A new Image Reconstruction Algorithm for Magnetic Resonance Electrical Impedance Tomography Using one Component of Measured Magnetic Field.

Wang Huixian, Wang Yuyu, Song Tao, He Yongbo

PAPERpubmedConference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference2005engineeringEffect: unclearEvidence: Insufficient

Abstract

In this paper, a new conductivity images reconstruction algorithm for Magnetic Resonance Electrical Impedance Tomography (MR-EIT) is proposed. The algorithm doesn't need to rotate mechanically the imaged object and can image the conductivity distribution of object at oblique slice. The proposed reconstruction algorithm in this paper is more applicable than other MR-EIT reconstruction algorithms using one component of magnetic flux density. It is not necessary that the main magnetic field is perpendicular to the imaging slice, and so can be used for permanent MRI scanners as well as superconductive MRI scanners.

AI evidence extraction

At a glance
Study type
engineering
Effect direction
unclear
Population
โ€”
Sample size
โ€”
Exposure
MRI (Magnetic Resonance Electrical Impedance Tomography)
Evidence strength
Insufficient
Confidence: 66% ยท Peer-reviewed: yes

Main findings

The paper proposes a new conductivity image reconstruction algorithm for MR-EIT that does not require mechanical rotation of the imaged object and can reconstruct conductivity distributions at an oblique slice. The approach is described as more applicable than other MR-EIT algorithms using one component of magnetic flux density and does not require the main magnetic field to be perpendicular to the imaging slice.

Outcomes measured

  • conductivity image reconstruction algorithm for MR-EIT
  • ability to reconstruct conductivity distribution without mechanical rotation
  • imaging at oblique slice using one component of magnetic flux density
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": null,
    "source": "MRI (Magnetic Resonance Electrical Impedance Tomography)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "conductivity image reconstruction algorithm for MR-EIT",
    "ability to reconstruct conductivity distribution without mechanical rotation",
    "imaging at oblique slice using one component of magnetic flux density"
  ],
  "main_findings": "The paper proposes a new conductivity image reconstruction algorithm for MR-EIT that does not require mechanical rotation of the imaged object and can reconstruct conductivity distributions at an oblique slice. The approach is described as more applicable than other MR-EIT algorithms using one component of magnetic flux density and does not require the main magnetic field to be perpendicular to the imaging slice.",
  "effect_direction": "unclear",
  "limitations": [],
  "evidence_strength": "insufficient",
  "confidence": 0.66,
  "peer_reviewed_likely": "yes",
  "keywords": [
    "MR-EIT",
    "Magnetic Resonance Electrical Impedance Tomography",
    "image reconstruction",
    "conductivity imaging",
    "magnetic flux density",
    "MRI scanners"
  ],
  "suggested_hubs": [
    {
      "slug": "engineering",
      "weight": 0.78,
      "reason": "Focuses on an image reconstruction algorithm for MR-EIT/MRI rather than health effects."
    }
  ]
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 3534

A new Image Reconstruction Algorithm for Magnetic Resonance Electrical Impedance Tomography Using one Component of Measured Magnetic Field. ยท Non-native EMF