Share

Simulation and Analysis of 2D Magnetic Field of Capsule Endoscope.

Li Jianping, Li Guoli, Wang Qunjing

PAPERpubmedConference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual Conference2005engineeringEffect: unclearEvidence: Insufficient

Abstract

2D magnetic field of a device used in the micropump of capsule endoscope is analyzed and calculated. Magnetic torque is simulated when the coils and permanent magnet are in different relative positions. The torque is calculated too when strength of external rotational magnetic field is changed. Corresponding results provide theoretical guide to the design and development of device.

AI evidence extraction

At a glance
Study type
engineering
Effect direction
unclear
Population
—
Sample size
—
Exposure
capsule endoscope micropump device (coils, permanent magnet, external rotational magnetic field)
Evidence strength
Insufficient
Confidence: 74% · Peer-reviewed: unknown

Main findings

The paper reports simulated and calculated 2D magnetic fields and magnetic torque for a capsule endoscope micropump device under different coil/magnet positions and different strengths of an external rotational magnetic field, intended to guide device design.

Outcomes measured

  • 2D magnetic field analysis/calculation
  • Magnetic torque simulation under varying relative positions of coils and permanent magnet
  • Magnetic torque calculation under varying strength of external rotational magnetic field

Limitations

  • No biological/health outcomes described in the abstract
  • No quantitative exposure parameters (e.g.
  • frequency
  • field strength values) reported in the abstract
  • Simulation/calculation context only
  • experimental validation not described in the abstract
View raw extracted JSON
{
  "study_type": "engineering",
  "exposure": {
    "band": null,
    "source": "capsule endoscope micropump device (coils, permanent magnet, external rotational magnetic field)",
    "frequency_mhz": null,
    "sar_wkg": null,
    "duration": null
  },
  "population": null,
  "sample_size": null,
  "outcomes": [
    "2D magnetic field analysis/calculation",
    "Magnetic torque simulation under varying relative positions of coils and permanent magnet",
    "Magnetic torque calculation under varying strength of external rotational magnetic field"
  ],
  "main_findings": "The paper reports simulated and calculated 2D magnetic fields and magnetic torque for a capsule endoscope micropump device under different coil/magnet positions and different strengths of an external rotational magnetic field, intended to guide device design.",
  "effect_direction": "unclear",
  "limitations": [
    "No biological/health outcomes described in the abstract",
    "No quantitative exposure parameters (e.g., frequency, field strength values) reported in the abstract",
    "Simulation/calculation context only; experimental validation not described in the abstract"
  ],
  "evidence_strength": "insufficient",
  "confidence": 0.74,
  "peer_reviewed_likely": "unknown",
  "keywords": [
    "capsule endoscope",
    "micropump",
    "magnetic field",
    "magnetic torque",
    "simulation",
    "coils",
    "permanent magnet",
    "external rotational magnetic field"
  ],
  "suggested_hubs": []
}

AI can be wrong. Always verify against the paper.

AI-extracted fields are generated from the abstract/metadata and may be incomplete or incorrect. This content is for informational purposes only and is not medical advice.

Comments

Log in to comment.

No comments yet.

NNEMF synthesis

Synthesis pending.

Original record: rfsafe.org paper 3544

Simulation and Analysis of 2D Magnetic Field of Capsule Endoscope. · Non-native EMF