detect the microampere level currents in saline and tissue. The results show the linear relationship between the acoustic signal and the current.",
  "effect": "unclear",
  "evidence": "insufficient",
  "extraction": {
    "studyType": "engineering",
    "studyTypeLabel": "engineering",
    "effectDirection": "unclear",
    "evidenceLabel": "Insufficient",
    "population": "—",
    "sampleSize": "—",
    "exposure": "",
    "confidencePct": "74",
    "peerReviewed": "yes",
    "mainFindings": "A magneto-acoustic method is described for non-invasive measurement of bioelectric currents, based on Lorentz-force-induced vibrations in a steady magnetic field. An experimental setup detected microampere-level currents in saline and tissue, and results showed a linear relationship between acoustic signal and current.",
    "outcomes": [
      "Non-invasive measurement/detection of bioelectric currents using magneto-acoustic technique",
      "Linear relationship between acoustic signal and current",
      "Detection of microampere-level currents in saline and tissue"
    ],
    "limitations": [],
    "keywords": [
      "magneto-acoustic technique",
      "bioelectric currents",
      "Lorentz force",
      "steady magnetic field",
      "acoustic signal",
      "non-invasive measurement",
      "saline",
      "tissue"
    ],
    "hubs": [],
    "raw": "{\n  \"study_type\": \"engineering\",\n  \"exposure\": {\n    \"band\": null,\n    \"source\": null,\n    \"frequency_mhz\": null,\n    \"sar_wkg\": null,\n    \"duration\": null\n  },\n  \"population\": null,\n  \"sample_size\": null,\n  \"outcomes\": [\n    \"Non-invasive measurement/detection of bioelectric currents using magneto-acoustic technique\",\n    \"Linear relationship between acoustic signal and current\",\n    \"Detection of microampere-level currents in saline and tissue\"\n  ],\n  \"main_findings\": \"A magneto-acoustic method is described for non-invasive measurement of bioelectric currents, based on Lorentz-force-induced vibrations in a steady magnetic field. An experimental setup detected microampere-level currents in saline and tissue, and results showed a linear relationship between acoustic signal and current.\",\n  \"effect_direction\": \"unclear\",\n  \"limitations\": [],\n  \"evidence_strength\": \"insufficient\",\n  \"confidence\": 0.74,\n  \"peer_reviewed_likely\": \"yes\",\n  \"keywords\": [\n    \"magneto-acoustic technique\",\n    \"bioelectric currents\",\n    \"Lorentz force\",\n    \"steady magnetic field\",\n    \"acoustic signal\",\n    \"non-invasive measurement\",\n    \"saline\",\n    \"tissue\"\n  ],\n  \"suggested_hubs\": []\n}"
  },
  "synthesis": null,
  "synthesisStatus": "pending",
  "originalHref": "https://pubmed.ncbi.nlm.nih.gov/17282874/",
  "sourceUrl": "https://rfsafe.org/mel/paper.php?id=3531",
  "updated": "2026-02-13 07:28:16"
}